Ros Wade

Mrs. Ros Wade

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2012 in Health Technology Assessment
Verified
Journal Article
Closed access
PDF file
CMC McKenna
C McKenna
RWRos Wade
Ros Wade
RFR Faria
R Faria
HYH Yang
H Yang
LSL Stirk
L Stirk
NWN Woolacott
N Woolacott
Background EOS is a biplane X-ray imaging system manufactured by EOS Imaging (formerly Biospace Med, Paris, France). It uses slot-scanning technology to produce a high-quality image with less irradiation than standard imaging techniques. Objective To determine the clinical effectiveness and cost-effectiveness of EOS two-dimensional (2D)/three-dimensional (3D) X-ray imaging system for the evaluation and monitoring of scoliosis and other relevant orthopaedic conditions. Data sources For the systematic review of EOS, electronic databases (MEDLINE, Allied and Complementary Medicine Database, BIOSIS Previews, Cumulative Index to Nursing and Allied Health Literature, The Cochrane Library, EMBASE, Health Management Information Consortium, Inspec, ISI Science Citation Index and PASCAL), clinical trials registries and the manufacturer’s website were searched from 1993 to November 2010. Review methods A systematic review of studies comparing EOS with standard X-ray [film, computed radiography (CR) or digital radiography] in any orthopaedic condition was performed. A narrative synthesis was undertaken. A decision-analytic model was developed to assess the cost-effectiveness of EOS in the relevant indications compared with standard X-ray and incorporated the clinical effectiveness of EOS and the adverse effects of radiation. The model incorporated a lifetime horizon to estimate outcomes in terms of quality-adjusted life-years (QALYs) and costs from the perspective of the NHS. Results Three studies met the inclusion criteria for the review. Two studies compared EOS with film X-ray and one study compared EOS with CR. The three included studies were small and of limited quality. One study used an earlier version of the technology, the Charpak system. Both studies comparing EOS with film X-ray found image quality to be comparable or better with EOS overall. Radiation dose was considerably lower with EOS: ratio of means for posteroanterior spine was 5.2 (13.1 for the study using the Charpak system); ratio of means for the lateral spine was 6.2 (15.1 for the study using the Charpak system). The study comparing EOS with CR found image quality to be comparable or better with EOS. Radiation dose was considerably lower with EOS than CR; ratio of means for the centre of the back was 5.9 and for the proximal lateral point 8.8. The lowest ratio of means was at the nape of the neck, which was 2.9. No other outcomes were assessed in the included studies, such as implications for patient management from the nature and quality of the image. Patient throughput is the major determinant of the cost-effectiveness of EOS. The average cost per procedure of EOS decreases with utilisation. Using estimates of patient throughput at national level from Hospital Episode Statistics data suggests that EOS is not cost-effective for the indications considered. Throughput in the region of 15,100 to 26,500 (corresponding to a workload of 60 to 106 patient appointments per working day) for EOS compared with a throughput of only 7530 for CR (30 patient appointments per working day) is needed to achieve an incremental cost-effectiveness ratio of £30,000 per QALY. EOS can be shown to be cost-effective only when compared with CR if the utilisation for EOS is about double the utilisation of CR. Limitations The main limitation of the systematic review of the clinical effectiveness of EOS was the limited number and quality of the data available. In particular, there were no studies assessing the potential health benefits arising from the quality and nature of the image, over and above those associated with reduced radiation exposure. Uncertainty in the model inputs was not fully explored owing to a lack of reporting of standard deviations or confidence intervals in the published literature for most of the parameters. As a result, uncertainty in the cost-effectiveness results was not presented. Conclusions Radiation dose is considerably lower with EOS than standard X-ray, whereas image quality remains comparable or better with EOS. However, the long-term health benefits from reduced radiation exposure with EOS are very small and there was a lack of data on other potential patient health benefits. The implications of any changes in the quality and nature of the EOS image compared with standard X-ray, for patient health outcomes, needs to be assessed. Given the higher cost of an EOS machine, utilisation is the major determinant of cost-effectiveness. Estimates of patient throughput at national level suggest that EOS is not cost-effective. Funding The National Institute for Health Research Health Technology Assessment programme.

19 August 2012 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
RWRos Wade
Ros Wade
HYHuiqin Yang
Huiqin Yang
CMClaire McKenna
Claire McKenna
RFRita Faria
Rita Faria
NGNigel Gummerson
Nigel Gummerson
NWNerys Woolacott
Nerys Woolacott

10 June 2013 in Research Synthesis Methods
Verified
Journal Article
Closed access
PDF file
RWRos Wade
Ros Wade
MCMark Corbett
Mark Corbett
AEAlison Eastwood
Alison Eastwood

18 January 2012 in BMC Medicine
Verified
Journal Article
Open access
PDF file
RPRobert S Phillips
Robert S Phillips
RWRos Wade
Ros Wade
Thomas LehrnbecherThomas Lehrnbecher
Thomas Lehrnbecher
LSLesley A Stewart
Lesley A Stewart
ASAlex J Sutton
Alex J Sutton
Febrile neutropenia is a frequently occurring and occasionally life-threatening complication of treatment for childhood cancer. Many biomarkers have been proposed as predictors of adverse events. We aimed to undertake a systematic review and meta-analysis to summarize evidence on the discriminatory ability of initial serum biomarkers of febrile neutropenic episodes in children and young people.

1 August 2013 in European Journal of Radiology
Verified
Journal Article
Closed access
RFRita Faria
Rita Faria
CMClaire McKenna
Claire McKenna
RWRos Wade
Ros Wade
HYHuiqin Yang
Huiqin Yang
NWNerys Woolacott
Nerys Woolacott
MSMark Sculpher
Mark Sculpher

1 November 2010 in European Journal of Cancer
Verified
Journal Article
Open access
BPBob Phillips
Bob Phillips
RWRos Wade
Ros Wade
LSLesley A. Stewart
Lesley A. Stewart
ASAlex J. Sutton
Alex J. Sutton
Febrile neutropaenia is a frequently occurring and occasionally life-threatening complication of treatment for childhood cancer, yet many children are aggressively over-treated. We aimed to undertake a systematic review and meta-analysis to summarise evidence on the discriminatory ability and predictive accuracy of clinical decision rules (CDR) of risk stratification in febrile neutropaenic episodes. The review was conducted in accordance with Centre for Reviews and Dissemination methods, using random effects models to undertake meta-analysis. It was registered with the HTA Registry of systematic reviews, CRD32009100453. We found 20 studies describing 16 different CDR assessed in 8388 episodes of FNP. No study compared different approaches and only one CDR had been subject to testing across multiple datasets. This review cannot conclude that any system is more effective or reliable than any other. To maximise the value of the information already collected by these and other cohorts of children with febrile neutropaenia, an individual-patient-data (IPD) meta-analysis is required to develop and test new and existing CDR to improve stratification and optimise therapy.