Aria M Jamshidi

Dr. Aria M Jamshidi

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in World Neurosurgery
Verified
Journal Article
Closed access
LDLong Di
Long Di
DEDaniel G. Eichberg
Daniel G. Eichberg
KHKevin Huang
Kevin Huang
ASAshish H. Shah
Ashish H. Shah
AJAria M Jamshidi
Aria M Jamshidi
SGSakir H. Gultekin
Sakir H. Gultekin

20 November 2020 in The International Journal of Medical Robotics and Computer Assisted Surgery
Verified
Journal Article
Closed access
PDF file
AJAria M Jamshidi
Aria M Jamshidi
DMDustin H Massel
Dustin H Massel
JLJason I Liounakos
Jason I Liounakos
ZSZmira Silman
Zmira Silman
CGChristopher R Good
Christopher R Good
MWMichael Y Wang
Michael Y Wang

2 October 2022 in World Neurosurgery
Verified
Journal Article
Closed access
NKNickalus R. Khan
Nickalus R. Khan
TETurki Elarjani
Turki Elarjani
AJAria M Jamshidi
Aria M Jamshidi
SCStephanie H. Chen
Stephanie H. Chen
CBClifford S. Brown
Clifford S. Brown
JMJacques J. Morcos
Jacques J. Morcos

1 December 2020 in World Neurosurgery
Verified
Journal Article
Closed access
AJAria M Jamshidi
Aria M Jamshidi
DEDaniel G. Eichberg
Daniel G. Eichberg
RKRicardo J. Komotar
Ricardo J. Komotar
MIMichael Ivan
Michael Ivan

8 October 2021 in Operative Neurosurgery
Verified
Journal Article
Closed access
PDF file
AJAria M Jamshidi
Aria M Jamshidi
VMVyacheslav Makler
Vyacheslav Makler
MWMichael Y Wang
Michael Y Wang
Augmented reality (AR) is a novel technology for spine navigation. This tracking camera-integrated head-mounted display (HMD) represents a novel stereotactic computer navigation modality that has demonstrated excellent precision and accuracy with spinal instrumentation. 1 Standard computer-assisted spine navigation systems have two major shortcomings: attention shift and line-of-sight limitations. The HMD allows visualization of the surgical field and navigation data concurrently in the same field of view. 2,3 However, the use of AR in spine surgery has been limited to use for instrumentation, not for endoscopy. Fully endoscopic transforaminal interbody fusion under conscious sedation is an effective treatment option for degenerative spondylolisthesis and spinal stenosis. Although this technique has a steep learning curve, the advantages are vast, including preservation of normal tissue, smaller incisional requirement, and reduced postoperative pain, all enabling rapid recovery after surgery. As with other endoscopic spine surgeries, this procedure has a steep learning curve and requires a robust understanding of foraminal anatomy in order to safely access the disc space. 4,5 However, with the introduction of AR, the safety and precision of this procedure could be greatly improved upon. In this video, we present a case of a 60-yr-old female who presented with a grade 1 spondylolisthesis and severe spinal stenosis and was treated with an L4-L5 interbody fusion. All instrumentation steps and localization for the endoscopic portion of the case were performed with assistance from the AR-HMD system. Informed written consent was obtained from the patient. The participant and any identifiable individuals consented to the publication of his/her image.

14 November 2022 in Neurosurgery
Verified
Journal Article
Closed access
AJAria M Jamshidi
Aria M Jamshidi
SSSauson Soldozy
Sauson Soldozy
ALAllan D. Levi
Allan D. Levi
BACKGROUND: Lumbar pars defects are common in adolescent athletes and are often due to recurrent axial loading and traumatic stressors. OBJECTIVE: To present an updated case series of young athletes who underwent percutaneous direct pars repair after failure of conservative management. METHODS: A single-center, nonrandomized, retrospective observation study of athletes who were referred for minimally invasive direct pars repair after failure of at least 6 months of conservative management was performed. Summary demographic information, clinical features of presentation, perioperative and intraoperative radiographic imaging, and visual analog scale back pain scores were collected and analyzed. RESULTS: A total of 21 patients were included (mean age [± SD] 17.47 ± 3.02 years, range 14-25 years), 6 of whom were female (29%). All patients presented with bilateral pars fractures, with L5 being the most frequent level involved (n = 13). The average follow-up time was 31.52 ± 9.38 months (range 3-110 months). The visual analog scale score for back pain was significantly reduced from 7.62 ± 1.83 preoperatively to 0.28 ± 0.56 at the final postoperative examination (P < .01). Fusion was noted in 20 of the 21 patients on final follow-up (95%). CONCLUSION: Percutaneous direct pars repair is a safe and effective means in treating young adolescents who have failed conservative management. The advantages included minimized muscle and soft tissue dissection, reduced blood loss, and early mobilization and recovery. In young athletes who desire return to high-level physical activity, this surgical technique is of particular benefit and should be considered in this patient population.