Jon Sporring

Prof. Dr. Jon Sporring

University of Copenhagen, Copenhagen, Hovedstaden, Denmark
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 May 2011 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
KMKeelin Murphy
Keelin Murphy
BGBram van Ginneken
Bram van Ginneken
JRJoseph M. Reinhardt
Joseph M. Reinhardt
SKSven Kabus
Sven Kabus
Kai DingKai Ding
Kai Ding
JPJosien P. W. Pluim
Josien P. W. Pluim
EMPIRE10 (Evaluation of Methods for Pulmonary Image REgistration 2010) is a public platform for fair and meaningful comparison of registration algorithms which are applied to a database of intra patient thoracic CT image pairs. Evaluation of nonrigid registration techniques is a nontrivial task. This is compounded by the fact that researchers typically test only on their own data, which varies widely. For this reason, reliable assessment and comparison of different registration algorithms has been virtually impossible in the past. In this work we present the results of the launch phase of EMPIRE10, which comprised the comprehensive evaluation and comparison of 20 individual algorithms from leading academic and industrial research groups. All algorithms are applied to the same set of 30 thoracic CT pairs. Algorithm settings and parameters are chosen by researchers expert in the con figuration of their own method and the evaluation is independent, using the same criteria for all participants. All results are published on the EMPIRE10 website (http://empire10.isi.uu.nl). The challenge remains ongoing and open to new participants. Full results from 24 algorithms have been published at the time of writing. This paper details the organization of the challenge, the data and evaluation methods and the outcome of the initial launch with 20 algorithms. The gain in knowledge and future work are discussed.

1 August 2010 in Medical Image Analysis
Verified
Journal Article
Closed access
PLPechin Lo
Pechin Lo
JSJon Sporring
Jon Sporring
HAHaseem Ashraf
Haseem Ashraf
JPJesper J.H. Pedersen
Jesper J.H. Pedersen
MBMarleen de Bruijne
Marleen de Bruijne

1 May 2012 in Medical Image Analysis
Verified
Journal Article
Closed access
VGVladlena Gorbunova
Vladlena Gorbunova
JSJon Sporring
Jon Sporring
PLPechin Lo
Pechin Lo
MLMartine Loeve
Martine Loeve
HTHarm A. Tiddens
Harm A. Tiddens
MBMarleen de Bruijne
Marleen de Bruijne

1 January 2013 in Lecture Notes in Computer Science
Verified
Book Chapter
Closed access
PDF file
HLHerve Lombaert
Herve Lombaert
JSJon Sporring
Jon Sporring
KSKaleem Siddiqi
Kaleem Siddiqi

1 December 2002 in ORL
Verified
Journal Article
Closed access
MSMads S. Sørensen
Mads S. Sørensen
ADAndy B. Dobrzeniecki
Andy B. Dobrzeniecki
PLPer Larsen
Per Larsen
TFThomas Frisch
Thomas Frisch
JSJon Sporring
Jon Sporring
TDTron A. Darvann
Tron A. Darvann
High-fidelity computer-based modeling, simulation and visualization systems for the study of temporal bone anatomy and training for middle ear surgery are based on a sequence of digital anatomical images, which must cover a large tissue volume and yet display details in high resolution and with high fidelity. However, the use of existing image libraries by independent developers of virtual models of the ear is limited by copyright protection and low image resolution. A fresh frozen human temporal bone was CT-scanned and serially sectioned at 25 µm and digital images of the block surface were recorded at 50- to 100-µm increments with a Light PhaseTM single-shot camera back attachment. A total of 605 images were recorded in 24-bit RGB resolution. After color correction and elimination of image size variation by differential cropping to 15.4 cm × 9.7 cm, all images were resampled to 3,078 × 1,942 pixels at a final resolution of 50 µm/pixel and stored as 605 one-Mb JPEG files together with a three-dimensional viewer. The resulting complete set of image data provides: (1) a source material suitable for generating computer models of the human ear; (2) a resource of high-quality digital images of anatomical cross sections from the human ear, and (3) a PC-based viewer of the temporal bone in three perpendicular planes of section.

24 June 2015 in Cytometry Part A
Verified
Journal Article
Open access
PDF file
IZIwona Ziomkiewicz
Iwona Ziomkiewicz
JSJon Sporring
Jon Sporring
TPThomas Günther Pomorski
Thomas Günther Pomorski
ASAlexander Schulz
Alexander Schulz
Many membrane proteins are not evenly distributed over the plasma membrane, but gathered in domains assumed to have a particular lipid composition. Using single molecule localization microscopy (SMLM) we have immunolocalized a glycosylphosphatidylinositol (GPI)‐anchor protein that labels nanodomains in a specialized plant cell type, and compared the suitability of three methods to estimate their size. As conventional methods full width at half maximum (FWHM) and the full diameter (FWMin) of domains were used. A boundary detection method of the domain area (DA) was performed in order to take irregular shapes into account. In order to compare the influence of the chosen measurement methods, we have developed a MatLab program that allows for automated analysis of domain sizes from multiple SMLM images and provides the statistics of three key features of domains: FWHM and FWMin along their long and short axes as well as the DA, derived from the molecular density. Domains formed by the GPI‐anchor protein are approximating elliptical shapes. Direct and indirect immunolabeling resulted in a statistically significant difference in apparent domain size, reflecting the fact that the secondary antibody molecules extend the uncertainty along the nanodomain border. FWMin values along the long and short axis give good estimates of regular, geometrically centred domain shapes, while the DA value matches regular as well as irregular shapes best, as derived from computer‐generated, irregular point clusters. © 2015 International Society for Advancement of Cytometry