The implantable cardioverter-defibrillator (ICD) is an effective method to prevent sudden cardiac death in high-risk patients. However, the transvenous lead is incompatible with large-area electrophysiological mapping and cannot accommodate selective multichannel precision stimulations. Moreover, it involves high-energy shocks, resulting in pain, myocardial damage, and recurrences of ventricular tachyarrhythmia (VTA). We present a method for VTA treatment based on subthreshold electrical stimulations using a stretchable epicardial multichannel electrode array, which does not disturb the normal contraction or electrical propagation of the ventricle. In rabbit models with myocardial infarction, the infarction was detected by mapping intracardiac electrograms with the stretchable epicardial multichannel electrode array. Then, VTAs could be terminated by sequential electrical stimuli from the epicardial multichannel electrode array beginning with low-energy subthreshold stimulations. Last, we used these subthreshold stimulations to prevent the occurrence of additional VTAs. The proposed protocol using the stretchable epicardial multichannel electrode array provides opportunities toward the development of innovative methods for painless ICD therapy.
8 October 2019 in International Journal of Heart Failure
Cardiac radioablation is emerging as an alternative option for refractory ventricular arrhythmias. However, the immediate acute effect of high-dose irradiation on human cardiomyocytes remains poorly known. We measured the electrical activities of human induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs) upon irradiation with 0, 20, 25, 30, 40, and 50 Gy using a multi-electrode array, and cardiomyocyte function gene levels were evaluated. iPSC-CMs showed to recover their electrophysiological activities (total active electrode, spike amplitude and slope, and corrected field potential duration) within 3–6 h from the acute effects of high-dose irradiation. The beat rate immediately increased until 3 h after irradiation, but it steadily decreased afterward. Conduction velocity slowed in cells irradiated with ≥25 Gy until 6–12 h and recovered within 24 h; notably, 20 and 25 Gy-treated groups showed subsequent continuous increase. At day 7 post-irradiation, except for cTnT, cardiomyocyte function gene levels increased with increasing irradiation dose, but uniquely peaked at 25–30 Gy. Altogether, high-dose irradiation immediately and reversibly modifies the electrical conduction of cardiomyocytes. Thus, compensatory mechanisms at the cellular level may be activated after the high-dose irradiation acute effects, thereby, contributing to the immediate antiarrhythmic outcome of cardiac radioablation for refractory ventricular arrhythmias.
16 March 2021 in Journal of the American Heart Association
Background: Noninvasive cardiac radioablation is employed to treat ventricular arrhythmia. However, myocardial changes leading to early‐period antiarrhythmic effects induced by high‐dose irradiation are unknown. This study investigated dose‐responsive histologic, ultrastructural, and functional changes within 1 month after irradiation in rat heart. Methods and Results: Whole hearts of wild‐type Lewis rats (N=95) were irradiated with single fraction 20, 25, 30, 40, or 50 Gy and explanted at 1 day or 1, 2, 3, or 4 weeks’ postirradiation. Microscopic pathologic changes of cardiac structures by light microscope with immunohistopathologic staining, ultrastructure by electron microscopy, and functional evaluation by ECG and echocardiography were studied. Despite high‐dose irradiation, no myocardial necrosis and apoptosis were observed. Intercalated discs were widened and disrupted, forming uneven and twisted junctions between adjacent myocytes. Diffuse vacuolization peaked at 3 weeks, suggesting irradiation dose‐responsiveness, which was correlated with interstitial and intracellular edema. CD68 immunostaining accompanying vacuolization suggested mononuclear cell infiltration. These changes were prominent in working myocardium but not cardiac conduction tissue. Intracardiac conduction represented by PR and QTc intervals on ECG was delayed compared with baseline measurements. ST segment was initially depressed and gradually elevated. Ventricular chamber dimensions and function remained intact without pericardial effusion. Conclusions: Mononuclear cell–related intracellular and extracellular edema with diffuse vacuolization and intercalated disc widening were observed within 1 month after high‐dose irradiation. ECG indicated intracardiac conduction delay with prominent ST‐segment changes. These observations suggest that early antiarrhythmic effects after cardiac radioablation result from conduction disturbances and membrane potential alterations without necrosis.