A control structure design of a three-phase three-leg four-wire grid-tied Distribution Static Synchronous Compensator (DSTATCOM) based on a combined-step-size real-coefficient improved proportionate affine projection sign algorithm (CSS-RIP-APSA) has been presented. The three-phase four-wire DSTATCOM is used for reactive power compensation along with harmonic current minimization. This strategy also helps in load balancing and neutral current compensation. The affine projection sign algorithm (APSA) is a member of the adaptive filter family, which has a slow convergence rate. The conventional adaptive filter deals with the trade-off between the convergence rate and the steady-state error. In the proposed algorithm, the RIP-APSA adaptive filter with two different step sizes has been designed to decrease the computational burden while achieving the advantages of a fast convergence rate and reduced steady-state error. The proposed controller also makes the inverter function a shunt compensator. The controller primarily evaluates the fundamental weight component of distorted load currents. The aim of the proposed system is to compensate for reactive power and to ensure unity power factor during the faulty conditions as well as for unbalancing grid conditions. The proposed control algorithm of the grid-tied DSTATCOM works effectively on the laboratory prototype as verified from the experimental results.
1 December 2022 in International Journal of Power Electronics and Drive Systems (IJPEDS)
The maximum power point tracking (MPPT) has been a popular terminology among those researchers who deal with one of the most available renewable energy resources called solar power. Many researchers have evolved and proposed a lot of techniques for tracking maximum power. But each technique has its pros and cons. Some techniques suffer from complexity as far as implementation is concerned, whereas other techniques lack accuracy. In current research work, it has been investigated the MPPT using Newton Raphson (NR) method, which has not yet received a good attention by researchers. After observing its limitation, this method is modified (i.e., abbreviated as modified Newton Raphson method (MNRM)) to make it suitable for extracting the maximum power from PV module. The feasibility and precision of this method depends upon accurate measurement of temperature and irradiation. By using MNRM, the presumption of initial value is close to the voltage corresponding to maximum power, so it leads faster converging to solution through a few rounds of iterations. In order to validate it, a MATLAB/Simulink model is developed and simulated. The proposed method is incorporated in PV module-fed buck converter so as to explore superior performance.