Yaoyao Liao

Yaoyao Liao

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 January 2022 in Machines
Verified
Journal Article
Open access
PDF file
HZHeng Zhang
Heng Zhang
YLYaoyao Liao
Yaoyao Liao
ZTZe Tao
Ze Tao
ZLZisheng Lian
Zisheng Lian
RZRuihao Zhao
Ruihao Zhao
In the field of fully mechanized coal mining equipment, the hydraulic valve used in the hydraulic support is an on/off directional valve. There are many problems caused by the valve such as large pressure shock and discontinuous flow control. Therefore, a novel two-position three-way hydraulic proportional valve suitable for high-pressure and large-flow conditions is proposed to overcome the above problems. The novel valve utilizes a two-stage structure and the displacement follow-up principle is adopted between the pilot stage and the main stage to meet proportional control. In this paper, a simulation model of the novel proportional valve was established after a simplified analysis of the structural principle. Its reliability and the feasibility of the design were verified by the test results under different working conditions. Then, the step response characteristics of the proportional valve under different strokes were predicted and analyzed. Nonlinear characteristics were presented, and the closing time was shorter than the opening time because of the influence of nonlinear flow force. Under different ramp signals, the displacement of the main inlet spool was always approximately equal to the displacement of the pilot stage. Then, the motion relationship between the pilot stage and the main stage was studied, and the influence of the structural parameters on the stability was analyzed.

5 January 2024 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
YLYaoyao Liao
Yaoyao Liao
WZWenbo Zhao
Wenbo Zhao
JFJiling Feng
Jiling Feng
ZLZisheng Lian
Zisheng Lian
The 3/2 water proportional directional valve (PDV) is an important hydraulic component to ensure a precise, low impact, and safety control of hydraulic powered roof support, which has been a technical challenge facing to coal mining industry for many years. To address this issue, a new 3/2 water PDV is developed. The valve includes a novel three-core follow-up servo mechanism consisting of three key components: the pilot inlet valve, the pilot outlet valve, and the main inlet spool. This mechanism enables precise and reliable opening, and closing capacity of the valve. The prototype is manufactured and the performance test is conducted to improve the control performance of the new water PDV. During the test, two significant discoveries are made. First, it is determined that the control chamber of the main inlet spool must be in the predischarge state at the initial time to ensure adequate closing capacity of the new valve during the returning process. Second, it is found that the continuous small-step control mode can better cope with the friction and is more effective in achieving quick and smooth following characteristics of the three valve cores in the opening process, compared with the ramp control mode.

1 September 2019 in International Journal of Applied Electromagnetics and Mechanics
Verified
Journal Article
Closed access
PDF file
YLYaoyao Liao
Yaoyao Liao
ZLZisheng Lian
Zisheng Lian
HYHongbing Yuan
Hongbing Yuan
JFJiling Feng
Jiling Feng
HCHongwei Cui
Hongwei Cui
The solenoid valve used on the hydraulic roof support in the coal mine is an intrinsically safe solenoid. It requires the solenoid valve to achieve large electromagnetic force at low current. The load can not be driven if the current is too low, while a large temperature rise and energy loss would occur in the form of heat if the current is too high. In order to solve this contradictory problem, the load force of the solenoid valve was analyzed first. Then the ANSYS models of the solenoid were established to carry out the simulation jobs. The effects of the three parameters, the sleeve length, the seat length and the boss height, on the electromagnetic forces and magnetic fields were researched so as to optimize the three parameters. The static and dynamic characteristics of the optimized solenoid valve were also studied. An experimental setup was established to verify the simulation results finally. Results show that the simulation values are in good agreement with the experimental values. The peak value of starting current and holding current is small and the solenoid responses rapidly. This study proves the accuracy and reliability of the simulation models and the methods. It also provides valuable references for the design and optimization of the intrinsically safe solenoid valve.

13 July 2022 in Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering
Verified
Journal Article
Closed access
YLYaoyao Liao
Yaoyao Liao
ZTZe Tao
Ze Tao
ZLZisheng Lian
Zisheng Lian
An 800-L/min high-flow water cartridge poppet valve with the commonly used single feed channel was designed to meet the moving speed of the hydraulic powered roof support in the coal mine. Mathematical model was used to explore the dynamic displacement of the valve, and the experimental displacement was measured to verify the accuracy of the simulation value. However, an interesting phenomenon occurred that the experimental opening and closing time of the valve becomes longer and longer with the increase of flow, even vibration appears when the flow is up to 800 L/min, and the simulation error is also getting bigger. To find the reason and solutions, the computational fluid dynamics technology is used. It is discovered that the valve is subjected to radial imbalanced force that is not considered in the initial mathematical model, which leads to big simulation error at high flow condition. Then, the new mathematical model is proposed. The relative simulation error of the response time decreases to 11.7% from 33.3% in the opening process and decreases to 4.6% from 76.9% in the closing process at 800 L/min. A symmetrical dual channel is designed to improve the performance of the valve. The imbalanced force on the dual-channel valve is 63.9% lower than that of the original valve, and the corresponding opening and closing time decreases by 37.5% and 69%, respectively. Furthermore, a double channel valve with auxiliary passage is proposed for super high flow valves. The innovation of this study is correcting the mathematical model by considering the additional radial imbalanced force induced by the asymmetrical flow channel of the valve. It is of great help to successful design of the 800-L/min water directional valve. The case study systematically provides reference for design, failure analysis, and optimization of new products in fluid engineering.

2 September 2025 in Journal of the Brazilian Society of Mechanical Sciences and Engineering
Verified
Journal Article
Closed access
PDF file
GWGuangyao Wei
Guangyao Wei
YLYaoyao Liao
Yaoyao Liao
CYChangwang Yang
Changwang Yang
JHJiale Han
Jiale Han

22 October 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
WXWentao Xi
Wentao Xi
YLYaoyao Liao
Yaoyao Liao
ZLZisheng Lian
Zisheng Lian
RLRunze Li
Runze Li
FYFang Yang
Fang Yang
MJMingqi Jiang
Mingqi Jiang
The response speed and flow regulation performance of water-based directional valves are critical to the positioning accuracy and operational safety of hydraulic supports. However, existing proportional valves struggle to meet the requirements for precise control under high-pressure, high-flow conditions. A novel water-based proportional directional valve with three pilot valves is proposed, together with a dual-loop control strategy consisting of an inner displacement loop and an outer flow loop. The dynamics response characteristics of the valve are investigated through theoretical analysis and model-based simulations, and the dominant structural parameters governing the adjustment time, load disturbance recovery time, and overshoot are identified. A multi-objective optimization is subsequently performed to determine the optimal combination of structural parameters. After optimization, the adjustment time, load disturbance recovery time, and overshoot are reduced by 21%, 25%, and 28%, respectively. A prototype valve was fabricated and a test rig was established for experimental validation. The measured dynamic response was in good agreement with the simulation results, confirming the accuracy of the simulation model and the optimization design method. Under rated operating conditions, the measured spool displacement hysteresis was 3%, while the flow error under dual-loop control was approximately 9%. The findings of the study provide guidance for the structural design and performance optimization of proportional directional valves used in hydraulic support systems.