Muhammad Mahadi Abdul Jamil

Dr. Muhammad Mahadi Abdul Jamil


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2012
Verified
Conference Paper
Closed access
JSJ. M. Sharif
J. M. Sharif
MMM. F. Miswan
M. F. Miswan
MNMd Asri Ngadi
Md Asri Ngadi
SSSah Hj Salam
Sah Hj Salam
MJMuhammad Mahadi Abdul Jamil
Muhammad Mahadi Abdul Jamil
Image segmentation is the most important step and a key technology in image processing which directly affect the next processing. In human blood cell segmentation cases, many methods were applied for obtaining better results. It is basically an improved visualization to observe blood cell under blood smear process. This paper will present an approach for red blood cell (RBC) segmentation which is a part of study to perform automated counting for RBC. The methods involve are Ycbcr color conversion, masking, morphological operators and watershed algorithm. The combination of Ycbcr color conversion and morphological operator produce segmented white blood cell (WBC) nucleus. Then it is being used as a mask to remove WBC from the blood cell image. Morphological operators involve binary erosion diminish small object like platelet. The resulted RBC segmentation is passing through marker controlled watershed algorithm which handles overlapping cells. The improvement need to be done for both segmentation and overlapped cell handling to obtain better result in the future.

1 January 2014 in Procedia Computer Science
Verified
Journal Article
Open access
RTRazali Tomari
Razali Tomari
WZWan Nurshazwani Wan Zakaria
Wan Nurshazwani Wan Zakaria
MJMuhammad Mahadi Abdul Jamil
Muhammad Mahadi Abdul Jamil
FNFaridah Mohd Nor
Faridah Mohd Nor
NFNik Farhan Nik Fuad
Nik Farhan Nik Fuad
In vitro identification and counting of red blood cells (RBCs) is very important to diagnose blood related diseases such as malaria and anemia before a proper treatment can be proposed. The conventional practice for such procedure is executed manually by pathologist under light microscope. However, manual visual inspection is laborious task and depends on subjective assessment which leads to variation in the RBC identification and counting. In this paper a computer-aided systems is proposed to automate the process of detection and identification of RBC from blood smear image. Initially RBCs region are extracted from the background by using global threshold method applied on green channel color image. Next, noise and holes in the RBCs are abolished by utilizing morphological filter and connected component labeling. Following that, information from the RBCs’ are extracted based on its geometrical properties. Eventually, the RBCs were classified as normal/abnormal by using Artificial Neural Network (ANN) classifier. The proposed method has been tested on blood cell images and demonstrates a reliable and effective system for classifying normal and abnormal RBC

1 October 2008 in Journal of Structural Biology
Verified
Journal Article
Closed access
MJMuhammad Mahadi Abdul Jamil
Muhammad Mahadi Abdul Jamil
MDM.C.T. Denyer
M.C.T. Denyer
Mansour YouseffiMansour Youseffi
Mansour Youseffi
SBS.T. Britland
S.T. Britland
SLS. Liu
S. Liu
JZJ. Zhang
J. Zhang

1 January 2017 in Procedia Computer Science
Verified
Journal Article
Open access
Yoosuf NizamYoosuf Nizam
Yoosuf Nizam
MMMohd Norzali Hj Mohd
Mohd Norzali Hj Mohd
MJMuhammad Mahadi Abdul Jamil
Muhammad Mahadi Abdul Jamil
Fall detection and notification systems play an important role in our daily life, since human fall is a major health concern for many communities in today's aging population. There are different approaches used in developing human fall detection systems for elderly and people with special needs such as disable. The three basic approaches include some sort of wearable, non-wearable ambient sensor and vision based systems. This paper proposes a human fall detection system based on the velocity and position of the subject, extracted from Microsoft Kinect Sensor. Initially the subject and floor plane are extracted and tracked frame by frame. The tracked joints of the subject are then used to measure the velocity with respect to the previous location. Fall detection is confirmed using the position of the subject to see if all the joints are on the floor after an abnormal velocity. From the experimental results obtained, our system was able to achieve an average accuracy of 93.94% with a sensitivity of 100% and specificity of 91.3%.

5 February 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
ZSZakarya Farea Shaaf
Zakarya Farea Shaaf
MJMuhammad Mahadi Abdul Jamil
Muhammad Mahadi Abdul Jamil
RARadzi Ambar
Radzi Ambar
AHMED ABDU ALATTABAHMED ABDU ALATTAB
AHMED ABDU ALATTAB
AYAnwar Ali Yahya
Anwar Ali Yahya
YAYousef Asiri
Yousef Asiri
Background: Left ventricle (LV) segmentation using a cardiac magnetic resonance imaging (MRI) dataset is critical for evaluating global and regional cardiac functions and diagnosing cardiovascular diseases. LV clinical metrics such as LV volume, LV mass and ejection fraction (EF) are frequently extracted based on the LV segmentation from short-axis MRI images. Manual segmentation to assess such functions is tedious and time-consuming for medical experts to diagnose cardiac pathologies. Therefore, a fully automated LV segmentation technique is required to assist medical experts in working more efficiently. Method: This paper proposes a fully convolutional network (FCN) architecture for automatic LV segmentation from short-axis MRI images. Several experiments were conducted in the training phase to compare the performance of the network and the U-Net model with various hyper-parameters, including optimization algorithms, epochs, learning rate, and mini-batch size. In addition, a class weighting method was introduced to avoid having a high imbalance of pixels in the classes of image’s labels since the number of background pixels was significantly higher than the number of LV and myocardium pixels. Furthermore, effective image conversion with pixel normalization was applied to obtain exact features representing target organs (LV and myocardium). The segmentation models were trained and tested on a public dataset, namely the evaluation of myocardial infarction from the delayed-enhancement cardiac MRI (EMIDEC) dataset. Results: The dice metric, Jaccard index, sensitivity, and specificity were used to evaluate the network’s performance, with values of 0.93, 0.87, 0.98, and 0.94, respectively. Based on the experimental results, the proposed network outperforms the standard U-Net model and is an advanced fully automated method in terms of segmentation performance. Conclusion: This proposed method is applicable in clinical practice for doctors to diagnose cardiac diseases from short-axis MRI images.

13 July 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Yoosuf NizamYoosuf Nizam
Yoosuf Nizam
MMMohd Norzali Hj Mohd
Mohd Norzali Hj Mohd
MJMuhammad Mahadi Abdul Jamil
Muhammad Mahadi Abdul Jamil
Unintentional falls are a major public health concern for many communities, especially with aging populations. There are various approaches used to classify human activities for fall detection. Related studies have employed wearable, non-invasive sensors, video cameras and depth sensor-based approaches to develop such monitoring systems. The proposed approach in this study uses a depth sensor and employs a unique procedure which identifies the fall risk levels to adapt the algorithm for different people with their physical strength to withstand falls. The inclusion of the fall risk level identification, further enhanced and improved the accuracy of the fall detection. The experimental results showed promising performance in adapting the algorithm for people with different fall risk levels for fall detection.