Shuai Guo

Dr. Shuai Guo

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2017 in Journal of Hydraulic Engineering
Verified
Journal Article
Closed access
SGShuai Guo
Shuai Guo
DZDavid Zhiwei Zhu
David Zhiwei Zhu
As sewer pipes age, groundwater and the surrounding soil can enter into the sewer system through various defects on the pipe wall. Groundwater infiltration and soil erosion through cracked sewer pipes can result in increased sewage loading and cause sinkhole problems. A reliable model is needed to assess the soil and water erosion rates. By incorporating the related resistances during the erosion process, this paper presents improved expressions for calculating soil and groundwater erosion rates through the crack into a sewer pipe. Good agreement between experimental and predicted results on soil erosion rate is obtained. The analytical models indicate that the soil and water erosion rates are mainly controlled by the following factors: groundwater table or saturated soil height above the crack, particle size, particle shape, submerged repose angle, void ratio, and defect size.

1 March 2018 in Journal of Environmental Engineering
Verified
Journal Article
Closed access
SGShuai Guo
Shuai Guo
YQYu Qian
Yu Qian
DZDavid Zhiwei Zhu
David Zhiwei Zhu
WZWenming Zhang
Wenming Zhang
SEStephen Edwini-Bonsu
Stephen Edwini-Bonsu
Understanding hydrogen sulfide (H2S ) emission into sewer air space and the rate of ventilation to the atmosphere is important in preventing/mitigating odor and corrosion problems in sewer systems. This study presents the results of a field monitoring program on the air pressure and H2S levels in a 3-km-long sanitary sewer system in Edmonton, Alberta, Canada, which has drop structures in the upstream section and a pump station in the downstream section. Nineteen manholes were monitored, including six drop structures. A positive correlation was found between the sewage flow rate and the observed diurnal patterns of air pressure and H2S concentration. Drop structures were found to have caused significant pressurization in the downstream sewer air space. More than 1 km of the trunk sewer upstream of the pump station was submerged due to the pump station operation. This reduces flow velocity, increases sewage retention time, and potentially enhances the generation of H2S . A unique pressure pattern was found at several locations upstream of the pump station, which was closely related to the sewage level variation in the wet-well as a result of pump operations. The results reveal the ventilation condition in the study sewer system and will be useful for developing sewer odor mitigation measures.

15 March 2020 in Water Science & Technology
Verified
Journal Article
Open access
PDF file
GPGang Pan
Gang Pan
BWBao Wang
Bao Wang
SGShuai Guo
Shuai Guo
WZWenming Zhang
Wenming Zhang
SEStephen Edwini-Bonsu
Stephen Edwini-Bonsu
The City of Edmonton has been suffering from sewer odour problem for many years. Ten years of odour complaints data from 2008 to 2017 were statistically analyzed to identify major factors that relate to the odour problem. Spatial and temporal distributions of odour complaints in the city were first presented. Then relationships between the complaints and physical attributes of the sewer systems were analyzed by introducing a parameter of risk index. It was found that the snowmelt and storm events could possibly reduce odour complaints. Old sewer pipes and large drop structures are statistically more linked and thus significantly contribute to the complaints. The risk index relationship for three pipe materials is clay pipe > concrete pipe > PVC pipe. Combined sewers are more problematic in terms of odour complaints than sanitary sewers. And no clear correlation has been found between the changes of sewer pipe slope or angle and the complaints.

29 October 2020 in Water Science & Technology
Verified
Journal Article
Open access
PDF file
SGShuai Guo
Shuai Guo
XSXiang Shi
Xiang Shi
XLXujia Luo
Xujia Luo
HYHaoming Yang
Haoming Yang
Previous studies on the extraneous water problem (or infiltration/inflow) in sanitary sewer systems assumed that the wastewater flow is mainly composed of foul sewage (FS), groundwater infiltration (GWI) and rainfall-derived inflow and infiltration (RDII). Most existing assessment methods are based on this assumption. In 2018, China initiated the ‘Protection of the Yangtze River Program’, and the two-year research data showed that it was neither the GWI nor the RDII but the direct surface water intrusion (DSWI), which has rarely been reported in literatures, that serves as the main source of the extraneous water in many local sewer systems. The discovery has enriched the understanding of the extraneous water in sewer systems. Meanwhile, it brings new challenges for the assessment of extraneous water. In this study, starting from the analysis of the low influent concentration of chemical oxygen demand (COD) of the wastewater treatment plant in a southeastern city in China, a river water intrusion point was successfully localized and the volume of river water intrusion was quantified by a series of field experiments. The methodology used in this study can also be applied in other areas with DSWI.

14 August 2017 in Water Supply
Verified
Journal Article
Closed access
PDF file
YTYao Tang
Yao Tang
DCDave H. Chan
Dave H. Chan
DZDavid Z. Zhu
David Z. Zhu
SGShuai Guo
Shuai Guo
An analytical solution was proposed for the groundwater flow through a defective pipe, which can be used to estimate the water flow rate into the pipe and predict the pore water pressure distribution in surrounding soils. This analytical solution was verified by comparing with experimental results, and the predicted pressure distribution around the defective pipe is proved to be consistent with numerical simulations using the finite element method. From the parametric analysis, the infiltration rate increases as the defect position changes from top to bottom on the pipe, and the effect of defect position is not significant if the water head above the defect is 10 times greater than pipe radius. An approximated solution for estimating the groundwater flow infiltration rate through a circular orifice on the pipe is proposed as well. From the verification and parametric studies, this proposed analytical solution is proved to be an efficient approach for the estimation of groundwater infiltration through a defective pipe.

20 December 2021 in Water Science & Technology
Verified
Journal Article
Open access
PDF file
SGShuai Guo
Shuai Guo
RDRui Ding
Rui Ding
BHBiao Huang
Biao Huang
DZDavid Z. Zhu
David Z. Zhu
WZWenming Zhou
Wenming Zhou
MLMei Li
Mei Li
In recent years, three simple tracers (conductivity, turbidity and temperature) have shown their advantages to many other tracers for tracing and assessment of extraneous water (or inflow and infiltration, I/I) into sewer systems due to low detection cost and high monitoring frequency. A better understanding of the error and uncertainty of the three simple tracers on the quantification of I/I will help to improve the reliability and reduce the cost of actual projects. A large-scale experimental model simulating a 36 m long sewer was constructed for conducting extraneous water flow tests including groundwater infiltration, wastewater inflow and hot water inflow under different I/I flow rates and concentrations. The accuracy and uncertainty of the three tracers were estimated, and their correlation with tracer concentration difference before and after extraneous inflow was also analyzed. Experimental results provide guidance for the practical applicability of the three tracers under different I/I conditions.