Shiyu Chen Chen

Mr. Shiyu Chen Chen

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 August 2017 in Remote Sensing
Verified
Journal Article
Open access
PDF file
Yong ZhangYong Zhang
Yong Zhang
XYXiuxiao Yuan
Xiuxiao Yuan
WLWenzhuo Li
Wenzhuo Li
SCShiyu Chen Chen
Shiyu Chen Chen
Power line inspection ensures the safe operation of a power transmission grid. Using unmanned aerial vehicle (UAV) images of power line corridors is an effective way to carry out these vital inspections. In this paper, we propose an automatic inspection method for power lines using UAV images. This method, known as the power line automatic measurement method based on epipolar constraints (PLAMEC), acquires the spatial position of the power lines. Then, the semi patch matching based on epipolar constraints (SPMEC) dense matching method is applied to automatically extract dense point clouds within the power line corridor. Obstacles can then be automatically detected by calculating the spatial distance between a power line and the point cloud representing the ground. Experimental results show that the PLAMEC automatically measures power lines effectively with a measurement accuracy consistent with that of manual stereo measurements. The height root mean square (RMS) error of the point cloud was 0.233 m, and the RMS error of the power line was 0.205 m. In addition, we verified the detected obstacles in the field and measured the distance between the canopy and power line using a laser range finder. The results show that the difference of these two distances was within ±0.5 m.

Verified
Journal Article
Open access
PDF file
Yong ZhangYong Zhang
Yong Zhang
XYXiuxiao Yuan
Xiuxiao Yuan
YFYi Fang
Yi Fang
SCShiyu Chen Chen
Shiyu Chen Chen
When the distance between an obstacle and a power line is less than the discharge distance, a discharge arc can be generated, resulting in the interruption of power supplies. Therefore, regular safety inspections are necessary to ensure the safe operation of power grids. Tall vegetation and buildings are the key factors threatening the safe operation of extra high voltage transmission lines within a power line corridor. Manual or laser intensity direction and ranging (LiDAR) based inspections are time consuming and expensive. To make safety inspections more efficient and flexible, a low-altitude unmanned aerial vehicle (UAV) remote-sensing platform, equipped with an optical digital camera, was used to inspect power line corridors. We propose a semi-patch matching algorithm based on epipolar constraints, using both the correlation coefficient (CC) and the shape of its curve to extract three dimensional (3D) point clouds for a power line corridor. We use a stereo image pair from inter-strip to improve power line measurement accuracy by transforming the power line direction to an approximately perpendicular to epipolar line. The distance between the power lines and the 3D point cloud is taken as a criterion for locating obstacles within the power line corridor automatically. Experimental results show that our proposed method is a reliable, cost effective, and applicable way for practical power line inspection and can locate obstacles within the power line corridor with accuracy better than ±0.5 m.

FCFeiyan Chen
Feiyan Chen
LLLing Li
Ling Li
JNJiqiang Niu
Jiqiang Niu
ALAiwen Lin
Aiwen Lin
SCShiyu Chen Chen
Shiyu Chen Chen
HLHao Lin
Hao Lin
The concept of ecosystem services (ES) supply and demand has attracted increasing attention in science and policy making because it effectively links ecosystem services to human well-being. The imbalance of ES supply and demand in urban areas has become a key issue in regional sustainable development. In this context, we calculated ES supply and demand for Wuhan City, China, using the ES supply and demand ratio (ESDR) and the comprehensive ES supply–demand ratio (CESDR) to express the relationship between ES supply and demand. Ecological zoning was proposed according to the spatial differentiation of the ES supply–demand relationship, and policy recommendations are made. The results show that from the perspective of total ES supply and demand, the water yield supply (SWY), grain yield supply (SGY), and recreation services supply (SRS) are greater than the water yield demand (DWY), grain yield demand (DGY), and recreation services demand (DRS), and that the climate regulation supply (SCR) is less than the climate regulation demand (DCR). From a spatial perspective, there are imbalances and mismatches in ES supply and demand, especially in urban central areas. The values of SWY, SGY, SCS, and SRS per unit area are less than their respective demand values, and the area of mismatch has expanded with the gradual increase of the built-up area. The spatial pattern of ES supply and demand is circular, with the form of “deficit zone–relative equilibrium zone–surplus zone”, which corresponds to “urban central area–near suburbs–distant suburbs and rural areas”.

11 July 2018 in Remote Sensing
Verified
Journal Article
Open access
PDF file
SCShiyu Chen Chen
Shiyu Chen Chen
XYXiuxiao Yuan
Xiuxiao Yuan
Wei YuanWei Yuan
Wei Yuan
JNJiqiang Niu
Jiqiang Niu
FXFeng Xu
Feng Xu
Yong ZhangYong Zhang
Yong Zhang
Matching multi-sensor remote sensing images is still a challenging task due to textural changes and non-linear intensity differences. In this paper, a novel matching method is proposed for multi-sensor remote sensing images. To establish feature correspondences, an affinity tensor is used to integrate geometric and radiometric information. The matching process consists of three steps. First, features from an accelerated segment test are extracted from both source and target images, and two complete graphs are constructed with their nodes representing these features. Then, the geometric and radiometric similarities of the feature points are represented by the three-order affinity tensor, and the initial feature correspondences are established by tensor power iteration. Finally, a tensor-based mismatch detection process is conducted to purify the initial matched points. The robustness and capability of the proposed method are tested with a variety of remote sensing images such as Ziyuan-3 backward, Ziyuan-3 nadir, Gaofen-1, Gaofen-2, unmanned aerial vehicle platform, and Jilin-1. The experiments show that the average matching recall is greater than 0.5, which outperforms state-of-the-art multi-sensor image-matching algorithms such as SIFT, SURF, NG-SIFT, OR-SIFT and GOM-SIFT.

5 August 2016 in Preprints.org
Verified
Preprint
Open access
PDF file
Yong ZhangYong Zhang
Yong Zhang
XYXiuxiao Yuan
Xiuxiao Yuan
YFYi Fang
Yi Fang
SCShiyu Chen Chen
Shiyu Chen Chen
When the distance between an obstacle and a power line is less than the discharge distance, a discharge arc can be generated, resulting in interruption of power supplies. Therefore, regular safety inspections are necessary to ensure safe operations of power grids. Tall vegetation and buildings are the key factors threatening the safe operation of extra high voltage transmission lines within a power line corridor. Manual or LiDAR based-inspections are time consuming and expensive. To make safety inspections more efficient and flexible, a low-altitude unmanned aerial vehicle remote-sensing platform equipped with optical digital camera was used to inspect power line corridors. We propose a semi-patch matching algorithm based on epipolar constraints using both correlation coefficient and the shape of its curve to extract three dimensional (3D) point clouds for a power line corridor. Virtual photography was used to transform the power line direction from approximately parallel to the epipolar line to approximately perpendicular to epipolar line to improve power line measurement accuracy. The distance between the power lines and the 3D point cloud is taken as a criterion for locating obstacles within the power line corridor automatically. Experimental results show that our proposed method is a reliable, cost effective and applicable way for practical power line inspection, and can locate obstacles within the power line corridor with measurement accuracies better than ±0.5 m.