Jean-Marie Pétémanagnan OUATTARA

Prof. Jean-Marie Pétémanagnan OUATTARA

NANGUI ABROGOUA University
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2021 in Water
Verified
Journal Article
Open access
PDF file
Franck Michaël ZAHUIFranck Michaël ZAHUI
Franck Michaël ZAHUI
JOJean-Marie Pétémanagnan OUATTARA
Jean-Marie Pétémanagnan OUATTARA
MKMahamadou Kamagaté
Mahamadou Kamagaté
LCLacina Coulibaly
Lacina Coulibaly
Alexandros I. StefanakisAlexandros I. Stefanakis
Alexandros I. Stefanakis
Bacteria are frequently studied due to their involvement in pollutants transformation processes during wastewater treatment. In this study, the treatment efficiency, bacteria densities and their vertical profile were investigated in pilot-scale vertical flow constructed wetlands (VFCW) planted with different plant species under a tropical climate in west Africa. Five beds were planted with local plant species, i.e., Andropogon gayanus, Chrysopogon zizanioides, Echinochloa pyramidalis, Pennisetum purpureum and Tripsacum laxum, while one bed remained unplanted. These species have been rarely used in CWs while some (e.g., T. laxum) are tested for the first time. After a 7-month trial, bacteria densities were measured in substrate samples separated into six layers along the bed depth. Plants presence enhanced the bacterial density and VFCW efficiency; the removal rates of organic matter (90.9–95.9%; COD and 95.2–98.5%; BOD5), nitrogen (74.3–84%; TN and 76–84%; NH4-N) and phosphorus (77.4–96.9%; PO4-P) were higher by 5.9–24.1% compared to the control bed, providing an overall excellent treatment performance for a single-stage VFCW system. Small numbers of anaerobic bacteria were obtained in the VFCWs, explaining the low-to-zero NO3-N removal, except for the VFCWs with T. laxum and P. purpureum. Aerobic bacteria decreased from the upper to bottom layers from 17.4 to 0.1 × 106 CFU/g in the planted beds, while anaerobic bacteria increased from 0.1 to 2.1 × 106 CFU/g. Anaerobic bacteria were more abundant in the unplanted than in the planted beds. The total bacteria count was dominated by aerobic bacteria, and decreased from the surface towards the bottom. Overall, the VFCW with P. purpureum demonstrated the highest efficiency, indicating that this design is an effective and sustainable nature-based solution for wastewater treatment in a tropical climate.

16 June 2025 in Journal of Water, Sanitation and Hygiene for Development
Verified
Journal Article
Open access
Franck Michaël ZAHUIFranck Michaël ZAHUI
Franck Michaël ZAHUI
NKN'DA Akoua Alice Koua-Koffi
N'DA Akoua Alice Koua-Koffi
JOJean-Marie Pétémanagnan OUATTARA
Jean-Marie Pétémanagnan OUATTARA
ABAmichalé Jean Cyrille Beda
Amichalé Jean Cyrille Beda
LCLassina Sandotin Coulibaly
Lassina Sandotin Coulibaly
MKMahamadou Kamagaté
Mahamadou Kamagaté
This study examines water, sanitation and hygiene (WASH) facilities in public primary schools in the Department of Man, Côte d'Ivoire. Interviews were conducted with the regional education director and head teachers, and a visual assessment was made of the environment in 158 schools, divided into 36 school groups (SGs) and 10 single schools (SSs). The majority of SGs (77.8–86.1%) had handwashing facilities, water points and latrines. However, very few SSs (30%) had latrines, while most had handwashing facilities and water points, i.e. wells, taps and boreholes, with a greater number of wells in both SSs and SGs. The majority of latrines were of the dry pit type (76.3%), with 4–6 cubicles, separated by sex, and mostly built by international organizations, including UNICEF, which built the largest number. However, 30.2% of the latrines are out of use, mainly due to pressure from the local population and lack of maintenance. Old buckets are mainly used as bins, often in front of classrooms, and the waste is usually burned in the open. Given the variety of interventions, the government needs to introduce standards for WASH in schools and set up a fund to maintain the built infrastructure.

29 May 2025 in American Journal of Environmental Protection
Verified
Journal Article
Open access
PDF file
NSN’LÔh Soro
N’LÔh Soro
JOJean-Marie Pétémanagnan OUATTARA
Jean-Marie Pétémanagnan OUATTARA
ABAmichalé Beda
Amichalé Beda
Franck Michaël ZAHUIFranck Michaël ZAHUI
Franck Michaël ZAHUI
AMAman Messou
Aman Messou
Burning of used tyres is a growing activity in urban areas of Côte d'Ivoire. However, this activity is a source of soil pollution. In this context, this study aims to map the sites where used tyres are burned in the city of Abidjan, to describe this practice and to analyse the associated health and environmental risks. Field observations and interviews were conducted with the local population, garage owners and vulcanisers. In addition, the geographical coordinates of the identified tyres burning sites were recorded using GPS. A total of 50 tyres burning sites were identified in Abidjan, including 12 in Yopougon, 10 in Abobo, 05 in Marcory, 06 in Koumassi, 05 in Port-Bouët, 06 in Attécoubé and 06 in Adjamé. Most of the waste tyres burning sites are located close to economic activities, residential areas and rainwater drainage networks, exposing the surrounding population to risks. Tyres burning is carried out exclusively by men. Most of them are aged between 20 and 40 (59%) and most of them have no formal education (77.15%). This activity produces toxic fumes and ash which contain contaminant, posing significant risks to human health and the environment. This study suggests the importance of regulating informal tyres burning due to its proven risks to public health and the environment. The results of this research should guide public policy promoting environmentally sound alternatives for used tyres management, such as recycling and recovery.

13 September 2025 in Asian Journal of Biotechnology and Bioresource Technology
Verified
Journal Article
Closed access
Franck Michaël ZAHUIFranck Michaël ZAHUI
Franck Michaël ZAHUI
ABAmichalé Jean Cyrille Beda
Amichalé Jean Cyrille Beda
JOJean-Marie Pétémanagnan OUATTARA
Jean-Marie Pétémanagnan OUATTARA
AMAman Messou
Aman Messou
LCLacina Coulibaly
Lacina Coulibaly
Aims: This study examines waste production and management in slaughterhouses in the Côte d'Ivoirean cities of Daloa and Man, as well as its impact on the surrounding waterways in Man. Study Design: The study is experimental in nature and employed a Research and Development (R&D) research design. Place and Duration of Study: Daloa and Man, cities located in the central-western and western regions of Côte d'Ivoire, respectively, Central laboratory of the University of Man, between September and December 2024. Methodology: Data were collected by surveying slaughterhouse managers in both cities of Daloa and Man and analyzing the physical and chemical characteristics of water samples taken from the Koh River near the Man slaughterhouse using a multi-parameter meter and ISO methods. Results: The animals slaughtered are sheep, cattle and goats, with cattle predominating. Nevertheless, between 2020 and 2023, the Daloa slaughterhouse recorded the highest number of animals slaughtered each year: 3,440–9,884 sheep, 9,253–10,374 cattle, and 2,912–4,810 goats. The waste produced at these two slaughterhouses consists of blood, horns, hooves, bones, dung (the contents of the animals' rumen) and wastewater from cleaning. These liquids are mixed during the slaughtering process and then discharged. In Man, this mixture is discharged into the Koh River. In Daloa, however, liquid waste is discharged into the natural environment behind the slaughterhouse. Solid waste, such as dung, is usually mixed with wastewater for disposal at both sites. Other solid waste, such as horns, hooves and bones, is left on site and exposed to scavenging animals, including rats, cats and stray dogs. The discharge point for effluent from the Man slaughterhouse into the Koh River is significantly more contaminated with nutrients and organic matter than the sections upstream and downstream, with average chemical oxygen demand and biochemical oxygen demand concentrations of 3,137.5 mg/L and 1,873.7 mg/L respectively. Average concentrations are 40.1 mg/L for total phosphorus, 30.6 mg/L for orthophosphate, 497.9 mg/L for total nitrogen, 81.9 mg/L for nitrate and 341.6 mg/L for ammonium. Conclusion: The current method of managing slaughterhouse waste in these two cities is seriously damaging their appearance and degrading the water quality of the Koh River in Man. This is also affecting their image as tourist destinations.