In vitro propagation can be explored to overcome the constraint of limited planting material in plum. Although it ensures the production of plants in large number, but there are chances of somaclonal variations using this technology. Thus, clonal fidelity of in vitro raised plants should be checked to obtain true to type planting material prior to transplantation in the field. Genetic fidelity of in vitro cultures of plum (Prunus salicina) cvs. Santa Rosa and Frontier multiplied for 5 years (60 passages) through enhanced axillary bud proliferation was tested and compared with 2 year old in vitro raised and mother plants of respective cultivars using RAPD, ISSR and SCoT markers. Out of twenty-eight RAPD primers, eighteen produced 29 and 27 distinct bands in Santa Rosa and Frontier whereas, all of the fifteen ISSR primers screened generated clear reproducible bands in both the cultivars. In SCoT assay, eight primers out of twenty-six generated reproducible bands in both the cultivars. Homogenous amplification was observed in all the samples thereby confirming the genetic fidelity of tissue culture raised plants, thus suggesting that in vitro propagation using axillary buds is the safest mode for the production of clonal planting material in plum.
27 August 2020 in Plant Cell, Tissue and Organ Culture (PCTOC)
The nanoparticles (NPs) of hemoglobin (Hb) were prepared by desolvation method and characterized by transmission electron microscopy (TEM), UV spectroscopy and Fourier-transform IR (FTIR) spectroscopy. An amperometric H2O2 biosensor was constructed by immobilizing HbNPs covalently on to a polycrystalline Au electrode (AuE). HbNPs/AuE were characterized by scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectra (EIS) before and after immobilization of HbNPs. The HbNPs/AuE showed optimum response within 2.5 s at pH 6.5 in 0.1 M sodium phosphate buffer (PB) containing 100 μM H2O2 at 30°C, when operated at –0.2 V against Ag/AgCl. The HbNPs/AuE exhibited Vmax of 5.161 ± 0.1 μA cm−2 with apparent Michaelis-Menten constant (Km) of 0.1 ± 0.01 mM. The biosensor showed lower detection limit (1.0 μM), high sensitivity (129 ± 0.25 μA cm−2 mM−1) and wider linear range (1.0–1200 μM) for H2O2 as compared with earlier biosensors. The analytical recoveries of added H2O2 in serum (0.5 and 1.0 μM) were 97.77 and 98.01% respectively, within and between batch coefficients of variation (CV) were 3.16 and 3.36% respectively. There was a good correlation between sera H2O2 values obtained by standard enzymic colorimetric method and the present biosensor (correlation coefficient, R2 =0.99). The biosensor measured H2O2 level in sera of apparently healthy subjects and persons suffering from diabetes type II. The HbNPs/AuE lost 10% of its initial activity after 90 days of regular use, when stored dry at 4°C.