In the computer-aided diagnosis of lung cancer, the automatic segmentation of pulmonary nodules and the classification of benign and malignant tumors are two fundamental tasks. However, deep learning models often overlook the potential benefits of task correlations in improving their respective performances, as they are typically designed for a single task only. Therefore, we propose a multi-task network (MT-Net) that integrates shared backbone architecture and a prediction distillation structure for the simultaneous segmentation and classification of pulmonary nodules. The model comprises a coarse segmentation subnetwork (Coarse Seg-net), a cooperative classification subnetwork (Class-net), and a cooperative segmentation subnetwork (Fine Seg-net). Coarse Seg-net and Fine Seg-net share identical structure, where Coarse Seg-net provides prior location information for the subsequent Fine Seg-net and Class-net, thereby boosting pulmonary nodule segmentation and classification performance. We quantitatively and qualitatively analyzed the performance of the model by using the public dataset LIDC-IDRI. Our results show that the model achieves a Dice similarity coefficient (DI) index of 83.2% for pulmonary nodule segmentation, as well as an accuracy (ACC) of 91.9% for benign and malignant pulmonary nodule classification, which is competitive with other state-of-the-art methods. The experimental results demonstrate that the performance of pulmonary nodule segmentation and classification can be improved by a unified model that leverages the potential correlation between tasks.
18 September 2023 in IEEE Transactions on Instrumentation and Measurement
Lung cancer is a leading cause of cancer death, but its mortality continues to decline substantially, benefiting from early screening and/or treatment of lung nodules. Therefore, the accurate and robust segmentation of pulmonary nodules from lung CT is an essential task. However, automated solution is still challenging due to the high variability, blurred edges and complex background of pulmonary nodules in CT scans. In this paper, we propose a novel scale-aware-based multi-attention guided reverse network (SM-RNet) for pulmonary nodules segmentation, which makes full use of the complementary information from different attention dimensions and scales, and progressively obtains the complete object by reverse erasure manner, consisting of two stages. Stage I performs weighted cross-scale fusion for features with different scale attention to extract the intermediate multi-scale features with channel and scale awareness, stage II adaptively selects features from the most appropriate scale for the target and sequentially mines the details required for the segmentation task by a new scale-guide spatial attention (SSA) block and a new reverse erasure (RE) block. In addition, the model is equipped with two-stage deep supervision. We evaluate the segmentation accuracy of our method by calculating the dice similarity coefficient, jaccard index, Hausdorff distance, recall, specificity and precision on an internal institution dataset from the Fudan University Shanghai Cancer Center (FUSCC) and a public dataset LUng Nodule Analysis 2016 (LUNA16). Our proposed SM-RNet achieves the Dice scores of 89.290 ± 0.040% and 86.496 ± 0.076%, and Hausdorff distance of 5.532 ± 0.186 and 6.131 ± 0.288 for FUSCC and LUNA, respectively. SM-RNet significantly outperforms other SOTA networks. In addition, the visualization results of qualitative analysis show that the network has strong robustness.
Accurate segmentation of lung nodules from pulmonary computed tomography (CT) slices plays a vital role in the analysis and diagnosis of lung cancer. Convolutional Neural Networks (CNNs) have achieved state-of-the-art performance in the automatic segmentation of lung nodules. However, they are still challenged by the large diversity of segmentation targets, and the small inter-class variances between the nodule and its surrounding tissues. To tackle this issue, we propose a features complementary network according to the process of clinical diagnosis, which made full use of the complementarity and facilitation among lung nodule location information, global coarse area, and edge information. Specifically, we first consider the importance of global features of nodules in segmentation and propose a cross-scale weighted high-level feature decoder module. Then, we develop a low-level feature decoder module for edge feature refinement. Finally, we construct a complementary module to make information complement and promote each other. Furthermore, we weight pixels located at the nodule edge on the loss function and add an edge supervision to the deep supervision, both of which emphasize the importance of edges in segmentation. The experimental results demonstrate that our model achieves robust pulmonary nodule segmentation and more accurate edge segmentation.
In this study, we demonstrated a framework for improving the image quality of computational ghost imaging (CGI) that used a conditional generative adversarial network (cGAN). With a set of low-quality images from a CGI system and their corresponding ground-truth counterparts, a cGAN was trained that could generate high-quality images from new low-quality images. The results showed that compared with the traditional method based on compressed sensing, this method greatly improved the image quality when the sampling ratio was low.
The heart is an important organ that maintains human life activities, and its movement reflects its health status. Utilizing electromagnetic waves as a sensing tool, radar sensors enable noncontact measurement of cardiac motion, offering advantages over conventional contact-based methods in terms of comfort, hygiene, and efficiency. In this study, the high-precision displacement detection algorithm of radar is applied to measure cardiac motion. Experimental is conducted using a single out-channel frequency modulated continuous wave (FMCW) radar operating in the ISM frequency band with a center frequency of 24 GHz and a bandwidth of 150 MHz. Since the detection signal is influenced by both respiratory and heartbeat movements, it is necessary to eliminate the respiratory signal from the measurement signal. Firstly, the harmonic composition of the respiratory signal is analyzed, and a method is proposed to calculate the parameters of the respiratory waveform by comparing the respiratory waveform coverage area with the area of the circumscribed rectangle. This allows for determining the number of respiratory harmonics, assisting in determining whether respiratory harmonics overlap with the frequency range of the heartbeat signal. Subsequently, a more accurate cardiac motion waveform is extracted. A reference basis is provided for extracting cardiac health information from radar measurement waveforms by analyzing the corresponding relationship between certain extreme points of the waveform and characteristic positions of the electrocardiogram (ECG) signal. This is achieved by eliminating the fundamental frequency component of the heartbeat waveform to emphasize other spectral components present in the heartbeat signal and comparing the heartbeat waveform, the heartbeat waveform with the fundamental frequency removed, and the heartbeat velocity waveform with synchronized ECG signals.