Dessalegn Bitew Aeggegn

Dessalegn Bitew Aeggegn


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2024 in Results in Engineering
Verified
Journal Article
Open access
DADessalegn Bitew Aeggegn
Dessalegn Bitew Aeggegn
GNGeorge Nyauma Nyakoe
George Nyauma Nyakoe
CWCyrus Wekesa
Cyrus Wekesa


1 January 2024 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
DADessalegn Bitew Aeggegn
Dessalegn Bitew Aeggegn
GNGeorge Nyauma Nyakoe
George Nyauma Nyakoe
CWCyrus Wekesa
Cyrus Wekesa
DC‐DC converters are essential for integrating distributed energy resources into microgrid (MG) systems. These converters are designed to incorporate intermittent renewable energy sources such as solar photovoltaic (PV) panels, fuel cells (FCs), and battery energy storage systems (BESSs) into the grid. However, conventional DC‐DC converters have limitations including lower efficiency, voltage ripple, insufficient voltage regulation, and compatibility issues. This article presents boost and bidirectional buck‐boost converters for direct current microgrid (DCMG) applications, employing an adaptive neuro‐fuzzy inference system (ANFIS) for control. These proposed converter configurations adeptly manage wide input voltage fluctuations from intermittent sources, consistently supplying power to the DC bus at 500 V and 120 V for boost and buck operations, respectively, with an efficiency of 98.8%. The output voltage result shows that the ANFIS‐based boost converter has 10% overshoot as compared to 41% and 50% overshoot in proportional integral (PI) and fuzzy logic controller (FLC), respectively. In both buck and boost modes, the converters’ voltage gain is influenced by duty ratio adjustments only, not sensitive to dynamic input voltage and flexible manipulation of the output voltage for BESS charging. Moreover, the designed converters accommodate load variations within the MG. To assess the converters’ ability to regulate output voltage effectively, PI, FLC, and ANFIS controllers are implemented and compared. And the ANFIS controller demonstrates superior performance, offering faster response times and enhanced stability. Evaluations are conducted through simulations in the MATLAB/Simulink environment.

13 April 2024 in Cogent Engineering
Verified
Journal Article
Open access
DADessalegn Bitew Aeggegn
Dessalegn Bitew Aeggegn
GNGeorge Nyauma Nyakoe
George Nyauma Nyakoe
CWCyrus Wekesa
Cyrus Wekesa

7 May 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
DBDerradji Bakria
Derradji Bakria
ALAbdelkader Azzeddine Laouid
Abdelkader Azzeddine Laouid
BKBelkacem Korich
Belkacem Korich
ABAbdelkader Beladel
Abdelkader Beladel
ATAli Teta
Ali Teta
SGSherif S. M. Ghoneim
Sherif S. M. Ghoneim
Integration of nonlinear loads in modern power systems has led to many issues arising mainly due to the generation of harmonic currents and the presence of reactive power, both having adverse effects on power quality and grid stability. Harmonic currents cause increased losses, overheating of equipment, and voltage distortions, while reactive power imbalances result in inefficiencies in power delivery and compromised system performance. To overcome these problems, a Shunt Active Power FIlter design and an optimal control strategy for harmonic mitigation and reactive power compensation are proposed in this paper. The design incorporates an optimized anti-windup PI controller for DC-link voltage regulation and an optimized output filter to enhance the quality of the injected current. This design is formulated as an optimization problem and solved using the Golden Jackal Optimizer. MATLAB/Simulink simulations validate the proposed method under different operating conditions, covering dynamic change of loads and unbalanced grid conditions. The result shows a remarkable reduction in Total Harmonic Distortion (THD) of grid current, and reactive power compensation meanwhile maintaining the stability of the grid.

4 March 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
FMFaycal Medjili
Faycal Medjili
ABAbderrahmen Bouguerra
Abderrahmen Bouguerra
MLMohamed Ladjal
Mohamed Ladjal
BBBadreddine Babes
Badreddine Babes
EAEnas Ali
Enas Ali
ASAhmed B. Abou Sharaf
Ahmed B. Abou Sharaf
Accurate regulation of the liquid level in a quadruple tank system (QTS) is not easy and imposes higher requirements on control strategies, so the design of controllers in these systems is challenging due to the difficulty of dynamic analysis of its nonlinear characteristics and parametric uncertainties. To overcome these problems in liquid level regulation and increase the robustness to the pump coefficients, this article proposes and investigates the use of an optimal hybrid fractional-order type-2 fuzzy-PID (OH-FO-T2F-PID) regulator using a combination of two bio-inspired evolutionary optimizers, namely augmented grey wolf optimizer and cuckoo search optimizer, which gives rise to the new hybrid A-GWOCS algorithm. This control mechanism was chosen to facilitate the convergence of the water liquids in the two tanks as quickly as possible to the corresponding required values. In addition, a collaborative optimization technique with several objectives is used to adjust the regulator parameters. The capability and efficiency of the suggested regulator is first investigated through computer simulation results and then confirmed by real-time control experimental results on the QTS based on dSPACE 1104 computation engine. The findings showed that the suggested OH-FO-T2F-PID regulator significantly outperformed both the optimized ADRC and the OH-FO-T1F-PID regulators. Specifically, it reduced the rising time by 17.02% and 95.21%, respectively, and the settling time by 25.13% and 74.28%. Additionally, the designed OH-FO-T2F-PID regulator successfully eliminated the steady-state error and overshoot, enabling precise regulation of the QTS, and maintenance the liquid level at the desired set point under a wide range of working situations. The robustness of the recommended regulator is also studied by considering − 50% disturbance in the QTS parameters, and the findings showed that the OH-FO-T2F-PID regulator is less susceptible to variations in parameters.