Fang Zhijian

Dr. Fang Zhijian


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2022 in Environmental Science and Pollution Research
Verified
Journal Article
Closed access
PDF file
IAIbrahim Al-wesabi
Ibrahim Al-wesabi
FZFang Zhijian
Fang Zhijian
CBChukwunonso Philip Bosah
Chukwunonso Philip Bosah
HDHanlin Dong
Hanlin Dong

29 March 2022 in Energies
Verified
Journal Article
Open access
PDF file
IAIbrahim Al-wesabi
Ibrahim Al-wesabi
FZFang Zhijian
Fang Zhijian
Hassan M. Hussein FarhHassan M. Hussein Farh
Hassan M. Hussein Farh
AAAbdullrahman Al-Shamma’a
Abdullrahman Al-Shamma’a
AAAbdullah Al-Shaalan
Abdullah Al-Shaalan
Min DingMin Ding
Min Ding
In the case of partial shading conditions (PSCs), normal equations cannot be completely implemented. The mathematical model of the Photovoltaic (PV) array needs to be modified and re-established with the existence of bypass diodes connected to the PV module, which can alleviate the negative effects of the PSCs and generate several peaks on the PV output characteristics curve. The first aim of this study is to modify and re-establish the mathematical model of the PV array under PSCs. Second, it aims to improve and validate the reliable Cuckoo Search Algorithm (CSA) by integrating it with PID (hybrid CSA-PID) to diminish the impact of PSCs problems. The hybrid CSA-PID was proposed to both track the global maximum power point (GMPP) of PV systems and reduce the tracking time to eliminate the fluctuations around the GMPP. Further, the PID controller was used to eliminate the error percentage obtained by CSA under PSCs to generate the required duty cycle, which provides the required and desired maximum voltage accordingly. The proposed CSA-PID technique has been implemented using both Matlab/Simulink and Hardware-In-Loop experiments on the MT real-time control platform NI PXIE-1071. For validation, the Hybrid CSA-PID method is evaluated and compared with CSA, modified particle swarm optimization (MPSO), PSO, and modified perturb and observe (MP&O) methods under similar conditions. Finally, the obtained findings demonstrated the efficacy and superiority of the proposed hybrid CSA-PID technique, demonstrating its resilience, fast reaction, and good performance in terms of tracking time and GMPP tracking.

19 November 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
IAIbrahim Al-Wesabi
Ibrahim Al-Wesabi
FZFang Zhijian
Fang Zhijian
Hassan M. Hussein FarhHassan M. Hussein Farh
Hassan M. Hussein Farh
AAAbdullrahman A. Al-Shamma’a
Abdullrahman A. Al-Shamma’a
HDHanlin Dong
Hanlin Dong
TKTarek Kandil
Tarek Kandil
Low ripples and variations in the DC-Bus voltage in single-phase Photovoltaic/Battery Energy Storage (PV/BES) grid-connected systems may cause significant harmonics distortion, instability, and reduction in power factor. The use of short-life electrolytic capacitor on the DC-Bus is considered a standard way for reducing these ripples and variations because of its large capacitance but results in short lifetime of the inverter. Replacing large electrolytic capacitors with small film capacitors can extend the lifetime of a PV/BES grid-connected system because small film capacitors have longer lifetime than large electrolytic capacitors. These film capacitors have low capacitance, which causes severe oscillations in the output current, and voltage drop due to huge ripples on the DC-Bus voltage. In this research, the main goal is to eliminate the output current ripples and voltage fluctuations associated with employing film capacitors. First, a modified incremental conductance (MIC) technique is proposed for tracking the maximum power by controlling the duty ratio of the DC-DC boost converter. Second, for the first time, a simple and novel d-q current regulation technique, which employs flowchart decision logic, is used in the DC-Bus control system for both the PV power system and the state of charge (SOC) of the BES. In this case, the DC-Bus controller is characterized by a cost-effective implementation because of its low sampling frequency. Although the presented approaches are successful in eliminating voltage distortion and fluctuations, they have unacceptable dynamic performance. Therefore, to improve the dynamic performance, BES was used to maintain a reliable and stable harvest from PV modules for varying loads while also increasing the dynamic performance of the overall system. The proposed PV/BES grid-connected systems, which employs a small 10-µF bus capacitor, is simulated and connected to the grid (230 V, 50 Hz). The DC-Bus voltage overshoot, undershoot and the total harmonics distortion (THD) of the output current for the proposed MIC are (1 V), (2.5 V) and (less than 5%), respectively. The average time response under rising radiation to track the global peak for MIC, traditional incremental conductance and variable step size incremental conductance are 1.403 s, 1.501 s and 1.113 s respectively. The obtained findings demonstrated the efficacy and superiority of the proposed d-q current control and MIC technique.

1 January 2022 in Electronics
Verified
Journal Article
Open access
PDF file
IAIbrahim Al-wesabi
Ibrahim Al-wesabi
FZFang Zhijian
Fang Zhijian
ZWZhiguo Wei
Zhiguo Wei
HDhanlin dong
hanlin dong
Large electrolytic capacitors used in grid-connected and stand-alone photovoltaic (PV) applications for power decoupling purposes are unreliable because of their short lifetime. Film capacitors can be used instead of electrolytic capacitors if the energy storage requirement of the power conditioning units (PCUs) is reduced, since they offer better reliability and have a longer lifetime. Film capacitors have a lower capacitance than electrolytic capacitors, causing enormous frequency ripples on the DC-link voltage and affecting the standalone photovoltaic system’s dynamic performance. This research provided novel direct sliding mode controllers (DSMCs) for minimizing DC-link capacitor, regulating various components of the PV/BES system that assists to manage the DC-link voltage with a small capacitor. DSMCs were combined with the perturb and observe (P&O) method for DC boost converters to increase the photovoltaic system’s dynamic performance, and regulate the battery’s bidirectional converter (BDC) to overcome the DC-link voltage instabilities caused via a lower DC-link capacitor. The system is intended to power both AC and DC loads in places without grid connection. The system’s functions are divided into four modes, dependent on energy supply and demand, and the battery’s state of charge. The findings illustrate the controllers’ durability and the system’s outstanding performance. The testing was carried out on the MT real-time control platform NI PXIE-1071 utilizing Hardware-In-The-Loop experiments and MATLAB/Simulink.

22 December 2021 in Electronics
Verified
Journal Article
Open access
PDF file
HDhanlin dong
hanlin dong
FZFang Zhijian
Fang Zhijian
IAIbrahim Al-wesabi
Ibrahim Al-wesabi
JCJie Cai
Jie Cai
This research proposes an optimization technique for an integrated energy system that includes an accurate prediction model and various energy storage forms to increase load forecast accuracy and coordinated control of various energies in the current integrated energy system. An artificial neural network is utilized to create an accurate short-term load forecasting model to effectively predict user demand. The 0–1 mixed integer linear programming approach is used to analyze the optimal control strategy for multiple energy systems with storage, cold energy, heat energy, and electricity to solve the problem of optimal coordination. Simultaneously, a precise load forecasting method and an optimal scheduling strategy for multienergy systems are proposed. The equipment scheduling plan of the integrated energy system of gas, heat, cold, and electricity is proposed after researching the operation characteristics and energy use process of the equipment in the combined power supply system. A system economic operation model is created with profit maximization in mind, while also taking into account energy coordination between energy and the power grid. The rationality of the algorithm and model is verified by analyzing the real data of a distributed energy station in Wuhan for two years.

8 December 2017 in Energies
Verified
Journal Article
Open access
PDF file
GHGuozhen Hu
Guozhen Hu
JZJunkun Zhang
Junkun Zhang
JWJunhua Wang
Junhua Wang
FZFang Zhijian
Fang Zhijian
CCCai Changsong
Cai Changsong
ZLZhongzheng Lin
Zhongzheng Lin
A loosely coupled inductive power transfer (IPT) system for industrial track applications has been researched in this paper. The IPT converter using primary Inductor-Capacitor-Inductor (LCL) network and secondary parallel-compensations is analyzed combined coil design for optimal operating efficiency. Accurate mathematical analytical model and expressions of self-inductance and mutual inductance are proposed to achieve coil parameters. Furthermore, the optimization process is performed combined with the proposed resonant compensations and coil parameters. The results are evaluated and discussed using finite element analysis (FEA). Finally, an experimental prototype is constructed to verify the proposed approach and the experimental results show that the optimization can be better applied to industrial track distributed IPT system.