This study investigates the impact of roller blinds as an energy-saving strategy in a subtropical climate. Lighting control experiments were performed on west-facing and south-facing windows in the Subtropical Performance-Testbed for Innovative eNergy Research in Buildings Laboratory (SPINLab). This study accepts sunlight below 8000 lux and requires the indoor lighting of at least a reading of 500 lux. For the west-facing window experiment, the curtain energy-saving strategy implemented in this study resulted in 10% less energy consumption for air-conditioning and saved 90% of the lighting power consumption of the west facing window building. For the south-facing window experiment, we found that sunlight can fully supplement the lighting without adjusting the roller blinds because the window opening is different from the sunlight direction. In addition, the significant heat flux difference between the west-facing and south-facing windows experiments is also reflected in the energy consumption of the air conditioners.

13 March 2024 in Energies
Verified
Journal Article
Open access
PDF file
HHHsing-Yun Huang
Hsing-Yun Huang
WHWei-Chieh Hu
Wei-Chieh Hu
CCChun-Kuei Chen
Chun-Kuei Chen
TLTa-Hui Lin
Ta-Hui Lin
Feng-Yi LinFeng-Yi Lin
Feng-Yi Lin
PYPei-Yu Yu
Pei-Yu Yu
The objective of this study was to evaluate the effects of window films on indoor environmental conditions and electricity consumption of air conditioning. The research focused on the performance of different window films (HAG, RG), taking into account variations from different building orientations. The findings of this research indicated that building orientation could significantly influence the duration of direct sunlight entering the interior, with the areas closer to the glass being more susceptible to the effects of outdoor temperature and solar radiation. The clear glass with heat-absorbing film (HAG) and reflective film (RG) both reduced the indoor temperature and indoor illuminance while increasing indoor comfort. The RG could accumulate less heat on the glass surface compared with the HAG. The glass temperature of the RG will be lower than the HAG. The electricity-saving ratios of the HAG were 1.4%, 1.9%, 1.4%, and 1.2%, respectively, when facing the east, south, west, and northwest orientations compared with the clear glass (OG). The electricity-saving ratios of the RG were 3%, 4.2%, 4.2%, and 10.3%, respectively.

19 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
THTzu-Yang Hu
Tzu-Yang Hu
CCChun-Kuei Chen
Chun-Kuei Chen
WHWei-Chieh Hu
Wei-Chieh Hu
TLTa-Hui Lin
Ta-Hui Lin
Feng-Yi LinFeng-Yi Lin
Feng-Yi Lin
PYPei-Yu Yu
Pei-Yu Yu
Recently, energy saving has been a major issue in all aspects. In buildings, air conditioning is one major part of power consumption. In this study, we examined the effect of an intermittent control strategy for air conditioning on energy saving in western-exposed rooms under subtropical weather conditions. The strategy applied periodic deactivation and reactivation to the air conditioners. Room temperatures, power consumption, and readings from sensors of air conditioners of two identical rooms were monitored and analyzed. For indoor temperatures, we found that the deactivation of the air conditioner for 15 min resulted in temperature peaks that were 4 to 5 °C higher than the control room. The reactivation of the air conditioner was able to cool down the room within 10 min based on the built-in sensor. However, due to the location and resolution of the sensor, the overall temperature from the four temperature and humidity sensors was still higher than the target setting, which may cause thermal discomfort. For power consumption, the strategy led to power peaks while reactivating, but the summation was 2.9% lower.

13 May 2025 in Energies
Verified
Journal Article
Open access
PDF file
KYKuan-Ting Yeh
Kuan-Ting Yeh
WHWei-Chieh Hu
Wei-Chieh Hu
CCChun-Kuei Chen
Chun-Kuei Chen
TLTa-Hui Lin
Ta-Hui Lin
Feng-Yi LinFeng-Yi Lin
Feng-Yi Lin
PYPei-Yu Yu
Pei-Yu Yu
This study was conducted at SPINLab. The full-scale experiments were performed using two experimental spaces of identical specifications to investigate the effects of electrochromic film (OG + ECON or OG + ECOFF) on indoor environment and air conditioning electricity consumption in buildings with different orientations (East and West). The electricity-saving effects are more pronounced on the building’s west-facing side than on its east-facing side. For the east-facing side, the average electricity savings for OG + ECON and OG + ECOFF were 4.5%, and 5.1%, respectively. For the west-facing side, the average electricity savings increased to 9.2% and 9.4% for OG + ECON and OG + ECOFF. The research results on thermal comfort indicate (PMV) that applying electrochromic film (OG + ECON or OG + ECOFF) significantly improved indoor thermal comfort compared to using clear glass (OG) alone. The visual comfort analysis results indicate that the opaque (OG + ECOFF) and transparent (OG + ECON) states of electrochromic film could reduce daylight glare probability (DGP) values. However, due to the light-scattering properties of the liquid crystal droplets, the OG + ECOFF and OG + ECON states of the electrochromic film increased DGP values in 26.5% and 41.5% of the cases, respectively, when sunlight directly entered the interior.