Lin Li

Dr. Lin Li

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2009 in Skeletal Radiology
Verified
Journal Article
Closed access
PDF file
ZZZhen Zhao
Zhen Zhao
LLLin Li
Lin Li
FLFanglan Li
Fanglan Li
LZLixia Zhao
Lixia Zhao

19 May 2020 in Advanced Healthcare Materials
Verified
Journal Article
Closed access
PDF file
FPFuwen Pang
Fuwen Pang
YLYuhao Li
Yuhao Li
WZWenjie Zhang
Wenjie Zhang
CXChunchao Xia
Chunchao Xia
QHQing He
Qing He
LLLin Li
Lin Li

1 May 2011 in Clinical Nuclear Medicine
Verified
Journal Article
Closed access
RHRui Huang
Rui Huang
FLFanglan Bs Li
Fanglan Bs Li
ZZZhen Zhao
Zhen Zhao
BLBin Liu
Bin Liu
XOXiaohong Ou
Xiaohong Ou
LLLin Li
Lin Li
Background: This study aimed to determine whether attenuation correction using the Hybrid SPECT/CT reduced attenuation artifacts. Methods and Results: Ninety-nine patients (55 men and 44 women) underwent coronary angiography and electrocardiography gated stress/rest myocardial perfusion imaging using Tc-99m sestamibi (MIBI) with CT-attenuation correction (CT-AC) for stress scans. Visual semi-quantitative analysis of the CT-AC and noncorrected perfusion images was performed. In this study, there was 39.3% moderate or severe misregistration. The overall specificity, sensitivity, and accuracy for noncorrected versus CT-AC were 62.9% versus 79.0% (P = 0.041), 94.6% versus 91.9% (P = NS), and 74.7% versus 83.8% (P = 0.035), respectively. CT-AC increased specificity in the right coronary artery region, from 77.9% to 98.7% (P = 0.000), accompanied by a decrease in specificity in the left anterior descending region, from 94.1% to 82.4% (P = 0.008). CT-AC significantly reduced defect scores in the inferior wall. This was more obvious in men than in women (P = 0.027). In the anterior wall, although a tendency for defect scores to increase with CT-AC was observed only in men, no significant difference was found between the gender (P = 0.049). Conclusion: Attenuation correction using Hybrid SPECT/CT improved specificity in the right coronary artery, but decreased specificity in the left anterior descending. This technique is likely to be more useful in men than in women.

1 October 2020 in Nanomedicine: Nanotechnology, Biology and Medicine
Verified
Journal Article
Closed access
HZHuijun Zhou
Huijun Zhou
QZQing Zhang
Qing Zhang
YCYan Cheng
Yan Cheng
LXLili Xiang
Lili Xiang
GSGuohua Shen
Guohua Shen
ZCZhen Cheng
Zhen Cheng

5 November 2015 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
HZHuijun Zhou
Huijun Zhou
GSGuohua Shen
Guohua Shen
WZWenjie Zhang
Wenjie Zhang
HCHuawei Cai
Huawei Cai
YZYue Zhou
Yue Zhou
LLLin Li
Lin Li
The aim of this work was to assess the overall value of 18F-FDG PET/CT in the diagnosis of residual or recurrent nasopharyngeal carcinoma using a metaanalysis. Methods: The literature published between January 1990 and September 2014 was searched in the PubMed, EMBASE, Cochrane Library, EBSCO, VIP, CNKI, and Wanfang databases to identify eligible studies on PET/CT of residual or recurrent lesions. The methodologic quality of the included studies was evaluated using the “quality assessment for studies of diagnostic accuracy” tool. Summary sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, diagnostic odds ratio, and receiver-operating characteristic curve were obtained using Meta-DiSc freeware. Subgroups were also analyzed. Results: A total of 23 studies, involving 1,253 subjects, were included in the metaanalysis. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio, with 95% confidence intervals in parentheses, for 18F-FDG PET or PET/CT were 0.93 (0.91–0.95), 0.87 (0.84–0.89), 5.52 (3.96–7.71), 0.12 (0.09–0.15), and 55.31 (34.94–87.57), respectively. The area under the receiver-operating characteristic curve and Q* index estimate of PET/CT were 0.9473 and 0.8869, respectively. There was no significant difference between the area under the curve of PET and PET/CT (P > 0.05). Conclusion: Our study has confirmed that 18F-FDG PET/CT has high sensitivity and specificity but significant heterogeneity in the diagnosis of residual or recurrent nasopharyngeal carcinoma.

9 February 2023 in Biomaterials Research
Verified
Journal Article
Open access
PDF file
LXLiu Xiao
Liu Xiao
YLYuhao Li
Yuhao Li
RGRuiman Geng
Ruiman Geng
LCLihong Chen
Lihong Chen
PYPeng Yang
Peng Yang
HCHuawei Cai
Huawei Cai
Background: Transarterial radioembolization (TARE) with 90 Y-labeled glass and resin microspheres is one of the primary treatment strategies for advanced-stage primary and metastatic hepatocellular carcinoma (HCC). However, difficulties of real-time monitoring post administration and embolic hypoxia influence treatment prognosis. In this study, we developed a new biodegradable polymer microsphere that can simultaneously load 177 Lu and MgO nanoparticle, and evaluated the TARE therapeutic efficacy and biosafety of 177 Lu-PDA-CS-MgO microspheres for HCC treatment. Methods: Chitosan microspheres were synthesized through emulsification crosslink reaction and then conducted surface modification with polydopamine (PDA). The 177 Lu and nano MgO were conjugated to microspheres using active chemical groups of PDA. The characteristics of radionuclide loading efficiency, biodegradability, blood compatibility, and anti-tumor effectwere evaluated both in vitro and in vivo. SPECT/CT imaging was performed to monitor bio-distribution and bio-stability of 177 Lu-PDA-CS-MgO after TARE treatment. The survival duration of each rat was monitored. HE analysis, TUNEL analysis, immunohistochemical analysis, and western blot analysis were conducted to explore the anti-tumor effect and mechanism of composited microspheres. Body weight, liver function, blood routine examination were monitored at different time points to evaluate the bio-safety of microspheres. Results: The composite 177 Lu-PDA-CS-MgO microsphere indicated satisfactory degradability, biocompatibility, radionuclide loading efficiency and radiochemical stability in vitro. Cellular evaluation showed that 177 Lu-PDA-CS-MgO had significant anti-tumor effect and blocked tumor cell cycles in S phase. Surgical TARE treatment with 177 Lu-PDA-CS-MgO significantly prolonged the medial survival time from 49 d to 105 d, and effectively inhibited primary tumor growth and small metastases spreading. Moreover, these microspheres indicated ideal in vivo stability and allowed real-time SPECT/CT monitoring for up to 8 weeks. Immunostaining and immunoblotting results also confirmed that 177 Lu-PDA-CS-MgO had potential in suppressing tumor invasion and angiogenesis, and improved embolic hypoxia in HCC tissues. Further evaluations of body weight, blood test, and pathological analysis indicated good biosafety of 177 Lu-PDA-CS-MgO microspheres in vivo. Conclusion: Our study demonstrated that 177 Lu-PDA-CS-MgO microsphere hold great potential as interventional brachytherapy candidate for HCC therapy. Graphical Polymer composite microspheres loading 177 Lu radionuclide and MgO nanoparticles for interventional radioembolization therapy and real-time SPECT imaging of hepatic cancer.