Alpha-7 nicotinic acetylcholine receptor (α7-nAChR) agonists can prevent glutamate-induced excitotoxicity in cultured retinal ganglion cells (RGCs). However, the neuroprotective effects and the mechanism of action of PNU-282987, an α7-nAChR agonist, in a chronic in vivo rat glaucoma model are poorly understood. We found that elevated intraocular pressure (IOP) downregulated retinal α7-nAChR expression. Electroretinography revealed that the amplitude of the photopic negative response (PhNR) decreased in parallel with the loss of RGCs caused by elevated IOP. PNU-282987 enhanced RGC viability and function and decreased terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL)-positive signals in RGCs. Patch-clamp recordings revealed differences in the baseline frequencies and decay times of the miniature GABAergic inhibitory postsynaptic currents (mIPSCs) of RGCs between control and glaucomatous retinal slices. The results of western blotting and immunostaining showed that glutamic acid decarboxylase 65/67 and GABA deficits persisted in glaucomatous retinas and that these deficits were reversed by PNU-282987. Patch-clamp recordings also showed that PNU-282987 significantly increased the frequency and amplitude of the GABAergic mIPSCs of RGCs. The protective effects of PNU-292987 were blocked by intravitreal administration of selective GABAA receptor antagonists. The modulation of GABAergic synaptic transmission by PNU-282987 causes de-excitation of ganglion cell circuits and suppresses excitotoxic processes.
14 April 2023 in IEEE Transactions on Instrumentation and Measurement
It has been more than two years since the outbreak of COVID-19, which has spread to almost every corner of the world and killed a great number of people. Rapid detection and screening have become an important means of controlling the spread of COVID-19. Segmentation of COVID-19 infected tissue from computed tomography (CT) images of a patient’s lungs can provide clinicians with important information to quantify and diagnose COVID-19. However, the accuracy of medical image segmentation is seriously affected by such factors as the low contrast between the infected tissue and the edge of the surrounding environment, the large variation of the infected tissue and the lack of labeling data. Therefore, a deep learning model called CdcSegNet to accurately segment lung lesions from CT images infected by COVID-19 is proposed. In our method, transfer learning is introduced to solve the problem of lack of annotation data, and three modules, i.e., continuous dilated convolution module (CDC), parallel dual attention module (PDA) and additional multi-core pooling layer (AMP) are innovatively proposed to solve the problem of fuzzy segmentation boundary and to segment effectively infected tissues. Extensive experiments and comparison studies are made, and demonstrate that our model CdcSegNet has high accuracy in COVID-19 segmentation, and is superior to the state-of-the-art models in terms of DICE, SEN, SPE, PPV, and VOE.
11 September 2024 in Journal of Imaging Informatics in Medicine