Spectra of diatomic molecules are rich in fine structures which may be used for different analytical applications in high-resolution continuum source molecular absorption spectrometry (HR-CS MAS). If several bands of a given diatomic molecule are simultaneously measured, they may be used in multi-energy calibration (MEC), a method based on the use of several wavelengths of the same absorbing/emitting entity to improve the accuracy in analytical atomic spectrometry. In this work, MEC is used for the first time as a calibration method for HR-CS MAS using flame (F) and graphite furnace (GF) atomizers. Methods were developed and applied for the determination of N, P and S in fertilizers by HR-CS F MAS and Cl in milk by HR-CS GF MAS. Chlorine, N, P and S were measured via CaCl (10 band heads), NO (13 band heads), PO (13 band heads) and CS (14 band heads), respectively. No statistically significant differences were observed between Cl, N, P and S concentrations determined by MEC and by the conventional external standard calibration (paired t-test at a 95% confidence level, n = 3). Recoveries were in the 97–109% (Cl), 97–103% (P), 99–109% (S) and 98–99% (N) intervals, and the relative standard deviations (n = 12) for Cl, N, P, and S were typically 6%, 3%, 2% and 2%, respectively.
Rice is an important source of nutrition and energy consumed around the world. Thus, quality inspection is crucial for protecting consumers and increasing the rice’s value in the productive chain. Currently, methods for rice labeling depending on grain quality features are based on image and/or visual inspection. These methods have shown subjectivity and inefficiency for large-scale analyses. Laser-induced breakdown spectroscopy (LIBS) is an analytical technique showing attractive features due to how quick the analysis can be carried out and its capability of providing spectra that are true fingerprints of the sample’s elemental composition. In this work, LIBS performance was evaluated for labeling rice according to grain quality features. The LIBS spectra of samples with their grain quality numerically described as Type 1, 2, and 3 were measured. Several spectral processing methods were evaluated when modeling a k-nearest neighbors (k-NN) classifier. Variable selection was also carried out by principal component analysis (PCA), and then the optimal k-value was selected. The best result was obtained by applying spectrum smoothing followed by normalization by using the first fifteen principal components (PCs) as input variables and k = 9. Under these conditions, the method showed excellent performance, achieving sample classification with 94% overall prediction accuracy. The sensitivities ranged from 90 to 100%, and specificities were in the range of 92–100%. The proposed method has remarkable characteristics, e.g., analytical speed and analysis guided by chemical responses; therefore, the method is not susceptible to subjectivity errors.