Marius Helmedag

Dr. Marius Helmedag

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2020 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Open access
PDF file
MHMarius Helmedag
Marius Helmedag
DHDaniel Heise
Daniel Heise
RERoman Eickhoff
Roman Eickhoff
KKKlas‐Moritz Kossel
Klas‐Moritz Kossel
TGThomas Gries
Thomas Gries
ALAndreas Lambertz
Andreas Lambertz
Surgical sutures are indispensable for a vast majority of operative procedures. An ideal suture is characterized by high tissue compliance without cutting into the mended tissue and optimal biocompatibility. Therefore, we assessed these mechanical and biological properties for novel elastic thermoplastic polyurethane (TPU) and cross‐sectional modified “snowflake” sutures. Circular and “snowflake”‐shaped TPU threads were manufactured and compared to similar surface modified polyvinylidene fluoride (PVDF) sutures. Regular PVDF sutures were used as the control group. Single‐axis tensile test with and without gelatinous tissue surrogates were performed to evaluate the suture incision into the specimens. Biocompatibility was evaluated by subcutaneous implantation (n = 18) in rats for 7 and 21 days. Histology and immunohistology was conducted for assessment of the foreign body reaction. Regular and modified TPU threads showed a significant reduction of incision into the tissue surrogates compared to the control. Both TPU sutures and the modified PVDF sutures achieved comparable biocompatibility versus regular PVDF threads. Detailed histology revealed novel tissue integration into the notches of the surface modified sutures, we termed this newly shaped granuloma “intrafilamentous” granuloma. Elastic TPU threads showed a significant reduction of tissue surrogate incision and suture tension loss. Biocompatibility did not significantly differ from standard PVDF. Histology demonstrated tissue ingrowth following the surface modification of the suture referred to as “intrafilamentous” granuloma. Further in vivo studies are required to illuminate the exact potential of the new sutures to optimize intestinal anastomosis.

Verified
Journal Article
Open access
PDF file
Moritz UhligMoritz Uhlig
Moritz Uhlig
MHMarc Hein
Marc Hein
MHMoriz Aljoscha Habigt
Moriz Aljoscha Habigt
RTRené Tolba
René Tolba
TBTill Braunschweig
Till Braunschweig
MMMare Mechelinck
Mare Mechelinck
Cirrhotic patients often suffer from cirrhotic cardiomyopathy (CCM). Previous animal models of CCM were inconsistent concerning the time and mechanism of injury; thus, the temporal dynamics and cardiac vulnerability were studied in more detail. Rats underwent bile duct ligation (BDL) and a second surgery 28 days later. Cardiac function was assessed by conductance catheter and echocardiography. Histology, gene expression, and serum parameters were analyzed. A chronotropic incompetence (Pd31 < 0.001) and impaired contractility at rest and a reduced contractile reserve (Pd31 = 0.03, Pdob-d31 < 0.001) were seen 31 days after BDL with increased creatine (Pd35, Pd42, and Pd56 < 0.05) and transaminases (Pd31 < 0.001). A total of 56 days after BDL, myocardial fibrosis was seen (Pd56 < 0.001) accompanied by macrophage infiltration (CD68: Pgroup < 0.001) and systemic inflammation (TNFα: Pgroup < 0.001, white blood cell count: Pgroup < 0.001). Myocardial expression of peroxisome proliferator-activated receptor gamma coactivator 1-alpha (PGC1α) was increased after 31 (Pd31 < 0.001) and decreased after 42 (Pd42 < 0.001) and 56 days (Pd56 < 0.001). Caspase-3 expression was increased 31 and 56 days after BDL (Pd31 = 0.005; Pd56 = 0.005). Structural changes in the myocardium were seen after 8 weeks. After the second surgery (second hit), transient myocardial insufficiency with secondary organ dysfunction was seen, characterized by reduced contractility and contractile reserve.

31 May 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
MHMarius Helmedag
Marius Helmedag
DHDaniel Heise
Daniel Heise
RERoman M. Eickhoff
Roman M. Eickhoff
Sophia M. SchmitzSophia M. Schmitz
Sophia M. Schmitz
MMMare Mechelinck
Mare Mechelinck
ALAndreas Lambertz
Andreas Lambertz
(1) Introduction: The intraperitoneal onlay mesh technique (IPOM) is widely used to repair incisional hernias. This method has advantages but suffers from complications due to intraperitoneal adhesion formation between the mesh and intestine. An ideal mesh minimizes adhesions and shows good biocompatibility. To address this, newly developed multifilamentous polyethylene (PET) meshes were constructed from sub-macrophage-sized monofilaments and studied regarding biocompatibility and adhesion formation. (2) Methods: We investigated fine (FPET, 72 filaments, 11 µm diameter each) and ultra-fine multifilament (UFPET, 700 filaments, 3 µm diameter each) polyethylene meshes for biocompatibility in subcutaneous implantation in rats. Adhesion formation was analyzed in the IPOM position in rabbits. Geometrically identical mono-filamentous polypropylene (PP) Bard Soft® PP meshes were used for comparison. Histologic and immune-histologic foreign body reactions were assessed in 48 rats after 7 or 21 days (four mesh types, with two different mesh types per rat; n = 6 per mesh type). Additionally, two different mesh types each were placed in the IPOM position in 24 rabbits to compile the Diamond peritoneal adhesion score after the same timeframes. The biocompatibility and adhesion score differences were analyzed with the Kruskal–Wallis nonparametric statistical test. (3) Results: Overall, FPET and, especially, UFPET showed significantly smaller foreign body granulomas compared to PP meshes. Longer observation periods enhanced the differences. Immunohistology showed no significant differences in the cellular immune response and proliferation. UFPET demonstrated significantly reduced peritoneal adhesion formation compared to all other tested meshes after 21 days. (4) Conclusions: Overall, FPET and, especially, UFPET demonstrated their suitability for IPOM hernia meshes in animal models by improving major aspects of the foreign body reaction and reducing adhesion formation.

22 January 2020 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
RERoman Eickhoff
Roman Eickhoff
DHDaniel Heise
Daniel Heise
AKAndreas Kroh
Andreas Kroh
MHMarius Helmedag
Marius Helmedag
UKUwe Klinge
Uwe Klinge
ALAndreas Lambertz
Andreas Lambertz

24 July 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
Sophia M. SchmitzSophia M. Schmitz
Sophia M. Schmitz
MHMarius Helmedag
Marius Helmedag
AKAndreas Kroh
Andreas Kroh
DHDaniel Heise
Daniel Heise
UKUwe Klinge
Uwe Klinge
RERoman M. Eickhoff
Roman M. Eickhoff
Background: Synthetic mesh material is of great importance for surgical incisional hernia repair. The physical and biochemical characteristics of the mesh influence mechanical stability and the foreign body tissue reaction. The influence on bacterial infections, however, remains ill-defined. The aim of the present study was to evaluate the influence of a modified mesh structure with variation in filament linking on the occurrence of bacterial infection that is indicated by the occurrence of CD68+, CD4+, and CD8+ cells in two different materials. Methods: A total of 56 male Sprague Dawley rats received a surgical mesh implant in a subcutaneous abdominal position. The mesh of two different polymers (polypropylene (PP) and polyvinylidenfluoride (PVDF)) and two different structures (standard structure and bold structure with higher filament linking) were compared. During the implantation, the meshes were infected with Staphylococcus (S.) aureus. After 7 and 21 days, meshes were explanted, and the early and late tissue responses to infection were histologically evaluated. Results: Overall, the inflammatory tissue response was higher at 7 days when compared to 21 days. At 7 days, PP meshes of the standard structure (PP-S) showed the strongest inflammatory tissue response in comparison to all the other groups. At 21 days, no statistically significant difference between different meshes was detected. CD8+ cytotoxic T cells showed a significant difference at 21 days but not at 7 days. PP meshes of both structures showed a higher infiltration of CD8+ T cells than PVDF meshes. CD4+ T helper cells differed at 7 days but not at 21 days, and PVDF meshes in a bold structure showed the highest CD4+ T cell count. The number of CD68+ macrophages was also significantly higher in PP meshes in a standard structure when compared to PVDF meshes at 21 days. Conclusion: The inflammatory tissue response to S. aureus infection appears to be highest during the early period after mesh implantation. PP meshes showed a higher inflammatory response than PVDF meshes. The mesh material appears to be more important for the risk of infection than the variation in filament linking.

8 October 2020 in Journal of Biomaterials Applications
Verified
Journal Article
Closed access
PDF file
RERoman Marius Eickhoff
Roman Marius Eickhoff
AKAndreas Kroh
Andreas Kroh
SESimon Eickhoff
Simon Eickhoff
DHDaniel Heise
Daniel Heise
MHMarius Helmedag
Marius Helmedag
ALAndreas Lambertz
Andreas Lambertz
Background: The incidence of incisional hernia is with up to 30% one of the frequent long-term complication after laparotomy. After establishing minimal invasive operations, the laparoscopic intraperitoneal onlay mesh technique (lap. IPOM) was first described in 1993. Little is known about the foreign body reaction of IPOM-meshes, which covered a defect of the parietal peritoneum. This is becoming more important, since IPOM procedure with peritoneal-sac resection and hernia port closing (IPOM plus) is more frequently used. Methods: In 18 female minipigs, two out of three Polyvinylidene-fluoride (PVDF) -meshes (I: standard IPOM; II: IPOM with modified structure [bigger pores]; III: IPOM with the same structure as IPOM II + degradable hydrogel-coating) were placed in a laparoscopic IPOM procedure. Before mesh placement, a 2x2cm peritoneal defect was created. After 30 days, animals were euthanized, adhesions were evaluated by re-laparoscopy and mesh samples were explanted for histological and immunohistochemichal investigations. Results: All animals recovered after implantation and had no complications during the follow-up period. Analysing foreign body reaction, the IPOM II mesh had a significant smaller inner granuloma, compared to the other meshes (IPOM II: 8.4 µm ± 1.3 vs. IPOM I 9.1 µm ± 1.3, p < 0.001). The degradable hydrogel coating does not prevent adhesions measured by Diamond score (p = 0.46). A peritoneal defect covered by a standard or modified IPOM mesh was a significant factor for increasing foreign body granuloma, the amount of CD3+ lymphocytes, CD68+ macrophages and decrease of pore size. Conclusion: A peritoneal defect covered by IPOM prostheses leads to an increased foreign body reaction compared to intact peritoneum. Whenever feasible, a peritoneal defect should be closed accurately before placing an IPOM-mesh to avoid an excessive foreign body reaction and therefore inferior biomaterial properties of the prosthesis.