Recent advancements have tangibly changed the cancer treatment landscape. However, curative therapy for this dreadful disease remains an unmet need. Sonodynamic therapy (SDT) is a minimally invasive anti-cancer therapy involving a chemical sonosensitizer and focused ultrasound. A high-intensity focused ultrasound (HIFU) beam is used to destroy or denature targeted cancer tissues. Some SDTs are based on unfocused ultrasound (US). In some SDTs, HIFU is combined with a drug, known as a chemical sonosensitizer, to amplify the drug’s ability to damage cancer cells preferentially. The mechanism by which US interferes with cancer cell function is further amplified by applying acoustic sensitizers. Combining multiple chemical sonosensitizers with US creates a substantial synergistic effect that could effectively disrupt tumorigenic growth, induce cell death, and elicit an immune response. Therefore, the minimally invasive SDT treatment is currently attracting attention. It can be combined with targeted therapy (double-targeting cancer therapy) and immunotherapy in the future and is expected to be a boon for treating previously incurable cancers. In this paper, we will consider the current state of this therapy and discuss parts of our research.
In order to prevent retainment of surgical instruments, number and kind of the instruments have to be counted correctly before and after operation. We propose a management system of surgical instruments by using radio frequency identification (RFID) technology. One of the features of the system is multi-tag reading and robustness against adhesion of blood. We have developed a RFID tag that is applicable in the sterilization process and a RFID reader/writer. The present study examines usability of the application software to support the surgical instruments assembly at the central supply section. Evaluation tests were conducted by the medical staff at hospital using the proposed system. As a result, setting time by using the RFID system was found to increase by 13.7%, in comparison to the conventional manual assembly. Considering that the conventional method needs two medical professionals for double-check, the system, which enables double-check with only one professional, could reduce total assembly time almost to half. Furthermore, the system successfully detected a miscount which happened in one subject and gave alert. Through the clinical evaluations, it is suggested that the proposed system could improve the safety and reliability of tray assembly.