Quantum non-Gaussian mechanical states are already required in a range of applications. The discrete building blocks of such states are the energy eigenstates—Fock states. Despite progress in their preparation, the remaining imperfections can still invisibly cause loss of the aspects critical for their applications. We derive and apply the most challenging hierarchy of quantum non-Gaussian criteria on the characterization of single trapped-ion oscillator mechanical Fock states with up to 10 phonons. We analyze the depth of these quantum non-Gaussian features under intrinsic mechanical heating and predict their requirement for reaching quantum advantage in the sensing of a mechanical force.
19 January 2000 in Measurement Science and Technology
The authors discuss an increase in the precision of a laser interferometer based on the phase division of the fringe using a single-frequency laser for a distance measurement in the subnanometre range. The resolution of the interferometer is extended by using four paths of the laser beam across the measurement arm of the Michelson interferometer and by subsequent electronic division to the total resolution /2048. The technique fulfils the expectation that the influence of the fringe distortion caused by a phase difference of /2 between two quadrature signals and the difference of the intensities will be lower. A further improvement of the linearity can be achieved by using a mathematical method, which is based on the real-time measurement of parameters of the detected interferometer fringe and an optimal approximation of the quadrature signals obtained by using a conical section. The obtained parameters are transformed from the analytical form to the parametric form of the equation of the conical section and an inverse function is established. Reproducible measurements with an error of less than 0.5 nm are available now.
We have proposed an approach to the interference phase extraction in the homodyne laser interferometry. The method employs a series of computational steps to reconstruct the signals for quadrature detection from an interference signal from a non-polarising interferometer sampled by a simple photodetector. The complexity trade-off is the use of laser beam with frequency modulation capability. It is analytically derived and its validity and performance is experimentally verified. The method has proven to be a feasible alternative for the traditional homodyne detection since it performs with comparable accuracy, especially where the optical setup complexity is principal issue and the modulation of laser beam is not a heavy burden (e.g., in multi-axis sensor or laser diode based systems).
In this contribution we focus on laser frequency noise properties and their influence on the interferometric displacement measurements. A setup for measurement of laser frequency noise is proposed and tested together with simultaneous measurement of fluctuations in displacement in the Michelson interferometer. Several laser sources, including traditional He-Ne and solid-state lasers, and their noise properties are evaluated and compared. The contribution of the laser frequency noise to the displacement measurement is discussed in the context of other sources of uncertainty associated with the interferometric setup, such as, mechanics, resolution of analog-to-digital conversion, frequency bandwidth of the detection chain, and variations of the refractive index of air.
The influence of the refractive index of air has proven to be a major problem on the road to improvement of the uncertainty in interferometric displacement measurements. We propose an approach with two counter-measuring interferometers acting as a combination of tracking refractometer and a displacement interferometer referencing the wavelength of the laser source to a mechanical standard made of a material with ultra-low thermal expansion. This technique combines length measurement within a specified range with measurement of the refractive index fluctuations in one axis. Errors caused by different position of the interferometer laser beam and air sensors are thus eliminated. The method has been experimentally tested in comparison with the indirect measurement of the refractive index of air in a thermal controlled environment. Over a 1 K temperature range an agreement on the level of 5 × 10−8 has been achieved.
Challenging experiments for tests in fundamental physics require highly coherent optical frequency references with suppressed phase noise from hundreds of kHz down to μHz of Fourier frequencies. It can be achieved by remote synchronization of many frequency references interconnected by stabilized optical fibre links. Here we describe the path to realize a delocalized optical frequency reference for spectroscopy of the isomeric state of the nucleus of Thorium-229 atom. This is a prerequisite for the realization of the next generation of an optical clock – the nuclear clock. We present the established 235 km long phase-coherent stabilized cross-border fibre link connecting two delocalized metrology laboratories in Brno and Vienna operating highly-coherent lasers disciplined by active Hydrogen masers through optical frequency combs. A significant part (up to tens of km) of the optical fibre is passing urban combined collectors with a non-negligible level of acoustic interference and temperature changes, which results in a power spectral density of phase noise over 105 rad2· Hz-1. Therefore, we deploy a digital signal processing technique to suppress the fibre phase noise over a wide dynamic range of phase fluctuations. To demonstrate the functionality of the link, we measured the phase noise power spectral density of a remote beat note between two independent lasers, locked to high-finesse stable resonators. Using optical frequency combs at both ends of the link, a long-term fractional frequency stability in the order of 10−15 between local active Hydrogen masers was measured as well. Thanks to this technique, we have achieved reliable operation of the phase-coherent fibre link with fractional stability of 7 × 10−18 in 103 s.