Keith Perkins

Dr. Keith Perkins


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 January 2013 in Nano Letters
Verified
Journal Article
Closed access
KPKeith Perkins
Keith Perkins
AFA. L. Friedman
A. L. Friedman
ECE. Cobas
E. Cobas
PCP. M. Campbell
P. M. Campbell
GJG. G. Jernigan
G. G. Jernigan
BJB. T. Jonker
B. T. Jonker

13 May 2016 in Nanoscale
Verified
Journal Article
Closed access
PDF file
AFAdam L. Friedman
Adam L. Friedman
KPKeith Perkins
Keith Perkins
AHAubrey T. Hanbicki
Aubrey T. Hanbicki
JCJames C. Culbertson
James C. Culbertson
PCPaul M. Campbell
Paul M. Campbell
Ultra-thin transition metal dichalcogenides (TMDs) films show remarkable potential for use in chemical vapor sensing devices. Electronic devices fabricated from TMD films are inexpensive, inherently flexible, low-power, amenable to industrial-scale processing because of emergent growth techniques, and have shown high sensitivity and selectivity to electron donor analyte molecules important for explosives and nerve gas detection. However, for devices reported to date, the conductance response to chemical vapors is dominated by Schottky contacts, to the detriment of the sensitivity, selectivity, recovery, and obscuring their intrinsic behavior. Here, we use contact engineering to transition the contacts in a MoS2 FET-based chemical vapor sensor to the 1T conducting phase, while leaving the channel in the 2H semiconducting state, and thus providing Ohmic contacts to the film. We demonstrate that the resultant sensors have much improved electrical characteristics, are more selective, and recover fully after chemical vapor exposure—all major enhancements to previously MoS2 sensor devices. We identify labile nitrogen-containing electron donors as the primary species that generate a response in MoS2, and we study the dynamics of the sensing reactions, identifying two possible qualitative models for the chemical sensing reaction.

23 October 2014 in IEEE Sensors Journal
Verified
Journal Article
Closed access
ASArthur W. Snow
Arthur W. Snow
KPKeith Perkins
Keith Perkins
MAMario G. Ancona
Mario G. Ancona
JRJeremy T. Robinson
Jeremy T. Robinson
ESEric S. Snow
Eric S. Snow
EFEdward E. Foos
Edward E. Foos
Although robust chemical vapor detection by chemielectric point sensors remains as a largely unmet challenge at present, the best performance to date and the most likely avenue for future progress is with sensor designs in which the transductive element is a disordered nanostructured material. We here review the evidence for this claim, with illustrations drawn from recent work on sensors made from gold nanoparticles, carbon nanotubes, and reduced graphene oxide nanoplatelets. These examples can be regarded as being prototypical of disordered nanostructured films formed of primitive objects that are nanoscopic in 3-D, 2-D, and 1-D, respectively.

4 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JNJongBong Nah
JongBong Nah
KPKeith Perkins
Keith Perkins
ELEvgeniya Hristova Lock
Evgeniya Hristova Lock
ANAnindya Nath
Anindya Nath
ABAnthony Boyd
Anthony Boyd
MRMulpuri V Rao
Mulpuri V Rao
Chemiresistive graphene sensors are promising for chemical sensing applications due to their simple device structure, high sensitivity, potential for miniaturization, low-cost, and fast response. In this work, we investigate the effect of (1) ZnO nanoparticle functionalization and (2) engineered defects onto graphene sensing channel on device resistance and low frequency electrical noise. The engineered defects of interest include 2D patterns of squares, stars, and circles and 1D patterns of slots parallel and transverse to the applied electric potential. The goal of this work is to determine which devices are best suited for chemical sensing applications. We find that, relative to pristine graphene devices, nanoparticle functionalization leads to reduced contact resistance but increased sheet resistance. In addition, functionalization lowers 1/f current noise on all but the uniform mesa device and the two devices with graphene strips parallel to carrier transport. The strongest correlations between noise and engineering defects, where normalized noise amplitude as a function of frequency f is described by a model of AN/fγ, are that γ increases with graphene area and contact area but decreases with device total perimeter, including internal features. We did not find evidence of a correlation between the scalar amplitude, AN, and the device channel geometries. In general, for a given device area, the least noise was observed on the least-etched device. These results will lead to an understanding of what features are needed to obtain the optimal device resistance and how to reduce the 1/f noise which will lead to improved sensor performance.