Model predictive control (MPC) suffers from high computational burden and cumbersome tuning of weighting factors especially for three-level three-phase inverters. Here a fast finite-switching-state model predictive control (FSS-MPC) algorithm without weighting factors is proposed. Firstly, the deadbeat (DB) solution is used to construct the voltage vector reference. Then, the T-type three-level three-phase inverter topology is selected and voltage vectors are carefully tuned in order to minimize the neutral-point (NP) voltage fluctuation. The voltage vectors that are far from the desired voltage vector reference and go against balancing the NP voltage are abandoned. Thus, only three effective voltage vectors instead of totally 27 vectors are required in the implementation of the proposed FSS-MPC algorithm, which saves computation time up to 46.7%. Furthermore, the proposed algorithm makes the tuning of the weighting factor unnecessary, which simplifies the practical implementation and improves the portability of the algorithm. Finally, an experimental prototype was established and main results including the steady-state and dynamic performance were presented to validate the effectiveness of the proposed algorithm.
Microgrids have emerged as a promising solution to integrate distributed energy resources (DERs) and supply reliable and efficient electricity. The operation of a microgrid involves the coordination of different DERs and loads. To date, various control methods have been developed to maximize the overall benefit while satisfying various constraints. Now it is urgently needed to understand and comprehend these approaches to further stimulate the deployment of microgrids. This paper presents an overview for researchers on economic model predictive control (EMPC) methods of microgrids to achieve a variety of objectives such as cost minimization and benefit maximization. The fundamental principle of the EMPC theory is explained in detail. The most popular and important strategies applied to stand-alone microgrids, grid-connected microgrids, residential smart homes, as well as networked microgrids are discussed. Future trends are also highlighted.
15 September 2020 in IEEE Transactions on Power Electronics
Dynamic performance of maximum power point tracking (MPPT) algorithms is important to ensure high power yield under practical operating conditions. In this paper, after reviewing three dynamic test procedures, including stepped oper- ation procedure, day-by-day operation procedure, and EN50530 dynamic test procedure, three typical MPPT algorithms such as the fixed-step-size perturb and observe (P&O), variable-step- size incremental conductance (VSSINC), and hybrid-step-size Beta method are evaluated experimentally under the EN 50530 dynamic test procedure. Two dynamic EN50530 test sequences are adopted for the performance evaluation to cover different irradiance changing conditions. The PV model for EN50530 dynamic test sequences is built and the effects of wrong-step changes by using three MPPT algorithms are analyzed systemat- ically. The experimental comparison of three MPPT algorithms in terms of the tracking routines, accumulated energy, and tracking efficiency is presented. The research shows that the 0.5% fixed- step-size P&O may fail to track the MPP due to the tracking drift while the beta algorithm exhibits the highest tracking efficiency under both dynamic sequences. The average tracking efficiency improvement of the beta algorithm compared with other two algorithms are experimentally measured as 24.2% and 18.8% respectively.
18 December 2020 in IEEE Transactions on Transportation Electrification
Efficiency and reliability are essential for isolated bidirectional dc-dc converters in electric vehicle (EV) battery charging systems. As one promising power interface between energy storage components and power bus, dual-active-bridge (DAB) dc-dc converters have gained wide applications due to the advantages of galvanic isolation, symmetric circuit structure, high power density, and easy control implementation. In this article, based on the triple-phase shift (TPS) control, a fast and effective fault diagnosis strategy is proposed for DAB converters to improve both the power conversion efficiency and reliability. First, the operation principle of DAB converters with TPS control is presented. Then, a fast and effective open-circuit fault (OCF) analysis under different operation modes of TPS control is presented. Based on the resonant phenomenon during the fault conditions, an OCF diagnosis strategy that uses midpoint voltage as diagnosis criteria is proposed for DAB converters under the advanced TPS control to identify the faulty devices quickly and avoid the system collapse. After the failure switches are located, fault-tolerant operation is adopted to maintain the power transmission ability of DAB converters and ensure safe operation. The experimental results are provided to validate the correctness and effectiveness of the OCF performance analysis, fault diagnosis, and tolerant method.
19 January 2022 in IEEE Transactions on Transportation Electrification
This article proposes an improved implicit model predictive current control (IMPCC) method for permanent magnet synchronous motor (PMSM) drives. Compared to the conventional implicit MPC, the proposed IMPCC has a much lower computational burden and thus is suitable for real-time applications. Two-step optimization is employed in this method to minimize the cost function based on continuous control set (CCS) while respecting the constraints. Furthermore, the proposed IMPCC uses an incremental model that eliminates the permanent magnet flux linkage. Its strong parameter robustness against stator resistance and inductance variations is also theoretically analyzed. Experimental results are presented to show the superior performance of the proposed IMPCC.
10 September 2018 in IEEE Transactions on Industrial Electronics
This paper presents a novel model predictive control (MPC) for the T-type single-phase three-level inverters. The cumbersome procedure in tuning of weighting factors is eliminated so that the implementation of the proposed MPC becomes easy. The constant switching frequency is achieved during the control implementation in order to facilitate the filter design. In order to optimize the distribution of the output current harmonics, multiple voltage vectors are employed in each control cycle with their application times setting inversely proportion to the respective cost function. The redundant small voltage vectors are utilized to balance the neutral point voltage of the inverter by directly regulating the upper and lower dc-link capacitors voltages. Finally, the proposed MPC algorithm is experimentally evaluated and compared with other two unfixed switching frequency MPC algorithms in terms of the steady state, transient performance and parameter sensitivity.