In this paper, firstly a review is presented on our previous study of void fraction for adiabatic gas-liquid two-phase flows in horizontal microchannels. Water/nitrogen gas and/or ethanol-water-solution/nitrogen gas were pumped through circular microchannels of 50, 75, 100, 176, 251 and 530 μm in diameter. The concentration of ethanol in water was varied to change the surface tension and the liquid viscosity. The void fraction data for the 50 to 100 μm diameter channels showed non-linear variation against a homogenous void fraction, but the data for 251 and 530 μm diameter channels varied linearly with the homogeneous void fraction. Secondly, the data have been compared with the predictions of various correlations usually applied to mini/micro-channels as well as conventional size channels. Since no correlation could predict well all of our data, a new correlation has been proposed based on our data. It was found that the calculated void fraction by the proposed correlation agreed with all the data within 0.1, irrespective of channel diameters and the liquid properties.
1 January 1996 in Chemical Engineering Communications
We propose a practical method for the treatment of turbulent mixing rate in a two-phase subchannel flow in a hydrodynamic non-equilibrium state. Based on the assumption that the fundamental modes of the inter-subchannel fluid transfer in such a state are turbulent mixing, void drift, and diversion cross flow, the turbulent mixing rate is considered to be equal to that in the hydrodynamic equilibrium state that the flow will attain. The applicability of the method is examined by experiments concerning the axial variation in tracer concentration in a non-equilibrium flow without diversion cross flow. A good agreement is seen between the calculations and the measurements.
The flow characteristics of the single-phase liquid and the gas–liquid two-phase flows including the Newtonian and non-Newtonian liquids were experimentally investigated in a horizontal rectangular micro-channel with a sudden contraction—specifically the pressure change across the contraction. The rectangular cross-sectional dimension has Wu × Hu (width × height) = 0.99 × 0.50 mm2 on the upstream side of the contraction and Wd × Hd = 0.49 × 0.50 mm2 on the downstream side. The resulting contraction ratio, σA (=Wd/Wu), was 0.5. Air was used as the test gas (in the case of the gas–liquid two-phase flow experiment), distilled water and three kinds of aqueous solution, i.e., glycerin 25 wt%, xanthangum 0.1 wt% and polyacrylamide 0.11 wt% were used as the test liquid. The pressure distribution in the flow direction upstream and downstream of the channel was measured. The pressure change and loss at the sudden contraction were determined from the pressure distribution. In addition, the pressure change data were compared with the calculation by several correlations proposed by various researchers as well as a newly developed correlation in this study. From the comparisons, it was found that calculations by the newly developed correlations agreed well with the measured values within the error of 30%.
As an important structure of microfluidic devices, microchannels have the advantages of precise flow control and high reaction efficiency. This study investigates experimentally changing the rheological properties of a polyacrylamide (PAM) aqueous solution after flowing through a square microchannel with a hydraulic diameter of 0.5 mm under low Reynolds number and high shear rate conditions. To know the effect of the channel length on the change in viscosity and relaxation time, the length is changed to 100 mm and 200 mm. From the experiment, it is found that both the viscosity and relaxation time of the solution decrease with increasing the shear rate and the microchannel length. Based on the present experimental data, an empirical model is proposed to predict the change ratio of the relaxation time before and after passing through the microchannel, and the calculation with the model has an agreement with the experiment with root-mean-square absolute error of 0.007.
1 January 2000 in The proceedings of the JSME annual meeting
Various apparatuses made use of magnetic fluid, such as energy conversion systems, have been studied and developed in recent years. Accurate estimation of flow characteristics of vertical upward magnetic fluid-air two-phase flow in a small diameter tube is considered to be very important for the development. In this study, in order to find correlations applicable for the description of such characteristics, experiments have been conducted with a new test apparatus having 5 and 9 mm i.d. vertical pipes. A magnetic fluid, glycerin solution (the same viscosity as the magnetic fluid) and water were used as the test liquid while air as the test gas. In this paper, experimental results of main flow parameters, such as flow regime transition, frictional pressure drop and void fraction in two-phase flow have been presented and discussed to determine peculiar characteristics of magnetic fluid-air two-phase flow.