weixiu shi

Prof. weixiu shi

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 March 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
NYNan Yang
Nan Yang
weixiu shiweixiu shi
weixiu shi
子周子宏 周
子宏 周
It has been proposed in China that the country should reach a “carbon peak” by 2030 and be “carbon neutral” by 2060. In the context of energy conservation and emission reduction, the country’s energy structure needs to be transformed to improve the technology level and more widespread consumption of renewable energy. The global renewable energy utilization situation is first analyzed in this study from the perspective of renewable energy and the buildings using it, highlighting the importance of the application of renewable energy in buildings. Secondly, from the perspective of solar energy utilization technology, ground source heat pump technology, and systems for managing energy use in buildings, the progressiveness of renewable energy applications in buildings is analyzed. The application of these technologies in buildings is demonstrated from various angles. Thirdly, the development prospect of buildings using renewable energy is discussed from the perspective of the promotion of renewable energy-powered buildings and green construction. The development prospects of buildings using renewable energy are discussed from the economic benefits of green finance, the promotion and social support of renewable energy, and the environmental benefits of green buildings. Finally, based on studies in the United States, the United Kingdom, Russia, and China, the international energy policy and development direction, as well as the evaluation criteria of green buildings, are discussed, along with an assessment system for green buildings that is complementary to the strategic agreement.

26 March 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
HMHaofan Mu
Haofan Mu
weixiu shiweixiu shi
weixiu shi
Due to the rapid development of science and technology in today’s era, electronic equipment is constantly upgrading. Today, the developmental trend of electronic equipment is miniaturization, portability and multi-functionality. However, multi-functionality often means multi-components, so it is undoubtedly a great test of heat dissipation ability to accommodate more components in a smaller volume. Without sufficient heat dissipation capacity, a large number of components will stop working or even be damaged because of the heat generated during operation. As a new passive cooling and heat exchange technology, pulsating heat pipes have many advantages, such as having no external energy input, a simple structure, changeable installation forms and low installation requirements. They have shown great potential in the field of thermal management, and have attracted a lot of scholars’ attention since they were put forward. Because of their operational stability and heat exchange ability in high heat flux environments, they are the best choice for cooling electronic equipment at present. If they can be fully studied and utilized, pulsating heat pipes can not only reduce the consumption of heat dissipation resources but also reuse heat energy to realize the sustainable utilization of resources. This paper briefly introduces the demand background and structural principle of pulsating heat pipes, and summarizes the research on the parameters of pulsating heat pipes and the application status of pulsating heat pipes. The parameters involve working fluid type, pipe diameter, elbow number, liquid filling rate, inclination angle, etc. After classifying the parameters that affect the operation results of pulsating heat pipes, this paper summarizes the research at this stage, and points out the lack of research fields, such as heat flux density, and new application fields of unconventional gravity environment by combining the literature content with the current scientific and technological development trends and experimental parameters, such as thermodynamics.

20 August 2025 in Buildings
Verified
Journal Article
Open access
PDF file
weixiu shiweixiu shi
weixiu shi
HCHaiyu Chang
Haiyu Chang
JZJunwei Zhou
Junwei Zhou
BMBai Mu
Bai Mu
SQShuang Quan
Shuang Quan
LPLisheng Pan
Lisheng Pan
This review focuses on the advancements of CO2 transcritical cycle technology in building indoor environmental regulation, particularly in combined heating and cooling applications. The paper highlights the energy efficiency and environmental benefits of CO2 as a natural refrigerant, which has zero ozone depletion potential (ODP) and very low global warming potential (GWP). It provides a comprehensive overview of recent optimization strategies, including distributed compression, the integration of ejectors and expanders, and the design improvements of key components such as gas coolers, compressors, and throttling valves. Through optimization strategies such as dual-system cycles, this technology can achieve a COP improvement of 15.3–46.96% in heating scenarios; meanwhile, with the help of distributed compression technology, its cooling capacity can be enhanced by up to 26.5%. The review also examines various operating conditions such as discharge pressure and subcooling, which significantly affect system performance. The paper concludes by identifying the current challenges in the application of CO2 systems, such as high initial costs and system stability under extreme conditions, and suggests future research directions to overcome these limitations and improve the practical application of CO2 transcritical cycles in the building industry. Overall, it is concluded that the development of expander-compressors holds great potential for achieving better performance and represents a promising direction for future advancements in this field.

19 January 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
weixiu shiweixiu shi
weixiu shi
XLXuebing Liu
Xuebing Liu
XSXiaoyang Su
Xiaoyang Su
HCHongdi Chen
Hongdi Chen
LPLisheng Pan
Lisheng Pan
Pulsating heat pipe (PHP) is an efficient heat transfer technology applied in the fields of heat dissipation and energy utilization. There are many factors affecting the heat transfer of PHP, including working fluid, filling ratio, inclination angle, etc. The cooling capacity of the cooling water system at the condensing section to the working fluid is also an important factor affecting the starting and operating of PHP. The research on PHP at different cooling water flow rates is of great significance for enhancing the operating performance. An experimental investigation of starting and running performance is carried out on a closed loop PHP with ultrapure water under different inclination angles of 90°, 60° and 30°. The starting and heat transfer performance of PHP with a filling ratio of 50% is obtained by adjusting the heat input in the range of 30–210 W at different cooling water flow rates of 6.7 g/s, 9.7 g/s and 13.9 g/s. The temperature and heat transfer resistance are used for analyzing the heat transfer performance. The results show that the starting mode, initial pulsating temperature and different heat transfer effects are brought about by different cooling water flow rates. It is observed that the cooling water flow rate has no obvious influence on the starting mode of PHP and that the starting mode of PHP is temperature progressive, starting with the increase in cooling water flow rates at a heating input of about 30 W. The influence of cooling water flow rates on the heat transfer performance of PHP is affected in a different way by inclination angles. The heat transfer performance of PHP with an inclination angle of 90° is similar at 6.7 g/s, 9.7 g/s and 13.9 g/s but, under the condition of 60° and 30°, the heat transfer resistance drops within a certain range effectively with an increasing cooling water flow rate from 6.7 g/s to 9.7 g/s and the heat transfer performance does not change significantly with the cooling water flow rate increasing to 13.9 g/s. Thus, there is an optimal value for the cooling water flow rate during the operating of PHP. The inclination angle also has an important effect on the temperature pulsating, and the temperature of PHP affected by gravity is stable with an inclination angle of 90°. However, the reduced influence of gravity on the backflow of the working fluid drops when the inclination angle decreases from 90° to 30°, and the wall temperature increases due to local overheating when the high heat input occurs.

5 February 2024 in Journal of Building Engineering
Verified
Journal Article
Closed access
LPLisheng Pan
Lisheng Pan
YGYuan Guo
Yuan Guo
QYQuanying Yan
Quanying Yan
weixiu shiweixiu shi
weixiu shi

22 February 2019 in Energies
Verified
Journal Article
Open access
PDF file
weixiu shiweixiu shi
weixiu shi
LPLisheng Pan
Lisheng Pan
The organic Rankine cycle (ORC) is efficient in using low-grade heat energy, while low pump efficiency and high pump leakage are usually serious problems. A gravity-driven organic power cycle (GDOPC) uses gravity instead of a pump to pressurize working fluid and has the potential to avoid problems associated with the pump. A theoretical method is used to study the performance and suitability of several fluids for GDOPC. The results show that the flow efficiency in high vertical pipes and the pump efficiency determine whether GDOPC gives better performance than ORC or not. When R245fa is selected as working fluid and evaporating temperature is 62 °C, specific energy of GDOPC (flow efficiency is 80%) is 2.5% higher than that of ORC (pump efficiency is 60%). The improvement degree of specific energy and the liquid column height increase with increasing evaporating temperature. R1234yf and R227ea give good performance with specific energy of 4.84 kJ/kg and 4.82 kJ/kg, respectively, while they need a liquid column as much as 76.55 m and 45.65 m, respectively. Although R365mfc and cyclopentane do not give the most excellent cycle performance, they need liquid column height as low as 9.04 m and 10.88 m, respectively. Fluid with low saturated pressure and high density may need low liquid column height and has the advantage to be used in practical applications.