Haktan Altinova

Dr. Haktan Altinova

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2017 in European Journal of Medical Research
Verified
Journal Article
Open access
PDF file
ABAhmet Bozkurt
Ahmet Bozkurt
KCKristl G. Claeys
Kristl G. Claeys
SSSimone Schrading
Simone Schrading
JRJana V. Rödler
Jana V. Rödler
HAHaktan Altinova
Haktan Altinova
SNSabien G. A. van Neerven
Sabien G. A. van Neerven
Many new strategies for the reconstruction of peripheral nerve injuries have been explored for their effectiveness in supporting nerve regeneration. However only a few of these materials were actually clinically evaluated and approved for human use. This open, mono-center, non-randomized clinical study summarizes the 12-month follow-up of patients receiving reconstruction of the sural nerve biopsy defect by the collagen-based nerve guide Neuromaix. Neuromaix was implanted as a micro-structured, two-component scaffold bridging 20–40 mm nerve defects after sural nerve biopsy in twenty patients (eighteen evaluated, two lost in follow-up). Safety of the material was evaluated by clinical examination of wound healing. Performance was assessed by sensory testing of modalities, pain assessment, and palpation for the Hoffmann–Tinel’s sign as well as demarcating the asensitive area at each follow-up visit. Every patient demonstrated uneventful wound healing during the complete 12-month time course of the study. Two patients reported complete return of sensation, whereas eleven out of eighteen patients reported a positive Hoffmann–Tinel’s sign at the lower leg with simultaneous reduction of the asensitive area by 12 months. Our data show that Neuromaix can be implanted safely in humans to bridge sural nerve gaps. No procedure-related, adverse events, or severe adverse events were reported. These first clinical data on Neuromaix provide promising perspectives for the bridging of larger nerve gaps in combined nerves, which should be investigated more through extensive, multi-center clinical trials in the near future.

1 October 2014 in Brain Research
Verified
Journal Article
Closed access
HAHaktan Altinova
Haktan Altinova
SMSven Möllers
Sven Möllers
TFTobias Fuehrmann
Tobias Fuehrmann
RDRonald Deumens
Ronald Deumens
ABAhmet Bozkurt
Ahmet Bozkurt
GBGary A. Brook
Gary A. Brook

27 July 2015 in European Journal of Neuroscience
Verified
Journal Article
Closed access
PDF file
DHDorothee Hodde
Dorothee Hodde
JGJosé Gerardo-Nava
José Gerardo-Nava
VWVanessa Wöhlk
Vanessa Wöhlk
SWStefan Weinandy
Stefan Weinandy
SJStefan Jockenhoevel
Stefan Jockenhoevel
GBGary Anthony Brook
Gary Anthony Brook

4 February 2019 in Regenerative Biomaterials
Verified
Journal Article
Open access
PDF file
HAHaktan Altinova
Haktan Altinova
SHSebastian Hammes
Sebastian Hammes
MPMoniek Palm
Moniek Palm
JGJose Gerardo-Nava
Jose Gerardo-Nava
PAPascal Achenbach
Pascal Achenbach
GBGary Anthony Brook
Gary Anthony Brook
Severe traumatic spinal cord injury (SCI) results in a devastating and permanent loss of function, and is currently an incurable condition. It is generally accepted that future intervention strategies will require combinational approaches, including bioengineered scaffolds, to support axon growth across tissue scarring and cystic cavitation. Previously, we demonstrated that implantation of a microporous type-I collagen scaffold into an experimental model of SCI was capable of supporting functional recovery in the absence of extensive implant–host neural tissue integration. Here, we demonstrate the reactive host cellular responses that may be detrimental to neural tissue integration after implantation of collagen scaffolds into unilateral resection injuries of the adult rat spinal cord. Immunohistochemistry demonstrated scattered fibroblast-like cell infiltration throughout the scaffolds as well as the presence of variable layers of densely packed cells, the fine processes of which extended along the graft–host interface. Few reactive astroglial or regenerating axonal profiles could be seen traversing this layer. Such encapsulation-type behaviour around bioengineered scaffolds impedes the integration of host neural tissues and reduces the intended bridging role of the implant. Characterization of the cellular and molecular mechanisms underpinning this behaviour will be pivotal in the future design of collagen-based bridging scaffolds intended for regenerative medicine.

1 January 2020 in Biomedical Materials
Verified
Journal Article
Closed access
PDF file
HAHaktan Altinova
Haktan Altinova
SHSebastian Hammes
Sebastian Hammes
MPMoniek Palm
Moniek Palm
PAPascal Achenbach
Pascal Achenbach
JGJose Gerardo-Nava
Jose Gerardo-Nava
GBGary A Brook
Gary A Brook
Severe spinal cord injury (SCI) results in permanent functional deficits, which despite pre-clinical advances, remain untreatable. Combinational approaches, including the implantation of bioengineered scaffolds are likely to promote significant tissue repair. However, this critically depends on the extent to which host tissue can integrate with the implant. In the present paper, blood vessel formation and maturation were studied within and around implanted micro-structured type-I collagen scaffolds at 10 weeks post implantation in adult rat mid-cervical spinal cord lateral funiculotomy injuries. Morphometric analysis revealed that blood vessel density within the scaffold was similar to that of the lateral white matter tracts that the implant replaced. However, immunohistochemistry for zonula occludens −1 (ZO-1) and endothelial barrier antigen revealed that scaffold microvessels remained largely immature, suggesting poor blood-spinal cord barrier (BSB) reformation. Furthermore, a band of intense ZO-1-immunoreactive fibroblast-like cells isolated the implant. Spinal cord vessels outside the ZO-1-band demonstrated BSB-formation, while vessels within the scaffold generally did not. The formation of a double-layered fibrotic and astroglial scar around the collagen scaffold might explain the relatively poor implant-host integration and suggests a mechanism for failed microvessel maturation. Targeted strategies that improve implant-host integration for such biomaterials will be vital for future tissue engineering and regenerative medicine approaches for traumatic SCI.

20 October 2016 in Tissue Engineering and Regenerative Medicine
Verified
Journal Article
Closed access
PDF file
HAHaktan Altinova
Haktan Altinova
SMSven Möllers
Sven Möllers
RDRonald Deumens
Ronald Deumens
JGJose Gerardo-Nava
Jose Gerardo-Nava
TFTobias Fuehrmann
Tobias Fuehrmann
GBGary Anthony Brook
Gary Anthony Brook