Background: The Gustilo classification is the most established system for classifying open fractures. Despite this, the classification has changed in how it has been described and interpreted. We have traced how this classification has slowly evolved throughout the literature over the past 4 decades. Methods: A systematic search of the literature was undertaken with the MEDLINE, Embase, and PubMed databases to source relevant articles that have evolved the interpretation of the Gustilo classification. The references from these articles were consecutively hand-searched to find other articles that describe the Gustilo classification. Results: There was a total of 393 results from the Healthcare Databases Advanced Search (HDAS): 95 from MEDLINE, 49 from Embase, and 249 from PubMed. Fifty-six articles were initially selected; an additional 67 articles were retrieved through reference checking and further checking of relevant articles until no additional relevant articles could be found. Conclusions: The original Gustilo and Anderson classification initially was modified by Gustilo before subtle changes were made to the descriptors in the 1990s. Some authors have used the Gustilo classification to create alternative classifications, but these have not gained traction. Other contemporaneous literature has modified the Gustilo-IIIB subtypes to better stratify functional and reconstructive outcomes following vascular injury. The impact and longevity of such recent modifications are yet to be known.
1 August 2017 in Journal of Plastic, Reconstructive & Aesthetic Surgery
Surgical site infection represents a large burden of care in the National Health Service. Current methods for diagnosis include a subjective clinical assessment and wound swab culture that may take several days to return a result. Both techniques are potentially unreliable and result in delays in using targeted antibiotics. Volatile organic compounds (VOCs) are produced by micro-organisms such as those present in an infected wound. This study describes the use of a device to differentiate VOCs produced by an infected wound vs. colonised wound. Malodourous wound dressings were collected from patients, these were a mix of post-operative wounds and vascular leg ulcers. Wound microbiology swabs were taken and antibiotics commenced as clinically appropriate. A control group of soiled, but not malodorous wound dressings were collected from patients who had a split skin graft (SSG) donor site. The analyser used was a G.A.S. GC-IMS. The results from the samples had a sensitivity of 100% and a specificity of 88%, with a positive predictive value of 90%. An area under the curve (AUC) of 91% demonstrates an excellent ability to discriminate those with an infected wound from those without. VOC detection using GC-IMS has the potential to serve as a diagnostic tool for the differentiation of infected and non-infected wounds and facilitate the treatment of wound infections that is cost effective, non-invasive, acceptable to patients, portable, and reliable.
Notable advancements have been achieved in providing amputees with sensation through invasive and non-invasive haptic feedback systems such as mechano-, vibro-, electro-tactile and hybrid systems. Purely mechanical-driven feedback approaches, however, have been little explored. In this paper, we now created a haptic feedback system that does not require any external power source (such as batteries) or other electronic components. The system is low-cost, lightweight, adaptable and robust against external impact (such as water). Hence, it will be sustainable in many aspects. We have made use of latest multi-material 3D printing technology (Stratasys Objet500 Connex3) being able to fabricate a soft sensor and a mechano-tactile feedback actuator made of a rubber (TangoBlack Plus) and plastic (VeroClear) material. When forces are applied to the fingertip sensor, fluidic pressure inside the system acts on the membrane of the feedback actuator resulting in mechano-tactile sensation. We present the design, fabrication and validation of the proposed haptic feedback system. Our 7 mm-diameter feedback actuator is able to transmit a force range between 0.2 N (the median touch threshold) and 2.1 N (the maximum force transmitted by the feedback actuator at a 3 mm indentation) corresponding to force range exerted to the sensor of $1.2 - 18.49$ N.
Water content of the skin is an important parameter for controlling the penetration rate of chemicals through the skin barrier; therefore, for transdermal patches designed for drug delivery to be successful, the effects of the patches on the water content of the skin must be understood. Terahertz (THz) spectroscopy is a technique which is being increasingly investigated for biomedical applications due to its high sensitivity to water content and non-ionizing nature. In this study, we used THz measurements of the skin (in vivo) to observe the effect of partially and fully occlusive skin patches on the THz response of the skin after the patches had been applied for 24 h. We were able to observe an increase in the water content of the skin following the application of the patches and to identify that the skin remained hyper-hydrated for four hours after the removal of the fully occlusive patches. Herein, we show that THz spectroscopy has potential for increasing the understanding of how transdermal patches affect the skin, how long the skin takes to recover following patch removal, and what implications these factors might have for how transdermal drug patches are designed and used.