mohammad Ayasrah

Dr. mohammad Ayasrah


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2024 in Vascular Health and Risk Management
Verified
Journal Article
Open access
PDF file
IQIzzeddin Qtaish
Izzeddin Qtaish
MAmohammad Ayasrah
mohammad Ayasrah
NQNoat R Qtaish
Noat R Qtaish
Background: Differences in dominance and stenosis in the complex vertebral artery (VA) network pose challenges in diagnosing and treating cerebrovascular diseases crucial for brain nutrition. This research examines these intricacies, highlighting the importance of detailed diagnosis and treatment methods. Objective: To analyze the prevalence of the dominant VA, evaluate the influence of gender and age on steno-occlusion, and explore the correlation between the dominant VA and stenosed VA segments. Methods: A retrospective study of 249 angiograms from patients with VA stenosed at King Abdullah University Hospital between August 2019 and December 2022. The patients presenting symptoms of vertigo, migraines, headaches, or transient ischemic attacks (TIA) were included, 182 cases were classified based on VA dominance and stenosis severity. The data were analyzed using IBM SPSS 27. Results: Out of the 182 participants, 64.8% were male, with an average age of 61.3 years and 35.2% were female. The prevalence of stenosis was distributed as follows: 26.4% mild, 44.0% moderate, and 29.7% severe. Statistically significant correlations were observed between hypertension, smoking, hyperlipidemia, and the degree of stenosis (p < 0.05), but not with diabetes. The prevalence of left vertebral artery (VA) dominance was found to be 41.1%. Additionally, there was no gender connection observed in the distribution of steno-occlusion (p = 0.434). There is no notable correlation between the degree of stenosis and the dominant vertebral artery (p > 0.05). Conclusion: Angiographic findings reveal the complex relationship between the dominance of the VA, patterns of stenosis, and demographic factors. Individuals with a dominant VA had a greater likelihood of developing stenosis on the opposite non-dominant side. The high occurrence of severe stenosis highlights the need for tailored diagnostic and treatment approaches. Understanding vertebral stenosis as a multifaceted interaction of demographic, lifestyle, and anatomical variables is essential for enhancing treatment strategies.

1 March 2023 in Journal of Medicine and Life
Verified
Journal Article
Open access
MAmohammad Ayasrah
mohammad Ayasrah
IQIzzeddin Qtaish
Izzeddin Qtaish
Magnetic resonance imaging (MRI) is essential for assessing shoulder conditions. This study aimed to evaluate current shoulder MRI practices in Jordan, including technical parameter patterns, and determine if they adhere to the American College of Radiology (ACR) guidelines. The retrospective analysis included data from 48 eligible participants from 13 MRI centers in March 2021. Descriptive and correlation data analysis were performed using IBM SPSS statistics version_20 and Excel 2013. Most MRI centers (50%) were private outpatient clinics with closed MRI machines above 1 Tesla. Most participants (62.5%) were male, and shoulder pain (47.9%) was the main clinical indication. Most shoulder orientations (68.7%, 33/48) were right shoulders, and the coronal MRI planes (43%, 121/280) were the most common. The alignment percentage for the axial plane was 100%, but MRI artifacts of the shoulder were present in 8.2% of cases (23/280). Dark fluid T1-W coronal sequence was not conducted in 25% of the cases. The percentage of the field view (FOV) within ACR recommendations was 45% (126/281), and slice thickness parameters were 96% (269/281). The recommended pixel area for all sequences was 47.9% (134/280), encompassing all axial, sagittal oblique, and coronal planes. However, crucial parameters, such as FOV and slice thickness, were inadequate and did not meet the ACR guidelines, resulting in suboptimal image quality of shoulder MRI. To improve MRI image quality, it is recommended that MRI technologists receive ongoing education and training on appropriate MRI image parameters.

1 May 2022 in Medical Devices: Evidence and Research
Verified
Journal Article
Open access
PDF file
MAmohammad Ayasrah
mohammad Ayasrah
Purpose: The absence of ionizing radiation in MRI applications does not guarantee absolute safety. Implementing of safety guidelines can ensure high-quality practice in the clinical MRI with the minimum risk. For this purpose, this cross-section quantitative study conducted in Jordan Kingdom aimed to assess current MRI safety guidelines in comparison with those of 2020 Manual on MR Safety of the American College of Radiology (ACR). Patients and Methods: A site observation study of 38 MRI units was undertaken in June 2021. A well-structured MRI safety questionnaire was the primary data collection method. Data were subjected to a descriptive statistics content analysis by the SPSS version 20. The results were analyzed to yield comprehensive discussions. Results: A total of 38 MRI facilities in participated in this study with the responding rate of 44.7%. Patient screening areas and changing rooms were available in about 29% (11/38) of the MRI facilities. Most facilities (55%, 21/38) conducted verbal screening only whereas 21% implemented both written and verbal screening for their patients and companions in zone II, which was present in a percentage of 29% in the approached facilities. Meanwhile, only 13 (43.2%) of 38 facilities used handheld magnets for physical screening, 25 (65.8%) of MRI units did not use any kind of ferromagnetic metal detection systems. Three (7.9%) participating centers had MR-safe wheelchairs, ventilators, anesthesia machines, and stretchers. Most MRI facilities participating in this study (71%) had emergency preparedness plans for alternative power outages. Despite a relatively low number of participating centers having an emergency exit or code (26.3% and 10.5%, respectively), none of them performed practice drills for such scenarios. Conclusion: Investing in new MR-safe equipment requires introducing ferromagnetic detecting systems. More research is needed to establish the degree of MRI professional’s safety-related education.

30 November 2023 in Current Medical Imaging
Verified
Journal Article
Open access
PDF file
IQIzzeddin Qtaish
Izzeddin Qtaish
MAmohammad Ayasrah
mohammad Ayasrah
NQNoat R. Qtaish
Noat R. Qtaish
Background:: Hepatic artery aneurysms (HAAs) exhibit a notable risk of rupture, with both true aneurysms and pseudoaneurysms being exceptionally uncommon (incidence rate approximately 2 per 100,000). Symptoms include epigastric and right upper quadrant pain, jaundice, and potentially life-threatening bleeding upon rupture. This bleeding can extend into the portal vein, hepatic vein, biliary system, or abdominal cavity. While existing literature lacks reports of delayed post-therapeutic complications, this case report discusses a 27-year-old female who developed a pseudoaneurysm six months after bilateral biliary drain insertion, underscoring the potential for delayed complications. Case Presentation:: The patient underwent gastric endoscopy revealing an extensive lower esophageal varix protruding into the proximal stomach, subsequently treated with banding. The stomach and duodenum were found to contain fresh blood and blood clots indicating acute bleeding. : An urgent CT scan identified active bleeding (extravasation) at segment V and blood accumulation at the confluence of the right and left biliary drains. This was followed by celiac and selective hepatic digital subtraction angiography (DSA). Conclusion:: This case study outlines the occurrence of a hepatic artery pseudoaneurysm six months after percutaneous insertion of bilateral biliary drains. The pseudoaneurysm manifested precisely at the confluence of the right and left drains. The reported delayed complication may have resulted from friction between the drains at the confluence or erosion of the adjacent artery by the drains. The insights gained from this case shed light on the causes and preventive measures for potential delayed complications associated with percutaneous biliary drain placement.

1 January 2025 in Cancer Management and Research
Verified
Journal Article
Open access
PDF file
RHRasha Al Hrout
Rasha Al Hrout
MAmohammad Ayasrah
mohammad Ayasrah
NANurul Zahirah Noor Azman
Nurul Zahirah Noor Azman
Introduction: Breast cancer is a significant worldwide health issue, particularly in Jordan, where early detection via mammography is essential for effective disease management. Despite the little radiation risk associated with mammography, it is crucial to monitor radiation exposure to guarantee patient safety. This study intends to assess skin entrance exposure and compute the Mean Glandular Dose (MGD) in mammography units to determine adherence to established criteria and pinpoint areas for enhancement. Methods: To assess MGD, the study utilized the American College of Radiologists (ACR) phantom alongside a RaySafe X2 MAM dosimeter. Measurements of entrance kerma and half-value layer (HVL) were taken across 25 mammography units in Jordan. The MGD was calculated according to the ACR’s 2018 protocol, which provides a standardized approach to ensure accurate and comparable dose estimations. These measurements were then analyzed against the ACR’s threshold of 3 mGy to assess compliance. Results: The study found that the average MGD across all units was 2.3 mGy, with individual values ranging from 0.95 to 4.10 mGy. Although 67% of the units maintained MGD values within the ACR threshold, 33% exceeded the recommended limit of 3 mGy. Higher MGD values were particularly common in non-accredited facilities, where the average MGD reached 2.7 mGy, compared to 1.6 mGy in accredited units, suggesting gaps in quality control and adherence to best practices in non-accredited centers. Conclusion: This study emphasizes the critical role of accreditation and adherence to quality standards in maintaining safe and effective mammography practices. While most mammography units in Jordan meet the ACR’s recommended MGD limits, the elevated dose levels in some non-accredited facilities highlight the need for more rigorous implementation of accreditation standards. Improving compliance with established guidelines will enhance breast cancer screening effectiveness, ultimately supporting better early detection and outcomes for breast cancer in Jordan.

1 May 2026 in Journal of Healthcare Leadership
Verified
Journal Article
Open access
MAmohammad Ayasrah
mohammad Ayasrah
YAYoussef Alrashdan
Youssef Alrashdan
Communicating radiation dose to nurses using Sievert-based units may be difficult to interpret and may heighten anxiety. Chest Equivalent Dose (CED) is a symbolic approach that anchors dose information to a familiar chest imaging reference frame. To compare the effects of Chest Equivalent Dose (CED) versus conventional Sievert-based dose communication on nurses’ radiation knowledge, radiation anxiety, and radiation-related feelings/experiences. A quasi-experimental pretest–posttest comparative study was conducted among nurses in Jordan. Participants received Sievert-based education (n=40) or CED-based education (n=31). Radiation knowledge (RKQ), radiation anxiety (RAQ), and radiation-related feelings and experiences (RREF) were measured immediately before and after the session. Paired- and independent-samples tests were used, and time effects were explored using mixed-model analyses. Baseline scores did not differ between groups (all p>0.05). In the CED group, RKQ increased from 59.76±8.32 to 79.76±10.16, while RAQ decreased from 57.97±1.33 to 36.74±1.83 and RREF decreased from 77.58±2.87 to 47.12±2.90 (all p<0.001). In the Sievert group, RKQ was unchanged (56.08±10.89 to 58.32±9.04; p=0.329), with small decreases in RAQ (58.23±1.19 to 56.45±1.58; p<0.001) and RREF (77.67±3.02 to 75.67±3.17; p=0.005). Posttest outcomes favoured CED for RKQ, RAQ, and RREF (all p<0.001). CED-based symbolic dose communication produced larger improvements in knowledge and larger reductions in anxiety and radiation-related experiences than Sievert-based education.