In the context of drug eluting stent, we present two-dimensional numerical models of mass transport of the drug in the wall and in the lumen to study the effect of the drug diffusion coefficients in the three principal media (blood, vascular wall, and polymer coating treated as a three-compartment problem) and the impact of different strut apposition configurations (fully embedded, half embedded, and not embedded). The different conditions were analyzed in terms of their consequence on the drug concentration distribution in the arterial wall. We apply the concept of the therapeutic window to the targeted vascular wall region and derive simple metrics to assess the efficiency of the various stent configurations. Although most of the drug is dispersed in the lumen, variations in the blood flow rate within the physiological range of coronary blood flow and the diffusivity of the drug molecule in the blood were shown to have a negligible effect on the amount of drug in the wall. Our results reveal that the amount of drug cumulated in the wall depends essentially on the relative values of the diffusion coefficients in the polymer coating and in the wall. Concerning the strut apposition, it is shown that the fully embedded strut configuration would provide a better concentration distribution.
Background: In-stent restenosis rates have been closely linked to the wall shear stress distribution within a stented arterial segment, which in turn is a function of stent design. Unfortunately, evaluation of hemodynamic performance can only be evaluated with long term clinical trials. In this work we introduce a set of metrics, based on statistical moments, that can be used to evaluate the hemodynamic performance of a stent in a standardized way. They are presented in the context of a 2D flow study, which analyzes the impact of different strut profiles on the wall shear stress distribution for stented coronary arteries. Results: It was shown that the proposed metrics have the ability to evaluate hemodynamic performance quantitatively and compare it to a common standard. In the context of the simulations presented here, they show that stent's strut profile significantly affect the shear stress distribution along the arterial wall. They also demonstrates that more streamlined profiles exhibit better hemodynamic performance than the standard square and circular profiles. The proposed metrics can be used to compare results from different research groups, and provide an improved method of quantifying hemodynamic performance in comparison to traditional techniques. Conclusion: The strut shape found in the latest generations of stents are commonly dictated by manufacturing limitations. This research shows, however, that strut design can play a fundamental role in the improvement of the hemodynamic performance of stents. Present results show that up to 96% of the area between struts is exposed to wall shear stress levels above the critical value for the onset of restenosis when a tear-drop strut profile is used, while the analogous value for a square profile is 19.4%. The conclusions drawn from the non-dimensional metrics introduced in this work show good agreement with an ordinary analysis of the wall shear stress distribution based on the overall area exposed to critically low wall shear stress levels. The proposed metrics are able to predict, as expected, that more streamlined profiles perform better hemodynamically. These metrics integrate the entire morphology of the shear stress distribution and as a result are more robust than the traditional approach, which only compares the relative value of the local wall shear stress with a critical value of 0.5 Pa. In the future, these metrics could be employed to compare, in a standardized way, the hemodynamic performance of different stent designs.
1 February 2015 in Computers in Biology and Medicine
Grafts used in aortic valve-sparing procedures should ideally not only reproduce the geometry of the natural aortic root but also its material properties. Indeed, a number of studies using the finite element method have shown the importance of the natural sinus shape of the root in the functioning of the normal aortic valve, and the relative increase in stresses due to the replacement of the valve by a stiffer synthetic graft. Because of the wide range in experimentally measured values of aortic wall and leaflet material properties, studies by different research groups have incorporated very different material properties in their models. The aim of the present study was to investigate the influence of material properties on aortic wall displacements, and to determine which material properties would most closely match reported experimental data. Two geometrically accurate 3D models corresponding to the closed and open valve configurations were created in Pro/Engineer CAD software. Loads corresponding to systolic and diastolic pressures were specified and large-displacement structural analyses were carried out using the ANSYS package. Results have indicated that the closest match to experiments using isotropic material properties occurred for a Young's modulus of about 2000 KPa. Nonlinear models based on experimental stress – strain curves have shown similar displacements, but altered strain distribution patterns and significantly lower stresses. These results suggest that an accurate comparison of potential new graft models would have to be made with natural aortic valve models incorporating nonlinear material behavior.