Ernia Susana

Mrs. Ernia Susana


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 January 2022 in Information
Verified
Journal Article
Open access
PDF file
ESErnia Susana
Ernia Susana
Kalamullah RamliKalamullah Ramli
Kalamullah Ramli
Hendri MurfiHendri Murfi
Hendri Murfi
NANursama Heru Apriantoro
Nursama Heru Apriantoro
Monitoring systems for the early detection of diabetes are essential to avoid potential expensive medical costs. Currently, only invasive monitoring methods are commercially available. These methods have significant disadvantages as patients experience discomfort while obtaining blood samples. A non-invasive method of blood glucose level (BGL) monitoring that is painless and low-cost would address the limitations of invasive techniques. Photoplethysmography (PPG) collects a signal from a finger sensor using a photodiode, and a nearby infrared LED light. The combination of the PPG electronic circuit with artificial intelligence makes it possible to implement the classification of BGL. However, one major constraint of deep learning is the long training phase. We try to overcome this limitation and offer a concept for classifying type 2 diabetes (T2D) using a machine learning algorithm based on PPG. We gathered 400 raw datasets of BGL measured with PPG and divided these points into two classification levels, according to the National Institute for Clinical Excellence, namely, “normal” and “diabetes”. Based on the results for testing between the models, the ensemble bagged trees algorithm achieved the best results with an accuracy of 98%.

23 February 2023 in Information
Verified
Journal Article
Open access
PDF file
ESErnia Susana
Ernia Susana
Kalamullah RamliKalamullah Ramli
Kalamullah Ramli
PPPrima Dewi Purnamasari
Prima Dewi Purnamasari
NANursama Heru Apriantoro
Nursama Heru Apriantoro
Diabetes monitoring systems are crucial for avoiding potentially significant medical expenses. At this time, the only commercially viable monitoring methods that exist are invasive ones. Since patients are uncomfortable while blood samples are being taken, these techniques have significant disadvantages. The drawbacks of invasive treatments might be overcome by a painless, inexpensive, non-invasive approach to blood glucose level (BGL) monitoring. Photoplethysmography (PPG) signals obtained from sensor leads placed on specific organ tissues are collected using photodiodes and nearby infrared LEDs. Cardiovascular disease can be detected via photoplethysmography. These characteristics can be used to directly affect BGL monitoring in diabetic patients if PPG signals are used. The Guilin People’s Hospital’s open database was used to produce the data collection. The dataset was gathered from 219 adult respondents spanning an age range from 21 to 86 of which 48 percent were male. There were 2100 sampling points total for each PPG data segment. The methodology of feature extraction from data may assist in increasing the effectiveness of classifier training and testing. PPG data information is modified in the frequency domain by the instantaneous frequency (IF) and spectral entropy (SE) moments using the time–frequency (TF) analysis. Three different forms of raw data were used as inputs, and we investigated the original PPG signal, the PPG signal with instantaneous frequency, and the PPG signal with spectral entropy. According to the results of the model testing, the PPG signal with spectral entropy generated the best outcomes. Compared to decision trees, subspace k-nearest neighbor, and k-nearest neighbor, our suggested approach with the super vector machine obtains a greater level of accuracy. The super vector machine, with 91.3% accuracy and a training duration of 9 s, was the best classifier.

11 January 2022 in Teknik
Verified
Journal Article
Open access
PDF file
HKHeri Kuswoyo
Heri Kuswoyo
ESErnia Susana
Ernia Susana
HTHendrana Tjahjadi
Hendrana Tjahjadi
Silent hypoxia in Covid-19 patients and symptoms of severe hypoxemia require appropriate treatment. These cases often appear asymptomatic but risk fatal to life-threatening. One of the recommended devices is pulse oximetry. Embedded systems technologies and the Internet of Things (IoT) can develop low-cost personal health monitoring devices. This study developed a pulse oximetry prototype integrated with a digital temperature sensor and equipped with the interpretation results of both "normal" and "hypoxic" conditions. It is called OxyTemp. IoT technologies monitor user conditions remotely using the Blynk application via mobile phones. This study used Research & Development with the Reverse engineering method. The OxyTemp has Different types of prototype testing are physical and functional inspection, electrical safety testing, and performance testing of each parameter using an appropriate calibrator. The working method refers to SK Direktur Jenderal Pelayanan Kesehatan Tahun 2018 No. 041-18 on Pulse Oximeter Testing Working Methods.