Young Ha Kim

Young Ha Kim


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Journal of Korean Neurosurgical Society
Verified
Journal Article
Open access
PDF file
JLJun Seok Lee
Jun Seok Lee
DSDong Wuk Son
Dong Wuk Son
SLSu Hun Lee
Su Hun Lee
SSSoonki Sung
Soonki Sung
SLSang Weon Lee
Sang Weon Lee
YKYoung Ha Kim
Young Ha Kim
Objective : The most common complication of anterior cervical discectomy and fusion (ACDF) is cage subsidence and maintenance of disc height affects postoperative clinical outcomes. We considered cage subsidence as an inappropriate indicator for evaluating preservation of disc height. Thus, this study aimed to consider patients with complications such as reduced total disc height compared to that before surgery and evaluate the relevance of several factors before ACDF.Methods : We retrospectively reviewed the medical records of 40 patients who underwent stand-alone single-level ACDF using a polyetheretherketone (PEEK) cage at our institution between January 2012 and December 2018. Our study population comprised 19 male and 21 female patients aged 24–70 years. The minimum follow-up period was 1 year. Twenty-seven patients had preoperative bone mineral density (BMD) data on dual-energy X-ray absorptiometry. Clinical parameters included sex, age, body mass index, smoking history, and prior medical history. Radiologic parameters included the C2-7 cobb angle, segmental angle, sagittal vertical axis, disc height, and total intervertebral height (TIH) at the preoperative and postoperative periods. Cage decrement was defined as the reduction in TIH at the 6-month follow-up compared to preoperative TIH. To evaluate the bone quality, Hounsfield unit (HU) value was calculated in the axial and sagittal images of conventional computed tomography.Results : Lumbar BMD values and cervical HU values were significantly correlated (r=0.733, p<0.001). We divided the patients into two groups based on cage decrement, and 47.5% of the total patients were regarded as cage decrement. There were statistically significant differences in the parameters of measuring the HU value of the vertebra and intraoperative distraction between the two groups. Using these identified factors, we performed a receiver operating characteristic (ROC) curve analysis. Based on the ROC curve, the cut-off point was 530 at the HU value of the upper cortical and cancellous vertebrae (p=0.014; area under the curve [AUC], 0.727; sensitivity, 94.7%; specificity, 42.9%) and 22.41 at intraoperative distraction (p=0.017; AUC, 0.722; sensitivity, 85.7%; specificity, 57.9%). Using this value, we converted these parameters into a bifurcated variable and assessed the multinomial regression analysis to evaluate the risk factors for cage decrement in ACDF. Intraoperative distraction and HU value of the upper vertebral body were independent factors of postoperative subsidence.Conclusion : Insufficient intraoperative distraction and low HU value showed a strong relationship with postoperative intervertebral height reduction following single stand-alone PEEK cage ACDF.

1 November 2021 in Journal of Korean Neurosurgical Society
Verified
Journal Article
Open access
PDF file
CKChang Hyeun Kim
Chang Hyeun Kim
CLChi Hyung Lee
Chi Hyung Lee
YKYoung Ha Kim
Young Ha Kim
SSSoonki Sung
Soonki Sung
DSDong Wuk Son
Dong Wuk Son
GSGeun Sung Song
Geun Sung Song
Objective : Vertebral artery dissecting aneurysm (VADA) is a very rare subtype of intracranial aneurysms; when ruptured, it is associated with significantly high rates of morbidity and mortality. Despite several discussions and debates, the optimal treatment for VADA has not yet been established. In the last 10 years, flow diverter devices (FDD) have emerged as a challenging and new treatment method, and various clinical and radiological results have been reported about their safety and effectiveness. The aim of our study was to evaluate the clinical and radiological results with the use of FDD in the treatment of unruptured VADA.Methods : We retrospectively evaluated the data of all patients with unruptured VADA treated with FDD between January 2018 and February 2021 at our hybrid operating room. Nine patients with unruptured VADA, deemed hemodynamically unstable, were treated with FDD. Among other parameters, the technical feasibility of the procedure, procedure-related complications, angiographic results, and clinical outcomes were evaluated.Results : Successful FDD deployment was achieved in all cases, and the immediate follow-up angiography showed intra-aneurysmal contrast stasis with parent artery preservation. A temporary episode of facial numbness and palsy was noted in one patient; however, the symptoms had completely disappeared when followed up at the outpatient clinic 2 weeks after the procedure. The 3–6 months follow-up angiography (n=9) demonstrated complete/near-complete obliteration of the aneurysm in seven patients, and partial obliteration and segmental occlusion in one patient each. In the patient who achieved only partial obliteration, there was a sac 13 mm in size, and there was no change in the 1-year follow-up angiography. In the patient with segmental occlusion, the cause could not be determined. The clinical outcome was modified Rankin Scale 0 in all patients.Conclusion : Our preliminary study using FDD to treat hemodynamically unstable unruptured VADA showed that FDD is safe and effective. Our study has limitations in that the number of cases is small, and it is not a prospective study. However, we believe that the study contributes to evidence regarding the safety and effectiveness of FDD in the treatment of unruptured VADA.

1 October 2008 in Macromolecular Research
Verified
Journal Article
Closed access
PDF file
HLHanna Lee
Hanna Lee
GTGiyoong Tae
Giyoong Tae
YKYoung Ha Kim
Young Ha Kim

1 November 2003 in Korean Journal of Chemical Engineering
Verified
Journal Article
Closed access
PDF file
YKYong-Wan Kim
Yong-Wan Kim
JKJae-Jin Kim
Jae-Jin Kim
YKYoung Ha Kim
Young Ha Kim

18 January 2021 in Brain Sciences
Verified
Journal Article
Open access
PDF file
YKYoung Ha Kim
Young Ha Kim
CLChi Hyung Lee
Chi Hyung Lee
CKChang Hyeun Kim
Chang Hyeun Kim
DSDong Wuk Son
Dong Wuk Son
SLSang Weon Lee
Sang Weon Lee
SSSoonki Sung
Soonki Sung
(1) Background: Cranioplasty is a surgery to repair a skull bone defect after decompressive craniectomy (DC). If the process of dissection of the epidural adhesion tissue is not performed properly, it can cause many complications. We reviewed the effect of a silicone elastomer sheet designed to prevent adhesion. (2) Methods: We retrospectively reviewed 81 consecutive patients who underwent DC and subsequent cranioplasty at our institution between January 2015 and December 2019. We then divided the patients into two groups, one not using the silicone elastomer sheet (n = 50) and the other using the silicone elastomer sheet (n = 31), and compared the surgical outcomes. (3) Results: We found that the use of the sheet shortened the operation time by 24% and reduced the estimated blood loss (EBL) by 43% compared to the control group. Moreover, the complication rate of epidural fluid collection (EFC) in the group using the sheet was 16.7%, which was lower than that in the control group (41.7%, p < 0.023). Multivariate logistic regression analysis showed the sheet (OR 0.294, 95% CI 0.093–0.934, p = 0.039) to be significantly related to EFC. (4) Conclusions: The technique using the silicone elastomer sheet allows surgeons to easily dissect the surgical plane during cranioplasty, which shortens the operation time, reduces EBL, and minimizes complications of EFC.

1 January 2024 in Journal of Korean Neurosurgical Society
Verified
Journal Article
Open access
PDF file
BOBu Kwang Oh
Bu Kwang Oh
DSDong Wuk Son
Dong Wuk Son
JLJun Seok Lee
Jun Seok Lee
SLSu Hun Lee
Su Hun Lee
YKYoung Ha Kim
Young Ha Kim
Seong-Tae YiSeong-Tae Yi
Seong-Tae Yi
Objective : Recently, robotic-assisted spine surgery (RASS) has been considered a minimally invasive and relatively accurate method. In total, 495 robotic-assisted pedicle screw fixation (RAPSF) procedures were attempted on 100 patients during a 14-month period. The current study aimed to analyze the accuracy, potential risk factors, and learning curve of RAPSF.Methods : This retrospective study evaluated the position of RAPSF using the Gertzbein and Robbins scale (GRS). The accuracy was analyzed using the ratio of the clinically acceptable group (GRS grades A and B), the dissatisfying group (GRS grades C, D, and E), and the Surgical Evaluation Assistant program. The RAPSF was divided into the no-breached group (GRS grade A) and breached group (GRS grades B, C, D, and E), and the potential risk factors of RAPSF were evaluated. The learning curve was analyzed by changes in robot-used time per screw and the occurrence tendency of breached and failed screws according to case accumulation.Results : The clinically acceptable group in RAPSF was 98.12%. In the analysis using the Surgical Evaluation Assistant program, the tip offset was 2.37±1.89 mm, the tail offset was 3.09±1.90 mm, and the angular offset was 3.72°±2.72°. In the analysis of potential risk factors, the difference in screw fixation level (p=0.009) and segmental distance between the tracker and the instrumented level (p=0.001) between the no-breached and breached group were statistically significant, but not for the other factors. The mean difference between the no-breach and breach groups was statistically significant in terms of pedicle width (p<0.001) and tail offset (p=0.042). In the learning curve analysis, the occurrence of breached and failed screws and the robot-used time per screw screws showed a significant decreasing trend.Conclusion : In the current study, RAPSF was highly accurate and the specific potential risk factors were not identified. However, pedicle width was presumed to be related to breached screw. Meanwhile, the robot-used time per screw and the incidence of breached and failed screws decreased with the learning curve.