Jermiah Joseph

Dr. Jermiah Joseph

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
THTimothy John Hunter
Timothy John Hunter
JJJermiah Joseph
Jermiah Joseph
UAUdunna Anazodo
Udunna Anazodo
Sanjay KharcheSanjay Kharche
Sanjay Kharche
CMChristopher McIntyre
Christopher McIntyre
DGDaniel Goldman
Daniel Goldman
Background: Atrial fibrillation is a prevalent cardiac arrhythmia and may reduce cerebral blood perfusion augmenting the risk of dementia. We hypothesize that geometric variations in the cerebral arterial structure called the Circle of Willis (CoW) play an important role in influencing cerebral perfusion. The objective of this work was to develop a novel cardio-cerebral lumped parameter hemodynamic model to investigate the role of CoW variants on cerebral blood flow dynamics under atrial fibrillation conditions. Methods: A computational blood flow model was developed by coupling whole-body and detailed cerebral circulation descriptions, modified to represent six common variations of the CoW. Cerebral blood flow dynamics were simulated in common CoW variants, under control and imposed atrial fibrillation conditions. Risk was assessed based on the frequency of beat-wise hypoperfusion events, and sensitivity analysis was performed with respect to this model output. Results: It was found that the geometry of the CoW influenced the frequency of hypoperfusion events at different heart rates, with the variant missing a P1 segment having the highest risk. Sensitivity analysis revealed that intrinsic heart rate is most associated with the considered outcome. Conclusions: Our results suggest that CoW geometry plays an important role in influencing cerebral hemodynamics during atrial fibrillation. The presented study may assist in guiding our future clinical-imaging research.

29 December 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JJJermiah Joseph
Jermiah Joseph
THTimothy John Hunter
Timothy John Hunter
CSClara Sun
Clara Sun
DGDaniel Goldman
Daniel Goldman
Sanjay KharcheSanjay Kharche
Sanjay Kharche
CMChristopher McIntyre
Christopher McIntyre
Background: We developed a hemodynamic mathematical model of human circulation coupled to a virtual hemodialyzer. The model was used to explore mechanisms underlying our clinical observations involving hemodialysis. Methods: The model consists of whole body human circulation, baroreflex feedback control, and a hemodialyzer. Four model populations encompassing baseline, dialysed, therapeutic hypothermia treated, and simultaneous dialysed with hypothermia were generated. In all populations atrial fibrillation and renal failure as co-morbidities, and exercise as a treatment were simulated. Clinically relevant measurables were used to quantify the effects of each in silico experiment. Sensitivity analysis was used to uncover the most relevant parameters. Results: Relative to baseline, the modelled dialysis increased the population mean diastolic blood pressure by 5%, large vessel wall shear stress by 6%, and heart rate by 20%. Therapeutic hypothermia increased systolic blood pressure by 3%, reduced large vessel shear stress by 15%, and did not affect heart rate. Therapeutic hypothermia reduced wall shear stress by 15% in the aorta and 6% in the kidneys, suggesting a potential anti-inflammatory benefit. Therapeutic hypothermia reduced cardiac output under atrial fibrillation by 12% and under renal failure by 20%. Therapeutic hypothermia and exercise did not affect dialyser function, but increased water removal by approximately 40%. Conclusions: This study illuminates some mechanisms of the action of therapeutic hypothermia. It also suggests clinical measurables that may be used as surrogates to diagnose underlying diseases such as atrial fibrillation.

12 February 2021 in bioRxiv
Verified
Preprint
Open access
PDF file
JJJermiah Joseph
Jermiah Joseph
THTimothy John Hunter
Timothy John Hunter
CSClara Sun
Clara Sun
DGDaniel Goldman
Daniel Goldman
Sanjay KharcheSanjay Kharche
Sanjay Kharche
CMChristopher W. McIntyre
Christopher W. McIntyre
Background The human blood circulation is an intricate process regulated by multiple biophysical factors. Our patients often suffer from renal disease and atrial fibrillation, and are given treatments such as therapeutic hypothermia, exercise, and hemodialysis. In this work, a hemodynamic mathematical model of human circulation coupled to a representative dialysis machine is developed and used to explore causal mechanisms of our recent clinical observations. Methods An ordinary differential equation model consisting of human whole body circulation, baroreflex control, and a hemodialysis machine was implemented. Experimentally informed parameter alterations were used to implement hemodialysis and therapeutic hypothermia. By means of parameter perturbation, four model populations encompassing baseline, dialysed, hypothermia treated, and simultaneous dialysed with hypothermia were generated. In model populations, multiple conditions including atrial fibrillation, exercise, and renal failure were simulated. The effects of all conditions on clinically relevant non-invasive measurables such as heart rate and blood pressure were quantified. A parameter sensitivity analysis was implemented to rank model output influencing parameters in the presented model. Results Results were interpreted as alterations of the respective populations mean values and standard deviations of the clinical measurables, both in relation to the baseline population. A clinical measurable’s smaller standard deviation (in comparison to baseline population) was interpreted as a stronger association between a given clinical measure and the corresponding underlying process, which may permit the use of deducing one by observation of the other. The modelled dialysis was observed to increase systolic blood pressure, vessel shear, and heart rate. Therapeutic hypothermia was observed to reduce blood pressure as well as the intra-population standard deviation (heterogeneity) of blood flow in the large (aorta) and small (kidney) vasculature. Therapeutic hypothermia reduced shear in vessels, suggesting a potential benefit with respect to endothelial dysfunction and maintenance of microcirculatory blood flow. The action of therapeutic hypothermia under conditions such as atrial fibrillation, exercise, and renal failure was to reduce total blood flow, which was applicable in all simulated populations. Therapeutic hypothermia did not affect the dialysis function, but exercise improved the efficacy of dialysis by facilitating water removal. Conclusions This study illuminates some mechanisms of action for therapeutic hypothermia. It also suggests clinical measurables that may be used as surrogates to diagnose underlying diseases such as atrial fibrillation.

23 April 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JJJermiah Joseph
Jermiah Joseph
CSClara Sun
Clara Sun
TLTing-Yim Lee
Ting-Yim Lee
DGDaniel Goldman
Daniel Goldman
Sanjay KharcheSanjay Kharche
Sanjay Kharche
CMChristopher McIntyre
Christopher McIntyre
Background. The treatment of coronary stenosis is decided by performing high risk invasive surgery to generate the fractional flow reserve diagnostics index, a ratio of distal to proximal pressures in respect of coronary atherosclerotic plaques. Non-invasive methods are a need of the times that necessitate the use of mathematical models of coronary hemodynamic physiology. This study proposes an extensible mathematical description of the coronary vasculature that provides an estimate of coronary fractional flow reserve. Methods. By adapting an existing computational model of human coronary blood flow, the effects of large vessel stenosis and microvascular disease on fractional flow reserve were quantified. Several simulations generated flow and pressure information, which was used to compute fractional flow reserve under several conditions including focal stenosis, diffuse stenosis, and microvascular disease. Sensitivity analysis was used to uncover the influence of model parameters on fractional flow reserve. The model was simulated as coupled non-linear ordinary differential equations and numerically solved using our implicit higher order method. Results. Large vessel stenosis affected fractional flow reserve. The model predicts that the presence, rather than severity, of microvascular disease affects coronary flow deleteriously. Conclusions. The model provides a computationally inexpensive instrument for future in silico coronary blood flow investigations as well as clinical-imaging decision making. A combination of focal and diffuse stenosis appears to be essential to limit coronary flow. In addition to pressure measurements in the large epicardial vessels, diagnosis of microvascular disease is essential. The independence of the index with respect to heart rate suggests that computationally inexpensive steady state simulations may provide sufficient information to reliably compute the index.

2 March 2022 in Preprints.org
Verified
Preprint
Open access
PDF file
JJJermiah Joseph
Jermiah Joseph
CSClara Sun
Clara Sun
TLTing-Yim Lee
Ting-Yim Lee
DGDaniel Goldman
Daniel Goldman
Sanjay KharcheSanjay Kharche
Sanjay Kharche
CMChristopher McIntyre
Christopher McIntyre
Background. The treatment of coronary stenosis relies on invasive high risk surgical assessment to generate the fractional flow reserve diagnostics index, a ratio of distal to proximal pressures in respect of coronary atherosclerotic plaque causing stenosis. Non-invasive methods are therefore a need of the times. This study proposes an extensible mathematical description of the coronary vasculature that permits rapid estimation of the coronary fractional flow reserve. Methods. By adapting an existing closed loop model of human coronary blood flow, the effects of large vessel stenosis and microvascular disease on fractional flow reserve were quantified. Several simula-tions generated flow and pressure information which was used to compute fractional flow re-serve under a spectrum of conditions including focal stenosis, diffuse stenosis, and microvascular disease. Sensitivity analysis stratified the influence of model parameters on the index. The model was simulated as coupled non-linear ordinary differential equations and numerically solved us-ing an implicit higher order method. Results. Large vessel stenosis affected fractional flow re-serve. The model predicts that the presence, rather than severity, of microvascular disease affect coronary flow deleteriously. Sensitivity analysis revealed that heart rate may not affect the index. Conclusions. The model provides a computationally inexpensive instrument for future in silico coronary blood flow investigations as well as clinical-imaging decision making. A combination of focal and diffuse stenosis appears to be essential in reducing the index. In addition to pressure measurements in the large epicardial vessels, diagnosis of microvascular disease is essential. The independence of the index with respect to heart rate suggests that computationally inexpensive steady state simulations may provide sufficient information to reliably compute the index.

18 June 2021
Verified
Book Chapter
Closed access
PDF file
JJJermiah Joseph
Jermiah Joseph
TLTing-Yim Lee
Ting-Yim Lee
DGDaniel Goldman
Daniel Goldman
CMChristopher W. McIntyre
Christopher W. McIntyre
Sanjay KharcheSanjay Kharche
Sanjay Kharche