To evaluate the repeatability of corneal biomechanical parameters in normal and keratoconus eyes, and explore factors that affects the repeatability, and further assess the diagnostic ability of new parameters. Seventy-seven keratoconus eyes of 47 patients and 77 right eyes of 77 normal subjects were recruited in current study. All participants received three repeated measurements with 2 to 5 minutes interval. The interclass correlation coefficient (ICC), Cronbach’ α and repeatability coefficient (RC) were evaluated. The liner regression analysis was used to identify factors that affect the repeatability, and linear mixed effects model was performed to compare the parameters differences. The receiver operating characteristic (ROC) curve was used to evaluate the diagnostic ability of new parameters. Eighteen parameters in normal eyes and twenty-two parameters in keratoconus eyes showed excellent repeatability (ICC ≥ 0.90). Age, axial measurement (AL), spherical equivalent, astigmatism, gender, mean keratometry (Kmean), intraocular pressure (IOP) and central corneal thickness (CCT) could affect the repeatability of new Corvis ST parameters. Compared with normal eyes, the Ambrósio’s Relational Thickness horizontal (ARTh), biomechanical corrected IOP (bIOP), stiffness parameter at first applanation (SP A1) were low and the Max Inverse Radius, deformation amplitude (DA) Ratio Max [2 mm], Pachy Slope, DA Ratio Max [1 mm], Integrated Radius and Corvis Biomechanical Index (CBI) were high in keratoconus eyes (All P < 0.05). Both ARTh and CBI had high Youden index (0.870), and the corresponding cut-off values were 379.29 and 0.44. The repeatability of Corvis ST parameters was acceptable both in normal and keratoconus eyes, and new parameters could effectively diagnose keratoconus eyes from normal eyes.

2 March 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SRShengwei Ren
Shengwei Ren
LXLiyan Xu
Liyan Xu
QFQi Fan
Qi Fan
YGYuwei Gu
Yuwei Gu
KYKaili Yang
Kaili Yang
This study aimed to compare the values of new corneal visualization Scheimpflug technology (Corvis ST) parameters in normal, subclinical keratoconus (SKC) and keratoconus (KC) eyes, and evaluate the diagnostic ability to distinguish SKC and KC eyes from normal eyes. One-hundred normal, 100 SKC and 100 KC eyes were included in the study. Corvis ST parameters containing dynamic corneal response parameters were measured by one ophthalmologist. The receiver operating characteristic curve was used to evaluate the diagnostic ability of new Corvis ST parameters. The new Corvis ST parameters in KC eyes were different from those in the control and SKC eyes after adjusting for IOP and CCT, and stiffness parameter at the first applanation (SP-A1) and Corvis biomechanical index (CBI) were significantly different between the control and SKC eyes (all P < 0.05). The parameter with the highest diagnostic efficiency was SP-A1 (Youden index = 0.40, AUC = 0.753), followed by CBI (Youden index = 0.38, AUC = 0.703), and Integrated Radius (Youden index = 0.33, AUC = 0.668) in diagnosing SKC from control eyes. New Corvis ST parameters in SKC eyes were significantly different from normal control and KC eyes, and could be considered to distinguish SKC and KC eyes from normal eyes.

29 September 2022 in Frontiers in Immunology
Verified
Journal Article
Open access
KYKaili Yang
Kaili Yang
DLDan Li
Dan Li
LXLiyan Xu
Liyan Xu
CPChenjiu Pang
Chenjiu Pang
DZDongqing Zhao
Dongqing Zhao
SRShengwei Ren
Shengwei Ren
Purpose: To evaluate the independent and interactive effects of eye rubbing and atopy on keratoconus (KC) in central China.Methods: A total of 330 KC patients and 330 controls were recruited in the case-control study. Eye rubbing and history of atopy were recorded through face-to-face interviews. The association between KC and eye rubbing, atopy, interactive effects of eye rubbing and atopy were analyzed by logistic regression, and the odds ratios (OR), relative excess risk due to interaction (RERI), attributable proportion (AP), synergy (S) index, and 95% confidence intervals (95% CI) were calculated.Results: A total of 228 patients (69.09%) had an eye rubbing history, and 53 (16.06%) had an atopy history in the KC group, which were both higher than that in the control group (p0.05).Conclusion: Eye rubbing and atopy were separately positively associated with KC, and there was a strong impact of coexistent eye rubbing and atopy on KC in China. Further multi-center and cohort study need to be conducted to explore the role of eye rubbing and atopy in the occurrence and development of KC.

30 March 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KYKaili Yang
Kaili Yang
LXLiyan Xu
Liyan Xu
QFQi Fan
Qi Fan
YGYuwei Gu
Yuwei Gu
PSPeng Song
Peng Song
SRShengwei Ren
Shengwei Ren
The aim of this study was to evaluate the distribution of new Corneal Visualisation Scheimpflug Technology (Corvis ST) parameters in normal, Post-laser in situ keratomileusis (LASIK), Post-LASIK keratectasia (KE) and keratoconus (KC) eyes, and explore the diagnostic ability of these parameters in distinguishing KE from LASIK eyes. Twenty-three normal eyes, 23 LASIK eyes, 23 KE eyes and 23 KC eyes were recruited in this study. The following new Corvis ST parameters were measured: Max Inverse Radius, deformation amplitude (DA) Ratio Max [2 mm], Pachy Slope, DA Ratio Max [1 mm], Ambrosio’s relational thickness horizontal (ARTh), Integrated Radius, stiffness parameter at first applanation (SP-A1) and Corvis biomechanical index (CBI). The general linear model, linear regression model, relation analysis and receiver operating characteristic (ROC) curve were performed. The Max Inverse Radius, DA Ratio Max [2 mm], Pachy Slope, DA Ratio Max [1 mm], Integrated Radius and CBI in LASIK eyes, KE eyes and KC eyes were higher than in normal eyes, while the ARTh and SP-A1 parameters were lower than in normal eyes. The KE eyes had higher Max Inverse Radius, DA Ratio Max [2 mm], Pachy Slope, DA Ratio Max [1 mm], Integrated Radius, and lower SP-A1 value than LASIK eyes (all P < 0.05). The central corneal thickness was related to the Pachy Slope (r = −0.485), ARTh (r = −0.766), SP-A1 (r = 0.618) in KE eyes (all P < 0.05). The area under the ROC curve of Integrated Radius, Max Inverse Radius, DA Ratio Max [2 mm] and SP-A1 were above 0.800 in identifying KE from LASIK eyes. Thus, the new Corvis ST parameters were different between LASIK and KE eyes, suggesting that they might be helpful in distinguishing KE eyes from LASIK eyes. However, a further multi-center and large sample study is necessary to confirm these findings.

18 July 2022 in Frontiers in Pediatrics
Verified
Journal Article
Open access
KYKaili Yang
Kaili Yang
YGYuwei Gu
Yuwei Gu
LXLiyan Xu
Liyan Xu
QFQi Fan
Qi Fan
MZMeng Zhu
Meng Zhu
SRShengwei Ren
Shengwei Ren
Purpose: To evaluate the distribution of pediatric keratoconus patients and the disease severity based on different age and gender groups in China.Materials and methods: A total of 446 keratoconus eyes in 266 pediatric patients from January 2019 to January 2022 were included in the cross-sectional study. The clinical findings and severity of keratoconus were recorded and Kruskal–Wallis test, chi-squared test, and Cochran-Mantel-Haenszel (CMH) test were used to compare the parameters between different gender and age groups.Results: The male/female ratio was 353/93 (3.8:1), and the median age was 16 years (range: 6–17 years). Male patients were statistically younger than female patients (P = 0.041). The male/female ratio decreased with age (P for trend = 0.011). The distribution of the topographic keratoconus classification (TKC) stage was significantly different between gender and age groups (all P < 0.05). Male patients had a higher ratio of advanced keratoconus eyes (TKC ≥ 3) than female patients (P < 0.001), and CMH analysis indicated that being a male was a risk factor for advanced keratoconus after controlling for age (odds ratio: 2.581, P < 0.001).Conclusion: Male keratoconus patients were younger, with a higher ratio of advanced keratoconus than female patients in the Chinese pediatric patients evaluated. Multicenter studies with larger sample sizes are necessary in the future.

6 April 2021 in Scientific Reports
Verified
Journal Article
Open access
PDF file
KYKaili Yang
Kaili Yang
LXLiyan Xu
Liyan Xu
QFQi Fan
Qi Fan
YGYuwei Gu
Yuwei Gu
BZBo Zhang
Bo Zhang
SRShengwei Ren
Shengwei Ren
China is a populous country but lacks epidemiological data on keratoconus (KC). The present study aimed to investigate the clinical data, demographic data, and visual function (VF) data of KC patients in Central China. A total of 524 KC eyes in 307 KC patients (217 bilateral and 90 unilateral) from Henan Eye Hospital were included in the current study. Demographic and VF data were assessed with questionnaires administered by well-trained staff during face-to-face interviews. Visual acuity value was examined by a qualified optometrist, and the clinical data were measured by professional clinicians. The distributions of sex, residence and education level of KC patients were compared by Chi-square tests, and the ratios of people wearing glasses and rigid gas permeable (RGP) lenses were compared by McNemar tests. General linear models/Chi-squared tests were used to compare the clinical and demographic data according to KC severity. Spearman’s correlation analysis was used to test the associations between the data and KC severity. The mean age at diagnosis was 20.98 ± 6.06 years, and males had a higher ratio of KC than females (P < 0.001). Patients in rural areas had a higher rate of KC than those in urban areas (P = 0.039), and the proportion of KC patients with a higher education level (above high school) was high (P < 0.001). A total of 68.40% of the patients reported eye rubbing and 3.52% had a positive family history. The percentage of people wearing glasses was higher than that of patients wearing RGP lenses (P < 0.001). The total VF score of KC patients was 69.35 ± 15.25. The thinnest corneal thickness (TCT) and stiffness parameter at the first applanation (SP-A1) values were inversely correlated with KC severity (P < 0.05). The mean, steep, and max keratometry (Km, Ks and Kmax) values, the RGP lens use and keratoplasty were positively correlated with KC severity (all P < 0.05). The total VF score of the eye with better VA decreased as the severity increased (r = − 0.21, P = 0.002). The present study comprehensively describes various associated features of KC patients from a tertiary hospital in Central China, providing a reference for understanding the characteristics of KC patients in China.