D.C. Meena

Prof. D.C. Meena

Delhi Technological University, Delhi, India
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 February 2022 in Energies
Verified
Journal Article
Open access
PDF file
PPPrem Prakash
Prem Prakash
DMD.C. Meena
D.C. Meena
HMHasmat Malik
Hasmat Malik
MAMajed Alotaibi
Majed Alotaibi
Irfan KhanIrfan Khan
Irfan Khan
The present research article focuses on an analytically based method for the optimal allocation and sizing of a renewable energy source (RES) capable of injecting both active and reactive powers in the distribution network. The placement of distributed generation (DG) in the distribution network reduces the magnitude of branch current in between the reference bus and the bus where DG is to be installed. Due to this, system power loss decreases significantly. The proposed method considers different levels of load in addition to peak load demand. The goal of the developed method is to minimize system losses by optimal DG allocations. In the proposed method, the optimum size of the DG is obtained on the basis of maximum loss saving criterion. For the execution of proposed method, only a base case load flow solution is required. The developed method has been tested on IEEE 69-bus and 33-bus radial distribution networks. On the basis of obtained results, it has been realized that the developed method is more capable of diminishing system energy losses.

1 November 2016
Verified
Conference Paper
Closed access
AYAmit Kumar Yadav
Amit Kumar Yadav
MSMadhusudan Singh
Madhusudan Singh
DMD.C. Meena
D.C. Meena
Global warming and increasing oil prices has led the world to discover new energy resources which are environment friendly and are found in abundance so that they meet energy demand of the world. Wind energy is one of the most promising forms of renewable source of energy which can be used to generate electrical energy. In wind technology, a wind turbine is used to convert the kinetic energy of the wind into mechanical energy. Wind turbines are connected to generators with or without a gearbox to produce electricity. A generator is used to convert the mechanical energy coming out of turbine rotor into electrical energy and this energy can be used in standalone systems or with systems connected to the grid. This complete system wind turbine to grid is known as wind energy conversion system (WECS). Wind turbines are large in size and are mounted on a tower at a fixed height hence field study of wind turbines is not easy and physically taxing. Moreover, wind is intermittent in nature and changes continuously with time. Hence the study of wind turbine and its performance analysis under different conditions of wind speed and pitch angle is done by creating a turbine model, which is realised through a dc motor giving the characteristics similar to a turbine. Such a configuration is referred to as wind turbine emulator. In this paper, wind turbine emulator is designed using a separately excited direct current motor operating with a chopper circuit controlled to achieve prescribed wind turbine behaviour through current control of dc motor with a proportional integral (PI) controller. This wind turbine emulator is coupled to permanent magnet synchronous generator (PMSG) to check its performance.

9 December 2021 in Mathematics
Verified
Journal Article
Open access
PDF file
PPPrem Prakash
Prem Prakash
DMD.C. Meena
D.C. Meena
HMHasmat Malik
Hasmat Malik
MAMajed Alotaibi
Majed Alotaibi
Irfan KhanIrfan Khan
Irfan Khan
The objective of the present paper is to study the optimum installation of Non-dispatchable Distributed Generations (NDG) in the distribution network of given sizes under the given scheme. The uncertainty of various random (uncertain) parameters like load, wind and solar operated DG besides uncertainty of fuel prices has been investigated by the three-point estimate method (3-PEM) and Monte Carlo Simulation (MCS) based methods. Nearly twenty percent of the total number of buses are selected as candidate buses for NDG placement on the basis of system voltage profile to limit the search space. Weibull probability density function (PDF) is considered to address uncertain characteristics of solar radiation and wind speed under different scenarios. Load uncertainty is described by Standard Normal Distribution Function (SNDF). To investigate the solution of optimal probabilistic load flow (OPLF) three-point PEM-based technique was applied. For optimization, Genetic Algorithm (GA), Particle Swarm Optimization (PSO) and GA-PSO hybrid-based Artificial Intelligent (AI) based optimization techniques are employed to achieve the optimum value of the multi-objectives function. The proposed multi-objective function comprises loss and different costs. The proposed methods have been applied to IEEE 33- bus radial distribution network. Simulation results obtained by these techniques are compared based on loss minimization capability, enhancement of system bus voltage profile and reduction of cost and fitness functions. The major findings of the present study are the PEM-based method which provides almost similar results as MCS based method with less computation time and as far as loss minimization capacity, voltage profile improvement etc. is concerned, the hybrid-based optimization methods are compared with GA and PSO based optimization techniques.

22 June 2021 in International Journal of Emerging Electric Power Systems
Verified
Journal Article
Closed access
PPPrem Prakash
Prem Prakash
DMD.C. Meena
D.C. Meena
In this paper optimal location and sizing of Non-dispatchable Distributed Generation (NDG) based distributed generation (DG) is investigated by considering uncertainty of NDG. In present study a solar photovoltaic (SPV) is considered as NDG because SPV based DG has uncertain nature of generated power because it is powered by solar irradiance which has uncertain characteristics. To investigate the uncertainty of intermittent nature of solar irradiance Beta Probability Density Function (BPDF) based PDF is considered for addressing the uncertainty of solar insolation. For determining the optimal size of DG unit an analytical based methodology is developed. In this study optimal capacity of NDG is estimated by deriving the expressions of DG unit at each bus. Further, a multi-objective index factor ( MIF ) is designed in order to find out the candidate bus for DG placement. The proposed technique is applied on IEEE 33-bus distribution network. The obtained results reveal that proposed technique provide almost similar result to that of other method which is available in literature.