Zone 0 landing hybrid thoracic endovascular aortic repair (TEVAR) includes a few moderately invasive surgical procedures. To reduce invasiveness, TEVAR with a branched aortic arch stent-graft can be considered. This study aimed to elucidate the effectiveness of performing TEVAR using a Bolton (Bolton Medical, Inc, Sunrise, Fla) branched endograft by analyzing early and midterm results. We enrolled 28 patients (mean age, 78.4 years) who underwent TEVAR with the Bolton branched endograft in Osaka University Hospital between October 2012 and June 2018 with a mean follow-up period of 4.0 years. Double-side and single-side branched devices were used in 24 (85.7%) and 4 (14.3%) patients, respectively. All procedures were successful; no cases of endoleak or conversion to open repair were noted during the 30-day postoperative period. The perioperative stroke rate was 14.3% (4 out of 28); midterm stroke was not detected. All patients with perioperative stroke had atheroma grade ≥2 in the brachiocephalic artery. No type 1a endoleak was reported during the early or midterm results. The cumulative survival rate, aorta-related death-free rate, and aortic event-free survival rate at 5 years were 80.8%, 95.8%, and 81.6%, respectively. We achieved satisfactory early and midterm results by using a Bolton branched endograft for high-risk patients with arch pathologies except for high postoperative stroke. Although this treatment method is associated with postoperative stroke, performing strict evaluation of atheroma may prevent such complication. By preventing intraoperative stroke, TEVAR with this custom-made Bolton branched endograft may be considered a less-invasive treatment.
Purpose: To identify the optimal proximal landing zone for thoracic aortic endovascular repair (TEVAR) of aortic arch pathologies so as to avoid the bird-beak phenomenon that leads to type Ia endoleak. Materials and Methods: A retrospective single-center review was conducted of 164 patients (mean age 70.3±10.8 years, range 29–93; 127 men) who underwent repairs of the aortic arch using hybrid TEVAR from April 2008 to March 2017. The patients were divided into 2 groups according to the proximal landing zone: 43 zone 0 patients (26.2%) had total debranching TEVAR (n=18) or total endovascular aortic repair (n=25) while 121 patients (73.8%) had TEVAR landing in zones 1 (n=41) or 2 (n=80). Bird-beak configurations, endoleaks, and stent migrations were assessed on the postoperative and latest computed tomography angiography (CTA) scans. Overall survival and freedom from the bird-beak configuration, aorta-related death, and aortic events were estimated using the Kaplan-Meier method. Hazard ratios (HR) were calculated with the 95% confidence interval (CI). Results: All procedures were successful, without any 30-day mortality. There were 3 early complications (1.8%; all strokes) and 10 early endoleaks (6.1%; no type Ia). On the first postoperative CTA, 42 patients (25.6%) had a bird-beak configuration. The zone 0 patients had significantly fewer (p<0.001), shorter (p<0.004), and less angulated (p3-mm progression. The freedom from bird-beak configuration estimate was significantly higher in the zone 0 group (95.4%) vs zones 1–2 (57.8%; HR 0.10, 95% CI 0.02 to 0.31, p<0.001). There were 9 late endoleaks (4 type Ia; none in the zone 0 group). The rate of stent-graft migration was significantly lower in the zone 0 group (2.3% vs 14.1% in zones 1–2, p=0.035). Conclusion: Early and most late results in zone 0 TEVAR were equal to those in zones 1 and 2; however, there were no late type Ia endoleaks and fewer bird-beak configurations associated with zone 0 TEVAR, which suggests that zone 0 landing is advantageous for preventing these complications.
13 February 2021 in European Journal of Cardio-Thoracic Surgery
: OBJECTIVES: Thoracic endovascular aortic repair (TEVAR) has been gradually extended to the aortic arch region, with improved results. However, the rates of strokes and endoleaks in a hybrid TEVAR remain high. The goal of this study was to clarify the effectiveness of a hybrid TEVAR with a zone 0 landing using our treatment strategy. METHODS: From April 2008 to March 2020, a total of 102 patients were enrolled in this study, with a median follow-up period of 3.2 years. The procedures included total debranching TEVAR with graft replacement of the ascending aorta in 62 patients, total debranching TEVAR with ascending aorta banding in 19 patients and total debranching TEVAR without ascending aorta banding in 21 patients. RESULTS: Thirty-day mortality and hospital deaths were 1.0% (n = 1) and 3.9% (n = 4), respectively. The rates of aortic complications and endoleaks during the first 30 days postoperatively were 8.8% (n = 9) and 4.9% (n = 5), respectively. There was no type 1a endoleak, whereas retrograde type A dissection occurred in 2 (2.0%) patients. The rate of late aortic events was 3.9% (n = 4); there were no late endoleaks or aneurysm ruptures. The 10-year survival rate was 73.7% [95% confidence interval (CI) 60.3–83.8%]. The 10-year rates of aorta-related deaths and aortic events when performing a competitive-risk analysis were 29.4% (95% CI 16.3–42.5%) and 7.2 (95% CI 23.0–51.4%), respectively. CONCLUSIONS: Satisfactory early and long-term results of a hybrid TEVAR with a zone 0 landing were achieved using our treatment strategy. When performing hybrid TEVAR in zone 0, postoperative aortic events may be reduced by accurate preoperative assessment of the ascending aorta.
1 March 2022 in European Journal of Vascular and Endovascular Surgery
Purpose: Zone 0 landing in thoracic endovascular aortic repair (TEVAR) has recently gained increasing attention for the treatment of high-risk patients. The aim of this study was to compare the outcomes of total endovascular aortic arch repair between branched TEVAR (bTEVAR) and chimney TEVAR (cTEVAR) in the landing zone (LZ) 0. Materials and Methods: This was a single-center, retrospective, and observational cohort study. From January 2010 to March 2020, 40 patients (bTEVAR, n=25; cTEVAR, n=15; median age: 79 years) were enrolled in this study, with a median follow-up period of 4.1 years. These patients were considered unsuitable for open surgical treatment. Results: All procedures were successful and no cases of conversion to open repair were noted during the 30-day postoperative period. The 30-day mortality was 2.5% (n=1; bTEVAR [0 of 25, 0%] vs cTEVAR [1 of 15, 6.7%]; p=0.375), the perioperative stroke rate was 10.0% (n=4; bTEVAR [4 of 25, 16.0%] vs cTEVAR [0 of 15, 0%], p=0.278), and type 1a endoleak rate was 15.0% (n=6; bTEVAR [0 of 25, 0%] vs cTEVAR [6 of 15, 40.0%], p=0.001). The risk factor for stroke was atheroma grade of ≥2 in the brachiocephalic artery (p<0.001). The risk factor for type 1a endoleak was cTEVAR (p=0.001). The 8-year survival rate was 49.9%. The aorta-related death-free rate and aortic event-free rate at 8 years were 94.4% (bTEVAR: 95.5% vs cTEVAR: 93.3%, p=0.504) and 60.7% (bTEVAR: 70.7% vs cTEVAR: 40.0%, p=0.048), respectively. Conclusions: Total endovascular aortic arch repair using bTEVAR and cTEVAR is feasible for the treatment of aortic arch diseases in high-risk patients who are unsuitable for open surgery. However, as the rate of stroke is high, strict preoperative evaluation to prevent stroke is needed. No rupture of the aneurysm was observed in cTEVAR, but patients should be selected carefully because of the high incidence of type 1a endoleak.
8 November 2024 in General Thoracic and Cardiovascular Surgery Cases
Background: Ascending aortic thrombus is a rare disease that can cause fatal thromboembolism. The treatment for the disease is not well defined and depends on the clinical experience of surgeons. Most reports of thrombosis in antiphospholipid syndrome (APS) are associated with venous or peripheral arterial thrombosis, and there are almost no reports of thrombosis of the aorta. Case presentation: A 74-year-old male was referred to our department with claudication of the left leg lasting 3 months. A computed tomography angiography (CTA) and a transthoracic echocardiography demonstrated that a floating and pedunculated mass associated with APS was located at ascending aortic lumen and an embolism in the left superficial femoral artery. Under deep hypothermic circulatory arrest, we resected a floating mass without the graft replacement. CTA 1 year after surgery showed no recurrence of thrombus. Conclusion: We experienced a rare case of floating ascending aortic thrombi. As in this case, we consider that a floating ascending aortic thrombus with embolic events should be performed by surgical intervention.