Remote monitoring and evaluation of human motion during daily life require accurate extraction of kinematic quantities of body segments. Current approaches use inertial sensors that require numerical time differentiation to access the angular acceleration vector, a mathematical operation that greatly increases noise in the acceleration value. Here we introduce a wearable sensor that utilises a spatially defined cluster of inertial measurement units on a rigid base for directly measuring the angular acceleration vector. For this reason, we used computational modelling and experimental data to demonstrate that our new sensor configuration improves the accuracy of tracking angular acceleration vectors. We confirmed the feasibility of tracking human movement by automatic assessment of experimental fall initiation and balance recovery responses. The sensor therefore presents an opportunity to pioneer reliable assessment of human movement and balance in daily life.
The assessment of the force–length relationship under mechanical loading is widely used to evaluate the mechanical properties of tendons and to gain information about their adaptation, function, and injury. This study aimed to provide a time-efficient ultrasound method for assessing Achilles tendon mechanical properties. On two days, eleven healthy young non-active adults performed eight maximal voluntary isometric ankle plantarflexion contractions on a dynamometer with simultaneous ultrasonographic recording. Maximal tendon elongation was assessed by digitizing ultrasound images at rest and at maximal tendon force. Achilles tendon stiffness index was calculated from the ratio of tendon force-to-strain. No within- and between-day differences were detected between the proposed method and manual frame by frame tracking in Achilles tendon maximal force, maximal elongation, maximal strain, and stiffness index. The overall coefficient of variation between trials ranged from 3.4% to 10.3% and average difference in tendon tracking between methods was less than 0.6% strain. Furthermore, an additional assessment demonstrated significant differences between elite athletes, healthy young, and older adults in Achilles tendon force and stiffness index. Hence, the analysis has the potential to reliably and accurately monitor changes in Achilles tendon mechanical properties due to aging and altered mechanical loading in a time-efficient manner.
5 March 2025 in European Journal of Applied Physiology
Our objective was to explore how the potential for energy transfer between the ankle and knee joint via the biarticular gastrocnemii muscles is modulated during unpredictable and adapted trip-like and drop-like gait perturbations. Using kinematic parameters of the ankle and knee joints, the energy transfer potential between the two joints was determined as the fraction of contact time when the ankle and knee joint angles are in-phase. Additionally, the electromyographic activity of the gastrocnemius medialis and lateralis were captured during the drop-like perturbations. The energy transfer potential increased 1.6-fold in the trip-like and 2.5-fold in the drop-like perturbations compared to unperturbed walking, indicating a relevant involvement of biarticular mechanisms in maintaining body stability. The activation of the gastrocnemii was high (50–60% of a maximum voluntary contraction) in the phases of ankle-to-knee and knee-to-ankle joint energy transfer, which suggests a relevant contribution of biarticular mechanisms to the management of the body’s energy during the drop-like perturbations. Considering the similar ankle-to-knee joint energy transfer potential compared to unperturbed walking, the higher activation of the gastrocnemii muscles in the first 20% of the stance indicates a greater contribution of biarticular mechanisms to the absorption of body energy in the unpredictable perturbations.
Use of head-mounted displays (HMDs) and hand-held displays (HHDs) may affect the effectiveness of stability control mechanisms and impair resistance to falls. This study aimed to examine whether the ability to control stability during locomotion is diminished while using HMDs and HHDs. Fourteen healthy adults (21–46 years) were assessed under single-task (no display) and dual-task (spatial 2-n-back presented on the HMD or the HHD) conditions while performing various locomotor tasks. An optical motion capture system and two force plates were used to assess locomotor stability using an inverted pendulum model. For perturbed standing, 57% of the participants were not able to maintain stability by counter-rotation actions when using either display, compared to the single-task condition. Furthermore, around 80% of participants (dual-task) compared to 50% (single-task) showed a negative margin of stability (i.e., an unstable body configuration) during recovery for perturbed walking due to a diminished ability to increase their base of support effectively. However, no evidence was found for HMDs or HHDs affecting stability during unperturbed locomotion. In conclusion, additional cognitive resources required for dual-tasking, using either display, are suggested to result in delayed response execution for perturbed standing and walking, consequently diminishing participants’ ability to use stability control mechanisms effectively and increasing the risk of falls.
Accurate and automatic assessments of body segment kinematics via wearable sensors are essential to provide new insights into the complex interactions between active lifestyle and fall risk in various populations. To remotely assess near-falls due to balance disturbances in daily life, current approaches primarily rely on biased questionnaires, while contemporary data-driven research focuses on preliminary fall-related scenarios. Here, we worked on an automated framework based on accurate trunk kinematics, enabling the detection of near-fall scenarios during locomotion. Using a wearable inertial measurement cluster in conjunction with evaluation algorithms focusing on trunk angular acceleration, the proposed sensor-framework approach revealed accurate distinguishment of balance disturbances related to trips and slips, thereby minimising false detections during activities of daily living. An important factor contributing to the framework’s high sensitivity and specificity for automatic detection of near-falls was the consideration of the individual’s gait characteristics. Therefore, the sensor-framework presents an opportunity to substantially impact remote fall risk assessment in healthy and pathological conditions outside the laboratory.
Differences in the adaptation processes between muscle and tendon in response to mechanical loading can lead to non-uniform mechanical properties within the muscle-tendon unit (MTU), potentially increasing injury risk. The current study analysed the mechanical properties of the triceps surae (TS) MTU in 10 young (YS; 22 ± 3 yrs) and 10 older (OS; age 65 ± 8 yrs; i.e. master) (inter)national level sprinters and 11 young recreationally active adults (YC; 23 ± 3 yrs) to detect possible non-uniformities in muscle and tendon adaptation due to habitual mechanical loading and ageing. Triceps surae muscle strength, tendon stiffness and maximal tendon strain were assessed in both legs during maximal voluntary isometric plantarflexion contractions via dynamometry and ultrasonography. Irrespective of the leg, OS and YC in comparison to YS demonstrated significantly (P < 0.05) lower TS muscle strength and tendon stiffness, with no differences between OS and YC. Furthermore, no group differences were detected in the maximal tendon strain (average of both legs: OS 3.7 ± 0.8%, YC 4.4 ± 0.8% and YS 4.3 ± 0.9%) as well as in the inter-limb symmetry indexes in muscle strength, tendon stiffness and maximal tendon strain (range across groups: -5.8 to 4.9%; negative value reflects higher value for the non-preferred leg). Thus, the findings provide no clear evidence for a disruption in the TS MTU uniformity in master sprinters, demonstrating that ageing tendons can maintain their integrity to meet the increased functional demand due to elite sports.