André Cavalheiro

Dr. André Cavalheiro


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2025 in Ultrasonics
Verified
Journal Article
Closed access
TOTimoteo F. de Oliveira
Timoteo F. de Oliveira
ACAndré Cavalheiro
André Cavalheiro
FBFlávio Buiochi
Flávio Buiochi
Marcos TsuzukiMarcos Tsuzuki
Marcos Tsuzuki
JLJosé P. Leão-Neto
José P. Leão-Neto
JAJose Henrique Andrade
Jose Henrique Andrade

25 July 2025 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
TOTimóteo F. Oliveira
Timóteo F. Oliveira
ASAgesinaldo Matos Silva
Agesinaldo Matos Silva
LPLuiz Octavio Pereira
Luiz Octavio Pereira
ACAndré Cavalheiro
André Cavalheiro
FBFlávio Buiochi
Flávio Buiochi
Marcos TsuzukiMarcos Tsuzuki
Marcos Tsuzuki

22 December 2021 in Machines
Verified
Journal Article
Open access
PDF file
ACAndré Cavalheiro
André Cavalheiro
DFDiolino José Santos Filho
Diolino José Santos Filho
JDJônatas C. Dias
Jônatas C. Dias
AAAron J. P. Andrade
Aron J. P. Andrade
Jose Roberto CardosoJose Roberto Cardoso
Jose Roberto Cardoso
Marcos TsuzukiMarcos Tsuzuki
Marcos Tsuzuki
In patients with severe heart disease, the implantation of a ventricular assist device (VAD) may be necessary, especially in patients with an indication for heart transplantation. For this, the Institute Dante Pazzanese of Cardiology (IDPC) has developed an implantable centrifugal blood pump that will be able to help a diseased human heart to maintain physiological blood flow and pressure. This device will be used as a totally or partially implantable VAD. Therefore, performance assurance and correct specification of the VAD are important factors in achieving a safe interaction between the device and the patient’s behavior or condition. Even with reliable devices, some failures may occur if the pumping control does not keep up with changes in the patient’s behavior or condition. If the VAD control system has no fault tolerance and no system dynamic adaptation that occurs according to changes in the patient’s cardiovascular system, a number of limitations can be observed in the results and effectiveness of these devices, especially in patients with acute comorbidities. This work proposes the application of a mechatronic approach to this class of devices based on advanced control, instrumentation, and automation techniques to define a method to develop a hierarchical supervisory control system capable of dynamically, automatically, and safely VAD control. For this methodology, concepts based on Bayesian networks (BN) were used to diagnose the patient’s cardiovascular system conditions, Petri nets (PN) to generate the VAD control algorithm, and safety instrumented systems to ensure the safety of the VAD system.