Giovanni Maione

Mr. Giovanni Maione

Università di Catania
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2022 in Energies
Verified
Journal Article
Open access
PDF file
Giuseppe Marco TinaGiuseppe Marco Tina
Giuseppe Marco Tina
GMGiovanni Maione
Giovanni Maione
SLSebastiano Licciardello
Sebastiano Licciardello
Reliability and safety must be carefully considered in today’s power systems, which are rapidly evolving toward ever higher penetration of renewable, inverter-based generation units. Power systems are constantly stressed by active power disturbances, which can be exacerbated by wind and solar systems that are subject to rapid fluctuations in primary energy. In this framework, a comparative technical analysis of solutions to improve transient stability, both rotor angle stability and frequency stability, is carried out. These solutions can be adopted by the transmission system operator (e.g., an additional parallel transmission line), by the generation companies (e.g., a fast excitation system), or by both, such as SVC (static VAR compensator) and STATCOM (static synchronous compensator). Sensitivity analyses were carried out to assess the impact of the location of the wind turbines in the buses of the grid on their rated power and level of production. On the basis of these analyses, the worst-case fault was considered, and the critical fault recovery time was determined as an engineering parameter to compare the different solutions. For the numerical analysis, a modified IEEE 9-bus system was considered, and the PowerWorld software tool was used. Rotor angle and frequency stability analyses were performed.

21 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
Giuseppe Marco TinaGiuseppe Marco Tina
Giuseppe Marco Tina
GMGiovanni Maione
Giovanni Maione
DSDomenico Stefanelli
Domenico Stefanelli
Energy transition strategies point to energy systems that rely mostly on renewable sources, with photovoltaics being the most commonly used and emphasised. The transition from the past to the future of electrical system is characterised by the contrast between centralised and distributed generation, as well as the differences between synchronous machines and static converters and thus by their way to deliver services required for proper system operation, frequency regulation and transient stability. This paper compares the two converter control strategies, grid following and grid forming, for providing frequency regulation service while considering bulk photovoltaic generation at the HV level and MV-connected distributed by PV generation. The analyses reveal the equivalence between large plants and distributed resources for frequency regulation purposes, highlighting the relevance of grid-forming converter and their ability to supply inertia to the system. These results are obtained for the IEEE 14-bus system implemented in Dig Silent PowerFactory.

1 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Giuseppe Marco TinaGiuseppe Marco Tina
Giuseppe Marco Tina
GMGiovanni Maione
Giovanni Maione
SLSebastiano Licciardello
Sebastiano Licciardello
DSDomenico Stefanelli
Domenico Stefanelli
Power systems are rapidly evolving to face the increasing penetration of renewable inverter-based generation units and to improve their reliability and safety. A power system is constantly exposed to sudden changes or disturbances that may affect its stability. In this paper, a comparative analysis of solutions to improve transient stability, both rotor angle and frequency stability, is performed. These solutions are SVC, STATCOM, a fast excitation system, and an additional parallel transmission line. Sensitivity analyses were performed to evaluate the effects of the location of the three-phase fault line and the most effective SVC or STATCOM installation bus. Based on these analyses, the worst-case fault is considered, and the critical fault clearing time is determined as an engineering parameter for comparing the different solutions. For the numerical analysis, the IEEE 9 bus system is considered, and the PowerWorld software tool is used. Rotor angle and frequency stability analyses were performed. Moreover, specifically for SVC and STATCOM, the effects of different values of short-circuit ratios were considered in the context of rotor angle stability analysis. As part of the frequency stability analysis, the use of the remuneration for load shedding service in Italy was considered to perform an economic analysis for SVC and STATCOM.

23 December 2025 in Smart Grids and Sustainable Energy
Verified
Journal Article
Open access
PDF file
Giuseppe Marco TinaGiuseppe Marco Tina
Giuseppe Marco Tina
GMGiovanni Maione
Giovanni Maione
Cristina VenturaCristina Ventura
Cristina Ventura
The increasing integration of inverter-based resources (IBRs) for renewable energy sources (RESs) generation into power systems has a significant impact on their frequency transient behaviour. This is due to the variability and partially non-programmability of RES power generation and the lack of rotating inertia due to the use of static converters. This research work aims to analyse how frequency transients are affected by the increasing share of generation from RES, e.g. photovoltaics (PV), in the total generation, focusing on the types of inverters used as an interface with the grid, Grid Following (GFL) or Grid Forming (GFM) inverters. A quantitative analysis of the impact on the frequency transient of different GFM percentages on total IBR generation is provided. The study shows that a share of 50% of GFM inverter allows a frequency transient with a similar Nadir and still a higher Rate of Change of Frequency ( RoCoF ) of a system with only synchronous generators (SGs). The frequency-supporting actions of these technologies will be evaluated considering the periods of overgeneration, characterised by the need to cut PV production, creating a reserve of available but untapped energy.