Rosaire Mongrain

Dr. Rosaire Mongrain


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2007 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
RMRosaire Mongrain
Rosaire Mongrain
IFIsam Faik
Isam Faik
RLRichard L. Leask
Richard L. Leask
JRJosep Rodés-Cabau
Josep Rodés-Cabau
ÉLÉric Larose
Éric Larose
OBOlivier F. Bertrand
Olivier F. Bertrand
In the context of drug eluting stent, we present two-dimensional numerical models of mass transport of the drug in the wall and in the lumen to study the effect of the drug diffusion coefficients in the three principal media (blood, vascular wall, and polymer coating treated as a three-compartment problem) and the impact of different strut apposition configurations (fully embedded, half embedded, and not embedded). The different conditions were analyzed in terms of their consequence on the drug concentration distribution in the arterial wall. We apply the concept of the therapeutic window to the targeted vascular wall region and derive simple metrics to assess the efficiency of the various stent configurations. Although most of the drug is dispersed in the lumen, variations in the blood flow rate within the physiological range of coronary blood flow and the diffusivity of the drug molecule in the blood were shown to have a negligible effect on the amount of drug in the wall. Our results reveal that the amount of drug cumulated in the wall depends essentially on the relative values of the diffusion coefficients in the polymer coating and in the wall. Concerning the strut apposition, it is shown that the fully embedded strut configuration would provide a better concentration distribution.

30 April 2009 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
JMJuan Mejia
Juan Mejia
BRBilal Ruzzeh
Bilal Ruzzeh
RMRosaire Mongrain
Rosaire Mongrain
RLRichard Leask
Richard Leask
OBOlivier F Bertrand
Olivier F Bertrand
Background: In-stent restenosis rates have been closely linked to the wall shear stress distribution within a stented arterial segment, which in turn is a function of stent design. Unfortunately, evaluation of hemodynamic performance can only be evaluated with long term clinical trials. In this work we introduce a set of metrics, based on statistical moments, that can be used to evaluate the hemodynamic performance of a stent in a standardized way. They are presented in the context of a 2D flow study, which analyzes the impact of different strut profiles on the wall shear stress distribution for stented coronary arteries. Results: It was shown that the proposed metrics have the ability to evaluate hemodynamic performance quantitatively and compare it to a common standard. In the context of the simulations presented here, they show that stent's strut profile significantly affect the shear stress distribution along the arterial wall. They also demonstrates that more streamlined profiles exhibit better hemodynamic performance than the standard square and circular profiles. The proposed metrics can be used to compare results from different research groups, and provide an improved method of quantifying hemodynamic performance in comparison to traditional techniques. Conclusion: The strut shape found in the latest generations of stents are commonly dictated by manufacturing limitations. This research shows, however, that strut design can play a fundamental role in the improvement of the hemodynamic performance of stents. Present results show that up to 96% of the area between struts is exposed to wall shear stress levels above the critical value for the onset of restenosis when a tear-drop strut profile is used, while the analogous value for a square profile is 19.4%. The conclusions drawn from the non-dimensional metrics introduced in this work show good agreement with an ordinary analysis of the wall shear stress distribution based on the overall area exposed to critically low wall shear stress levels. The proposed metrics are able to predict, as expected, that more streamlined profiles perform better hemodynamically. These metrics integrate the entire morphology of the shear stress distribution and as a result are more robust than the traditional approach, which only compares the relative value of the local wall shear stress with a critical value of 0.5 Pa. In the future, these metrics could be employed to compare, in a standardized way, the hemodynamic performance of different stent designs.

1 February 2015 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
JFJennifer Frattolin
Jennifer Frattolin
MZMarjan Molavi Zarandi
Marjan Molavi Zarandi
CPCatherine Pagiatakis
Catherine Pagiatakis
OBOlivier F. Bertrand
Olivier F. Bertrand
RMRosaire Mongrain
Rosaire Mongrain

1 December 2016 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
NSNastaran Shahmansouri
Nastaran Shahmansouri
MAMohammed Alreshidan
Mohammed Alreshidan
AEAlexander Emmott
Alexander Emmott
KLKevin Lachapelle
Kevin Lachapelle
RCRaymond Cartier
Raymond Cartier
RMRosaire Mongrain
Rosaire Mongrain

1 November 2019 in Acta Biomaterialia
Verified
Journal Article
Closed access
JFJennifer Frattolin
Jennifer Frattolin
RRRanjan Roy
Ranjan Roy
SRSriraman Rajagopalan
Sriraman Rajagopalan
MWMichael T Walsh
Michael T Walsh
SYStephen Yue
Stephen Yue
RMRosaire Mongrain
Rosaire Mongrain

1 January 2004 in Journal of Medical Engineering & Technology
Verified
Journal Article
Closed access
ARA Ranga
A Ranga
RMRosaire Mongrain
Rosaire Mongrain
RGR Mendes Galaz
R Mendes Galaz
YBY Biadillah
Y Biadillah
RCR Cartier
R Cartier
Grafts used in aortic valve-sparing procedures should ideally not only reproduce the geometry of the natural aortic root but also its material properties. Indeed, a number of studies using the finite element method have shown the importance of the natural sinus shape of the root in the functioning of the normal aortic valve, and the relative increase in stresses due to the replacement of the valve by a stiffer synthetic graft. Because of the wide range in experimentally measured values of aortic wall and leaflet material properties, studies by different research groups have incorporated very different material properties in their models. The aim of the present study was to investigate the influence of material properties on aortic wall displacements, and to determine which material properties would most closely match reported experimental data. Two geometrically accurate 3D models corresponding to the closed and open valve configurations were created in Pro/Engineer CAD software. Loads corresponding to systolic and diastolic pressures were specified and large-displacement structural analyses were carried out using the ANSYS package. Results have indicated that the closest match to experiments using isotropic material properties occurred for a Young's modulus of about 2000 KPa. Nonlinear models based on experimental stress – strain curves have shown similar displacements, but altered strain distribution patterns and significantly lower stresses. These results suggest that an accurate comparison of potential new graft models would have to be made with natural aortic valve models incorporating nonlinear material behavior.