Thomas Breuer

Dr. Thomas Breuer

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2017 in Diabetes Care
Verified
Journal Article
Open access
PDF file
LMLena Mumme
Lena Mumme
TBThomas Breuer
Thomas Breuer
SRStephan Rohrer
Stephan Rohrer
NSNina Schenker
Nina Schenker
BMBjörn A. Menge
Björn A. Menge
JMJuris J. Meier
Juris J. Meier
OBJECTIVE: Diabetes frequently develops in patients with chronic pancreatitis. We examined the alterations in the glucagon response to hypoglycemia and to oral glucose administration in patients with diabetes due to chronic pancreatitis. RESEARCH DESIGN AND METHODS: Ten patients with diabetes secondary to chronic pancreatitis were compared with 13 patients with type 2 diabetes and 10 healthy control subjects. A stepwise hypoglycemic clamp and an oral glucose tolerance test (OGTT) were performed. RESULTS: Glucose levels during the OGTT were higher in patients with diabetes and chronic pancreatitis and lower in control subjects (P < 0.0001). Insulin and C-peptide levels were reduced, and the glucose-induced suppression of glucagon was impaired in both groups with diabetes (all P < 0.0001 vs. control subjects). During hypoglycemia, glucagon concentrations were reduced in patients with chronic pancreatitis and with type 2 diabetes (P < 0.05). The increase in glucagon during the clamp was inversely related to the glucose-induced glucagon suppression and positively related to β-cell function. Growth hormone responses to hypoglycemia were lower in patients with type 2 diabetes (P = 0.0002) but not in patients with chronic pancreatitis. CONCLUSIONS: α-Cell responses to oral glucose ingestion and to hypoglycemia are disturbed in patients with diabetes and chronic pancreatitis and in patients with type 2 diabetes. The similarities between these defects suggest a common etiology.

17 February 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
Christian BleilevensChristian Bleilevens
Christian Bleilevens
JSJosefin Soppert
Josefin Soppert
AHAdrian Hoffmann
Adrian Hoffmann
TBThomas Breuer
Thomas Breuer
JBJürgen Bernhagen
Jürgen Bernhagen
TSTim Philipp Simon
Tim Philipp Simon
Mortality in critically ill coronavirus disease 2019 (COVID-19) patients is high and pharmacological treatment strategies remain limited. Early-stage predictive biomarkers are needed to identify patients with a high risk of severe clinical courses and to stratify treatment strategies. Macrophage migration inhibitory factor (MIF) was previously described as a potential predictor for the outcome of critically ill patients and for acute respiratory distress syndrome (ARDS), a hallmark of severe COVID-19 disease. This prospective observational study evaluates the predictive potential of MIF for the clinical outcome after severe COVID-19 infection. Plasma MIF concentrations were measured in 36 mechanically ventilated COVID-19 patients over three days after intensive care unit (ICU) admission. Increased compared to decreased MIF was significantly associated with aggravated organ function and a significantly lower 28-day survival (sequential organ failure assessment (SOFA) score; 8.2 ± 4.5 to 14.3 ± 3, p = 0.009 vs. 8.9 ± 1.9 to 12 ± 2, p = 0.296; survival: 56% vs. 93%; p = 0.003). Arterial hypertension was the predominant comorbidity in 85% of patients with increasing MIF concentrations (vs. decreasing MIF: 39%; p = 0.015). Without reaching significance, more patients with decreasing MIF were able to improve their ARDS status (p = 0.142). The identified association between an early MIF response, aggravation of organ function and 28-day survival may open future perspectives for biomarker-based diagnostic approaches for ICU management of COVID-19 patients.

1 August 2019 in Nutrients
Verified
Journal Article
Open access
PDF file
Christian BleilevensChristian Bleilevens
Christian Bleilevens
BDbm doorschodt
bm doorschodt
TFTamara Fechter
Tamara Fechter
TGTim Grzanna
Tim Grzanna
ATAlexander Theißen
Alexander Theißen
GFGregor Fabry
Gregor Fabry
Systemic and localized ischemia and reperfusion injury remain clinically relevant issues after organ transplantation and contribute to organ dysfunctions, among which acute kidney injury is one of the most common. An in vitro test-circuit for normothermic perfusion of porcine kidneys after warm ischemia was used to investigate the antioxidant properties of vitamin C during reperfusion. Vitamin C is known to enhance microcirculation, reduce endothelial permeability, prevent apoptosis, and reduce inflammatory reactions. Based on current evidence about the pleiotropic effects of vitamin C, we hypothesize that the antioxidant properties of vitamin C might provide organ-protection and improve the kidney graft function in this model of ischemia and reperfusion. Methods: 10 porcine kidneys from 5 Landrace pigs were perfused in vitro for 6 h. For each experiment, both kidneys of one animal were perfused simultaneously with a 1:1 mixture of autologous blood and modified Ringer’s solution at 38 °C and 75 mmHg continuous perfusion pressure. One kidney was treated with a 500 mg bolus injection of vitamin C into the perfusate, followed by continuous infusion of 60 mg/h vitamin C. In the control test circuit, an equal volume of Ringer’s solution was administered as a placebo. Perfusate samples were withdrawn at distinct points in time during 6 h of perfusion for blood gas analyses as well as measurement of serum chemistry, oxidative stress and antioxidant capacity. Hemodynamic parameters and urine excretion were monitored continuously. Histological samples were analyzed to detect tubular- and glomerular-injury. Results: vitamin C administration to the perfusate significantly reduced oxidative stress (49.8 ± 16.2 vs. 118.6 ± 23.1 mV; p = 0.002) after 6 h perfusion, and increased the antioxidant capacity, leading to red blood cell protection and increased hemoglobin concentrations (5.1 ± 0.2 vs. 3.9 ± 0.6 g/dL; p = 0.02) in contrast to placebo treatment. Kidney function was not different between the groups (creatinine clearance vit C: 2.5 ± 2.1 vs. placebo: 0.5 ± 0.2 mL/min/100 g; p = 0.9). Hypernatremia (187.8 ± 4.7 vs. 176.4 ± 5.7 mmol/L; p = 0.03), and a lower, but not significant decreased fractional sodium excretion (7.9 ± 2 vs. 27.7 ± 15.3%; p = 0.2) were observed in the vitamin C group. Histological analysis did not show differences in tubular- and glomerular injury between the groups. Conclusion: Vitamin C treatment increased the antioxidant capacity of in vitro perfused kidney grafts, reduced oxidative stress, preserved red blood cells as oxygen carrier in the perfusate, but did not improve clinically relevant parameters like kidney function or attenuate kidney damage. Nevertheless, due to its antioxidative properties vitamin C might be a beneficial supplement to clinical kidney graft perfusion protocols.

6 January 2022 in Membranes
Verified
Journal Article
Open access
PDF file
PWPatrick Winnersbach
Patrick Winnersbach
AHAisa Hosseinnejad
Aisa Hosseinnejad
TBThomas Breuer
Thomas Breuer
TFTamara Fechter
Tamara Fechter
FJFelix Jakob
Felix Jakob
SSSmriti Singh
Smriti Singh
Background: Clot formation on foreign surfaces of extracorporeal membrane oxygenation systems is a frequent event. Herein, we show an approach that mimics the enzymatic process of endogenous nitric oxide (NO) release on the oxygenator membrane via a biomimetic, non-fouling microgel coating to spatiotemporally inhibit the platelet (PLT) activation and improve antithrombotic properties. This study aims to evaluate the potential of this biomimetic coating towards NO-mediated PLT inhibition and thereby the reduction of clot formation under flow conditions. Methods: Microgel-coated (NOrel) or bare (Control) poly(4-methyl pentene) (PMP) fibers were inserted into a test channel and exposed to a short-term continuous flow of human blood. The analysis included high-resolution PLT count, pooled PLT activation via β-Thromboglobulin (β-TG) and the visualization of remnants and clots on the fibers using scanning electron microscopy (SEM). Results: In the Control group, PLT count was significantly decreased, and β-TG concentration was significantly elevated in comparison to the NOrel group. Macroscopic and microscopic visualization showed dense layers of stable clots on the bare PMP fibers, in contrast to minimal deposition of fibrin networks on the coated fibers. Conclusion: Endogenously NO-releasing microgel coating inhibits the PLT activation and reduces the clot formation on PMP fibers under dynamic flow.

13 April 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TSTim Philipp Simon
Tim Philipp Simon
CSChristian Stoppe
Christian Stoppe
TBThomas Breuer
Thomas Breuer
LSLara Stiehler
Lara Stiehler
Michael DreherMichael Dreher
Michael Dreher
LMLukas Martin
Lukas Martin
The coronavirus disease 2019 (COVID-19) pandemic has placed a significant burden on hospitals worldwide. Objective biomarkers for early risk stratification and clinical management are still lacking. The aim of this work was to determine whether bioactive adrenomedullin can assist in the risk stratification and clinical management of critically ill COVID-19 patients. Fifty-three patients with confirmed COVID-19 were included in this prospective observational cohort study between March and April 2020. Bioactive adrenomedullin (bio-ADM) plasma concentration was measured daily for seven days after admission. The prognostic value and clinical significance of bio-ADM plasma levels were evaluated for the severity of respiratory failure, the need for extracorporeal organ support and outcome (28-day mortality). Bio-ADM levels increased with the severity of acute respiratory distress syndrome (ARDS; p < 0.001) and were significantly elevated in invasively ventilated patients (p = 0.006) and patients in need of extracorporeal membrane oxygenation (p = 0.040) or renal replacement therapy (RRT; p < 0.001) compared to patients without these conditions. Non-survivors showed significantly higher bio-ADM levels than survivors (p = 0.010). Bio-ADM levels predicted 28-day mortality (C-index 0.72, 95% confidence interval 0.56–0.87, p < 0.001). Bio-ADM plasma levels correlate with disease severity, the need for extracorporeal organ assistance, and outcome, and highlight the promising value of bio-ADM in the early risk stratification and management of patients with COVID-19.

1 December 2015 in Critical Care
Verified
Journal Article
Open access
PDF file
TBThomas Breuer
Thomas Breuer
CEChristoph Emontzpohl
Christoph Emontzpohl
MCMark Coburn
Mark Coburn
CBCarina Benstöm
Carina Benstöm
RRRolf Rossaint
Rolf Rossaint
CSChristian Stoppe
Christian Stoppe
Introduction: Cardiac surgery encompasses various stimuli that trigger pro-inflammatory mediators, reactive oxygen species and mobilization of leucocytes. The aim of this study was to evaluate the effect of xenon on the inflammatory response during cardiac surgery. Methods: This randomized trial enrolled 30 patients who underwent elective on-pump coronary-artery bypass grafting in balanced anaesthesia of either xenon or sevoflurane. For this secondary analysis, blood samples were drawn prior to the operation, intra-operatively and on the first post-operative day to measure the pro- and anti-inflammatory cytokines interleukin-6 (IL-6), interleukin-8/C-X-C motif ligand 8 (IL-8/CXCL8), and interleukin-10 (IL-10). Chemokines such as C-X-C motif ligand 12/ stromal cell-derived factor-1α (CXCL12/SDF-1α) and macrophage migration inhibitory factor (MIF) were measured to characterize xenon’s perioperative inflammatory profile and its impact on migration of peripheral blood mononuclear cells (PBMC). Results: Xenon enhanced the postoperative increase of IL-6 compared to sevoflurane (Xenon: 90.7 versus sevoflurane: 33.7 pg/ml; p = 0.035) and attenuated the increase of IL-10 (Xenon: 127.9 versus sevoflurane: 548.3 pg/ml; p = 0.028). Both groups demonstrated a comparable intraoperative increase of oxidative stress (intra-OP: p = 0.29; post-OP: p = 0.65). While both groups showed an intraoperative increase of the cardioprotective mediators MIF and CXCL12/SDF-1α, only MIF levels decreased in the xenon group on the first postoperative day (50.0 ng/ml compared to 23.3 ng/ml; p = 0.012), whereas it remained elevated after sevoflurane anaesthesia (58.3 ng/ml to 53.6 ng/ml). Effects of patients’ serum on chemotactic migration of peripheral mononuclear blood cells taken from healthy volunteers indicated a tendency towards enhanced migration after sevoflurane anaesthesia (p = 0.07). Conclusions: Compared to sevoflurane, balanced xenon anaesthesia triggers pro-inflammatory effects and suppresses the anti-inflammatory response in cardiac surgery patients even though the clinical significance remains unknown. Trial registration: This clinical trial was approved by the European Medicines Agency (EudraCT-number: 2010-023942-63) and at ClinicalTrials.gov (NCT01285271; first received: January 24, 2011).