Li Zhu

Prof. Li Zhu


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2025 in Discover Sustainability
Verified
Journal Article
Open access
PDF file
SAStahel Serano BIBANG BI OBAM ASSOUMOU
Stahel Serano BIBANG BI OBAM ASSOUMOU
SSStahel Serano
Stahel Serano
LZLi Zhu
Li Zhu
CKChristopher Khayeka-Wandabwa
Christopher Khayeka-Wandabwa
Globally, the built-up areas are witnessing notable exponential growth prompting ecological and ecosystem services shifts. The trajectory is in tune with the increasing recognition that social determinants of health (conditions in which people are born, grow, work, live, worship, and age) affect human health and well-being. As green building (GB) concepts advance globally and people spend more time indoors, both developers and end users have prioritized more thoughtful spaces that promote human health, well-being, and resource efficiency throughout their entire life cycle. The scoping review examines the evolving trends of healthy building standards and their integration into the green building and green building rating system (GBRS) along with how the advances interlink to health and well-being. Twenty-seven studies were included in the review with a focus on green building, GBRS, healthy building, and healthy building standards. Prevailing GBRS for evaluation of green buildings emphasizes indoor environmental quality (IEQ) and indoor air quality (IAQ) with limited incorporation of health attributes notably, WELL standards. There is a compelling need to synchronize green building and rating systems with healthy building standards and rating systems measures to uphold the physical, psychological, and physiological health of a built environment and its occupants at one go in the project cycle. Thus, GBRS for GB ought to prioritize the WELL concept and the interdisciplinary intersections tradeoffs with priority on the lags in nourishment, movement, mind, and community given one health and globalization interplays. The interplays would entail but not be limited to evolving socio-cultural influences (like shared workspace, remote working, and teleworking perception post-COVID-19 pandemic), enabling intelligent technologies among other ecosystem services.

14 March 2011 in Energies
Verified
Journal Article
Open access
PDF file
YZYang Zhiyong
Yang Zhiyong
JZJinli Zhang
Jinli Zhang
LZLi Zhu
Li Zhu
A solar assisted heat pump (SAHP) system was designed by using a roof-integrated solar collector as the evaporator, and then it was demonstrated to provide space heating for a villa in Tianjin, China. A building energy simulation tool was used to predict the space heating load and a three dimensional theoretical model was established to analyze the heat collection performance of the solar roof collector. A floor radiant heating unit was used to decrease the energy demand. The measurement results during the winter test period show that the system can provide a comfortable living space in winter, when the room temperature averaged 18.9 °C. The average COP of the heat pump system is 2.97 and with a maximum around 4.16.

22 April 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
LZLi Zhu
Li Zhu
Chen WangChen Wang
Chen Wang
HNHuang Ning
Huang Ning
YFYu Fu
Yu Fu
ZYZhexing Yan
Zhexing Yan
Indicator-based evaluation systems are critical for guiding and monitoring cities’ sustainable development. Zhangjiakou city is the national renewable energy demonstration zone in China, and is gaining more attention (being the co-host city of the 2022 Winter Olympic Games). It needs to seize the opportunities for its long-term sustainable development. An indicator system was developed to monitor the city’s sustainability. Local governance was integrated into an extended three-pillar evaluation model as the fourth dimension through the involvement of over 30 local government departments. Based on the interpretation of local demands, 118 assessment tools were reviewed and an international indicator inventory of 224 indicators was established. By analyzing the local relevance, 95 indicators were selected and categorized into eight modules (energy and carbon emission, resources and environment, harmony and well-being, economics and inclusion, key industries, innovation and smart, governance and efficiency, and internationalization). However, only 67 indicators were confirmed for value assignments after applicability assessment. Basic performance values (BPVs) were given as achievable goals during the 14th Five-Year Plan (FYP), and the excellent performance values (EPVs) were given towards carbon neutrality. All of the values were peer-reviewed and agreed by the local government while discrepancy still exists on carbon emission.

20 March 2024 in Environmental Monitoring and Assessment
Verified
Journal Article
Closed access
PDF file
LZLi Zhu
Li Zhu
JMJunrong Ma
Junrong Ma
CWChen Wang
Chen Wang
SDSteivan Defilla
Steivan Defilla
ZYZhexing Yan
Zhexing Yan


24 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
LZLi Zhu
Li Zhu
PWPeng Wang
Peng Wang
YHyj HUO
yj HUO
Wei TianWei Tian
Wei Tian
YSYong Sun
Yong Sun
BYBaoquan Yin
Baoquan Yin
Due to the limited available envelope area, height-constrained buildings integrated with photovoltaics require that more attention be given to the effective use of roofs. Thus, it is crucial to study the energy savings potential of previously neglected semitransparent photovoltaic (STPV) skylights. In this paper, the net energy consumption (NEC) of a room with STPV skylights and energy superiority compared to a reference window were investigated. The energy savings potential was then calculated for five representative cases located in different climate zones and daylight zones, according to the mandatory codes to be implemented in April 2022. Through a global sensitivity analysis, the extent to which each component of the NEC affects the energy savings potential was evaluated. The results indicate that STPV skylights exhibit promising energy savings potential in China. In temperate zones with excellent daylight conditions, an energy savings potential of 0.21 to 2.55 can be achieved, while the maximum energy savings rate (ESR) for the other four cases ranges from 0.52 to 1.1. The effect of electricity power generation (EPG) on the energy savings potential is most pronounced, except for that of STPV skylights on sloped roofs in hot summer and cold winter zones with poor daylight.