Sofie Bosch

Dr. Sofie Bosch

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2018 in Journal of Pediatric Gastroenterology and Nutrition
Verified
Journal Article
Closed access
SBSofie Bosch
Sofie Bosch
ESEduard A. Struys
Eduard A. Struys
NGNora van Gaal
Nora van Gaal
ABAbdellatif Bakkali
Abdellatif Bakkali
EJErwin W. Jansen
Erwin W. Jansen
TMTim G.J. de Meij
Tim G.J. de Meij

28 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
SBSofie Bosch
Sofie Bosch
RMRenée X. de Menezes
Renée X. de Menezes
SPSuzanne Pees
Suzanne Pees
DWDion J. Wintjens
Dion J. Wintjens
MSMargien Seinen
Margien Seinen
NBNanne De Boer
Nanne De Boer
Sensor drift is a well-known disadvantage of electronic nose (eNose) technology and may affect the accuracy of diagnostic algorithms. Correction for this phenomenon is not routinely performed. The aim of this study was to investigate the influence of eNose sensor drift on the development of a disease-specific algorithm in a real-life cohort of inflammatory bowel disease patients (IBD). In this multi-center cohort, patients undergoing colonoscopy collected a fecal sample prior to bowel lavage. Mucosal disease activity was assessed based on endoscopy. Controls underwent colonoscopy for various reasons and had no endoscopic abnormalities. Fecal eNose profiles were measured using Cyranose 320®. Fecal samples of 63 IBD patients and 63 controls were measured on four subsequent days. Sensor data displayed associations with date of measurement, which was reproducible across all samples irrespective of disease state, disease activity state, disease localization and diet of participants. Based on logistic regression, corrections for sensor drift improved accuracy to differentiate between IBD patients and controls based on the significant differences of six sensors (p = 0.004; p < 0.001; p = 0.001; p = 0.028; p < 0.001 and p = 0.005) with an accuracy of 0.68. In this clinical study, short-term sensor drift affected fecal eNose profiles more profoundly than clinical features. These outcomes emphasize the importance of sensor drift correction to improve reliability and repeatability, both within and across eNose studies.

11 November 2022 in Gut Microbes
Verified
Journal Article
Open access
SBSofie Bosch
Sofie Bosch
Animesh AcharjeeAnimesh Acharjee
Animesh Acharjee
MQMohammed Nabil Quraishi
Mohammed Nabil Quraishi
IBIrene V Bijnsdorp
Irene V Bijnsdorp
PRPatricia Rojas
Patricia Rojas
NBNanne Kh de Boer
Nanne Kh de Boer
Screening for colorectal cancer (CRC) reduces its mortality but has limited sensitivity and specificity. Aims We aimed to explore potential biomarker panels for CRC and adenoma detection and to gai...

18 May 2021 in Alimentary Pharmacology & Therapeutics
Verified
Journal Article
Open access
PDF file
SCSubashini Chandrapalan
Subashini Chandrapalan
SBSofie Bosch
Sofie Bosch
Joaquin CubiellaJoaquin Cubiella
Joaquin Cubiella
JGJordi Guardiola
Jordi Guardiola
PKPeter Kimani
Peter Kimani
RARamesh Arasaradnam
Ramesh Arasaradnam
Summary: Background: Faecal immunochemical test (FIT) is emerging as a valid test to rule‐out the presence of colorectal cancer (CRC). However, the accuracy of FIT is dependent on the cut‐off applied. An additional low‐cost test could improve further detection of CRC.Aims: To evaluate the efficacy of combined FIT and volatile organic compounds (VOC) in the detection of CRC within symptomatic populations.Methods: Systematic reviews on the diagnostic accuracy of FIT and VOC, for the detection of CRC, were updated. Meta‐analyses were performed adopting a bivariate model for sensitivity and specificity. Clinical utility of combined FIT and VOC was estimated using Fagan's nomogram. Post‐test probability of FIT negatives was used as a pre‐test probability for VOC.Results: The pooled sensitivity and specificity of FIT at 10 µg/g faeces, for the detection of CRC, were 0.914 (95% confidence interval [CI] = 0.894‐0.936) and 0.783 (CI = 0.850‐0.696), respectively. For VOC, the sensitivity was 0.837 (CI = 0.781‐0.881) and the specificity was 0.803 (CI = 0.870‐0.712). The area under the curve for FIT and VOC were 0.926 and 0.885, respectively. In a population with 5% CRC prevalence, the estimated probability of having CRC following a negative FIT was 0.5% and following both negative FIT and VOC was 0.1%.Conclusions: In a FIT‐negative symptomatic population, VOC can be a good test to rule‐out the presence of CRC. The estimated probability reduction by 0.4% when both tests being negative offers adequate safety netting in primary care for the exclusion of CRC. The number needed to colonoscope to identify one CRC is eight if either FIT or VOC positive. Cost‐effectiveness and clinical accuracy of this approach will need further evaluation.

15 December 2018 in Journal of Cancer Research and Clinical Oncology
Verified
Journal Article
Closed access
PDF file
SBSofie Bosch
Sofie Bosch
DBDaniel J. Berkhout
Daniel J. Berkhout
ILIlhame Ben Larbi
Ilhame Ben Larbi
TMTim G. de Meij
Tim G. de Meij
NBNanne De Boer
Nanne De Boer

25 June 2019 in Journal of Breath Research
Verified
Journal Article
Closed access
PDF file
SBSofie Bosch
Sofie Bosch
JLJesse P M Lemmen
Jesse P M Lemmen
RMRenée Menezes
Renée Menezes
RHRené van der Hulst
René van der Hulst
JKJohan Kuijvenhoven
Johan Kuijvenhoven
NBNanne De Boer
Nanne De Boer
Introduction : Fecal volatile organic compounds (VOCs) are gaseous metabolic products which are increasingly considered potential non-invasive biomarkers for the detection of various (gastrointestinal) diseases. The influence of lifestyle factors on fecal VOC patterns remains unexplored but is of importance prior to implementation of VOC analysis as a diagnostic tool. The aim of this study was to investigate the effects of age, gender, body mass index, smoking status, dietary preferences, medication use and co-morbidity on fecal VOC patterns. Methods : For this study, fecal samples of patients undergoing a colonoscopy were collected prior to endoscopy. All participants completed a questionnaire on lifestyle factors, co-morbidity and medication use. Patients without colonic abnormalities were included in this study. Fecal VOC patterns were analyzed by means of an electronic nose (eNose) device (Cyranose ® 320). Results : From the 1039 participants willing to participate in the initial study, 211 were eligible as controls. All unique lifestyle variables investigated in this study affected the fecal VOC composition. The strongest influences were caused by low BMI, a vegetarian diet and an active smoking status, whereas the least influence was found for the variables gender, age > 55 years and previous smokers. Discussion : Age, gender, BMI, smoking habits, dietary preferences, co-morbidity and medication use all have unique effects on fecal VOC composition. Future studies should carefully consider this influence on VOC outcome when defining VOC signatures as biomarker for diagnostic purposes.