Mirja Tenhunen

Dr. Mirja Tenhunen

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
CBChristoph Bruser
Christoph Bruser
JKJuha M. Kortelainen
Juha M. Kortelainen
SWStefan Winter
Stefan Winter
MTMirja Tenhunen
Mirja Tenhunen
JPJuha Parkka
Juha Parkka
Steffen LeonhardtSteffen Leonhardt
Steffen Leonhardt
The aim of this paper is to present and evaluate algorithms for heartbeat interval estimation from multiple spatially distributed force sensors integrated into a bed. Moreover, the benefit of using multichannel systems as opposed to a single sensor is investigated. While it might seem intuitive that multiple channels are superior to a single channel, the main challenge lies in finding suitable methods to actually leverage this potential. To this end, two algorithms for heart rate estimation from multichannel vibration signals are presented and compared against a single-channel sensing solution. The first method operates by analyzing the cepstrum computed from the average spectra of the individual channels, while the second method applies Bayesian fusion to three interval estimators, such as the autocorrelation, which are applied to each channel. This evaluation is based on 28 night-long sleep lab recordings during which an eight-channel polyvinylidene fluoride-based sensor array was used to acquire cardiac vibration signals. The recruited patients suffered from different sleep disorders of varying severity. From the sensor array data, a virtual single-channel signal was also derived for comparison by averaging the channels. The single-channel results achieved a beat-to-beat interval error of 2.2% with a coverage (i.e., percentage of the recording which could be analyzed) of 68.7%. In comparison, the best multichannel results attained a mean error and coverage of 1.0% and 81.0%, respectively. These results present statistically significant improvements of both metrics over the single-channel results (p <; 0.05).

1 January 2016 in European Clinical Respiratory Journal
Verified
Journal Article
Open access
PDF file
UAUlla Anttalainen
Ulla Anttalainen
MTMirja Tenhunen
Mirja Tenhunen
VRVille Rimpilä
Ville Rimpilä
OPOlli Polo
Olli Polo
EREsa Rauhala
Esa Rauhala
TSTarja Saaresranta
Tarja Saaresranta
Prolonged partial upper airway obstruction during sleep - an underdiagnosed phenotype of sleep-disordered breathing

1 June 2013 in Respiratory Physiology & Neurobiology
Verified
Journal Article
Closed access
MTMirja Tenhunen
Mirja Tenhunen
EEElla Elomaa
Ella Elomaa
HSHeli Sistonen
Heli Sistonen
EREsa Rauhala
Esa Rauhala
SHSari-Leena Himanen
Sari-Leena Himanen

20 October 2010 in Sleep and Breathing
Verified
Journal Article
Closed access
PDF file
MTMirja Tenhunen
Mirja Tenhunen
EREsa Rauhala
Esa Rauhala
JVJussi Virkkala
Jussi Virkkala
OPOlli Polo
Olli Polo
ASAntti Saastamoinen
Antti Saastamoinen
SHSari-Leena Himanen
Sari-Leena Himanen

1 November 2009 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
AKA. Kulkas
A. Kulkas
EHE. Huupponen
E. Huupponen
JVJ. Virkkala
J. Virkkala
MTMirja Tenhunen
Mirja Tenhunen
ASA. Saastamoinen
A. Saastamoinen
SHS.-L. Himanen
S.-L. Himanen

28 September 2017 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
JPJose Maria Perez-Macias
Jose Maria Perez-Macias
MTMirja Tenhunen
Mirja Tenhunen
Alpo VärriAlpo Värri
Alpo Värri
SHSari-Leena Himanen
Sari-Leena Himanen
JVJari Viik
Jari Viik
Snoring (SN) is an early sign of upper airway dysfunction, and it is strongly associated with obstructive sleep apnea (OSA). SN detection is important to monitor SN objectively and to improve the diagnostic sensitivity of sleep-disordered breathing (SDB). In this study, an automatic snore detection method using an Emfit (Electromechanical film transducer) signal is presented. Representative polysomnographs of normal breathing (NB) and SN periods from 30 subjects were selected. Individual SN events were identified using source separation applying nonnegative matrix factorization deconvolution (NMFD). The algorithm was evaluated using manual annotation of the polysomnographic recordings. According to our results, the sensitivity (Se), and the positive predictive value (PPV) of the developed method to reveal snoring from the Emfit signal were 82.81% and 86.29%, respectively. Compared to other approaches, our method adapts to the individual spectral snoring profile of the subject rather than matching a particular spectral profile, estimates the snoring intensity, and obtains the specific spectral profile of the snores in the epoch. Additionally, no training is necessary. This study suggests that it is possible to detect individual SN events with Emfit mattress, which can be used as a contactless alternative to more conventional methods such as piezo-snore sensors or microphones.