Aim: In recent years, the importance of fertility preservation (FP) has increased. In vitro maturation (IVM), an important technique in FP, has started to be used in the clinic, but controversies persist regarding this technique. Here, a survey of IVM for FP is provided.Methods: Based on a literature review, the applications of FP, methods of FP, IVM of oocytes that had been collected in vivo and ex vivo, maturation of oocytes after IVM for FP, cryopreservation of oocytes for FP, explanation of the procedures to patients, and recent research on FP using IVM were investigated.Results: Although IVM for FP remains controversial, the application of FP is expected to expand. Depending on the age and disease status of the patient, various methods of oocyte collection and ovarian stimulation, as well as various needle types and aspiration pressures, have been reported. The maturation rate of IVM in FP ranges widely and requires optimization in the future. In regard to cryopreservation for matured oocytes, the vitrification method is currently recommended.Conclusion: Regarding FP for patients with cancer, the treatment of cancer is prioritized; thus, the time and use of medicines are often constrained. As several key points regarding IVM remain unclear, well‐designed and specific counseling for patients is necessary.
28 April 2015 in Journal of Assisted Reproduction and Genetics
Recently, a new technique was developed for non-catalytically mixing microdroplets. In this method, an alternating-current (AC) electric field is used to promote the antigen–antibody reaction within the microdroplet. Previously, this technique has only been applied to histological examinations of flat structures, such as surgical specimens. In this study, we applied this technique for the first time to immunofluorescence staining of three-dimensional structures, specifically, mammalian eggs. We diluted an antibody against microtubules from 1:1,000 to 1:16,000 and compared the chromatic degree and extent of fading across dilutions. In addition, we varied the frequency of AC electric-field mixing from 5 Hz to 46 Hz and evaluated the effect on microtubule staining. Microtubules were more strongly stained after AC electric-field mixing for only 5 minutes, even when the concentration of primary antibody was 10 times lower than in conventional methods. AC electric-field mixing also alleviated microtubule fading. At all frequencies tested, AC electric-field mixing resulted in stronger microtubule staining than in controls. There was no clear difference in a microtubule staining between frequencies. These results suggest that the novel method could reduce antibody consumption and shorten immunofluorescence staining time.