The aim of this paper is to present and evaluate algorithms for heartbeat interval estimation from multiple spatially distributed force sensors integrated into a bed. Moreover, the benefit of using multichannel systems as opposed to a single sensor is investigated. While it might seem intuitive that multiple channels are superior to a single channel, the main challenge lies in finding suitable methods to actually leverage this potential. To this end, two algorithms for heart rate estimation from multichannel vibration signals are presented and compared against a single-channel sensing solution. The first method operates by analyzing the cepstrum computed from the average spectra of the individual channels, while the second method applies Bayesian fusion to three interval estimators, such as the autocorrelation, which are applied to each channel. This evaluation is based on 28 night-long sleep lab recordings during which an eight-channel polyvinylidene fluoride-based sensor array was used to acquire cardiac vibration signals. The recruited patients suffered from different sleep disorders of varying severity. From the sensor array data, a virtual single-channel signal was also derived for comparison by averaging the channels. The single-channel results achieved a beat-to-beat interval error of 2.2% with a coverage (i.e., percentage of the recording which could be analyzed) of 68.7%. In comparison, the best multichannel results attained a mean error and coverage of 1.0% and 81.0%, respectively. These results present statistically significant improvements of both metrics over the single-channel results (p <; 0.05).
1 January 2016 in European Clinical Respiratory Journal
Snoring (SN) is an early sign of upper airway dysfunction, and it is strongly associated with obstructive sleep apnea (OSA). SN detection is important to monitor SN objectively and to improve the diagnostic sensitivity of sleep-disordered breathing (SDB). In this study, an automatic snore detection method using an Emfit (Electromechanical film transducer) signal is presented. Representative polysomnographs of normal breathing (NB) and SN periods from 30 subjects were selected. Individual SN events were identified using source separation applying nonnegative matrix factorization deconvolution (NMFD). The algorithm was evaluated using manual annotation of the polysomnographic recordings. According to our results, the sensitivity (Se), and the positive predictive value (PPV) of the developed method to reveal snoring from the Emfit signal were 82.81% and 86.29%, respectively. Compared to other approaches, our method adapts to the individual spectral snoring profile of the subject rather than matching a particular spectral profile, estimates the snoring intensity, and obtains the specific spectral profile of the snores in the epoch. Additionally, no training is necessary. This study suggests that it is possible to detect individual SN events with Emfit mattress, which can be used as a contactless alternative to more conventional methods such as piezo-snore sensors or microphones.