Background: Avian H5N1 influenza viruses present a challenge in the laboratory environment, as they are difficult to collect from the air due to their small size and relatively low concentration. In an effort to generate effective methods of H5N1 air removal and ensure the safety of laboratory personnel, this study was designed to investigate the characteristics of aerosolized H5N1 produced by laboratory manipulations during research studies. Results: Normal laboratory procedures used to process the influenza virus were carried out independently and the amount of virus polluting the on-site atmosphere was measured. In particular, zootomy, grinding, centrifugation, pipetting, magnetic stirring, egg inoculation, and experimental zoogenetic infection were performed. In addition, common accidents associated with each process were simulated, including breaking glass containers, syringe injection of influenza virus solution, and rupturing of centrifuge tubes. A micro-cluster sampling ambient air pollution collection device was used to collect air samples. The collected viruses were tested for activity by measuring their ability to induce hemagglutination with chicken red blood cells and to propagate in chicken embryos after direct inoculation, the latter being detected by reverse-transcription PCR and HA test. The results showed that the air samples from the normal centrifugal group and the negative-control group were negative, while all other groups were positive for H5N1. Conclusions: Our findings suggest that there are numerous sources of aerosols in laboratory operations involving H5N1. Thus, laboratory personnel should be aware of the exposure risk that accompanies routine procedures involved in H5N1 processing and take proactive measures to prevent accidental infection and decrease the risk of virus aerosol leakage beyond the laboratory.
Cronobacter sakazakii is an emerging pathogen that causes severe and life-threatening conditions including meningitis, bacteremia, and necrotizing enterocolitis. An animal model study for extrapolation of C. sakazakii infection can provide a better understanding of pathogenesis. However, methods for real-time monitoring of the course of C. sakazakii infection in living animals have been lacking. We developed a bioluminescent C. sakazakii strain (ATCC 29544) that can be used for real-time monitoring of C. sakazakii infection in BALB/c mice. C. sakazakii ATCC 29544 mainly colonized brain, liver, spleen, kidney, and gastrointestinal tract, as indicated by bioluminescence imaging. This work provides a novel approach for studying the progression of C. sakazakii infection and evaluating therapeutics in a living mouse model.