Aimee Sakes

Dr. Aimee Sakes

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 July 2016 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ASAimee Sakes
Aimee Sakes
MWMarleen van der Wiel
Marleen van der Wiel
PHPaul W. J. Henselmans
Paul W. J. Henselmans
Johan Van LeeuwenJohan Van Leeuwen
Johan Van Leeuwen
DDDimitra Dodou
Dimitra Dodou
PBPaul Breedveld
Paul Breedveld
In nature, shooting mechanisms are used for a variety of purposes, including prey capture, defense, and reproduction. This review offers insight into the working principles of shooting mechanisms in fungi, plants, and animals in the light of the specific functional demands that these mechanisms fulfill. We systematically searched the literature using Scopus and Web of Knowledge to retrieve articles about solid projectiles that either are produced in the body of the organism or belong to the body and undergo a ballistic phase. The shooting mechanisms were categorized based on the energy management prior to and during shooting. Shooting mechanisms were identified with projectile masses ranging from 1·10−9 mg in spores of the fungal phyla Ascomycota and Zygomycota to approximately 10,300 mg for the ballistic tongue of the toad Bufo alvarius. The energy for shooting is generated through osmosis in fungi, plants, and animals or muscle contraction in animals. Osmosis can be induced by water condensation on the system (in fungi), or water absorption in the system (reaching critical pressures up to 15.4 atmospheres; observed in fungi, plants, and animals), or water evaporation from the system (reaching up to −197 atmospheres; observed in plants and fungi). The generated energy is stored as elastic (potential) energy in cell walls in fungi and plants and in elastic structures in animals, with two exceptions: (1) in the momentum catapult of Basidiomycota the energy is stored in a stalk (hilum) by compression of the spore and droplets and (2) in Sphagnum energy is mainly stored in compressed air. Finally, the stored energy is transformed into kinetic energy of the projectile using a catapult mechanism delivering up to 4,137 J/kg in the osmotic shooting mechanism in cnidarians and 1,269 J/kg in the muscle-powered appendage strike of the mantis shrimp Odontodactylus scyllarus. The launch accelerations range from 6.6g in the frog Rana pipiens to 5,413,000g in cnidarians, the launch velocities from 0.1 m/s in the fungal phylum Basidiomycota to 237 m/s in the mulberry Morus alba, and the launch distances from a few thousands of a millimeter in Basidiomycota to 60 m in the rainforest tree Tetraberlinia moreliana. The mass-specific power outputs range from 0.28 W/kg in the water evaporation mechanism in Basidiomycota to 1.97·109 W/kg in cnidarians using water absorption as energy source. The magnitude of accelerations involved in shooting is generally scale-dependent with the smaller the systems, discharging the microscale projectiles, generating the highest accelerations. The mass-specific power output is also scale dependent, with smaller mechanisms being able to release the energy for shooting faster than larger mechanisms, whereas the mass-specific work delivered by the shooting mechanism is mostly independent of the scale of the shooting mechanism. Higher mass-specific work-values are observed in osmosis-powered shooting mechanisms (≤ 4,137 J/kg) when compared to muscle-powered mechanisms (≤ 1,269 J/kg). The achieved launch parameters acceleration, velocity, and distance, as well as the associated delivered power output and work, thus depend on the working principle and scale of the shooting mechanism.

18 February 2016 in Bioinspiration & Biomimetics
Verified
Journal Article
Closed access
PDF file
ASAimee Sakes
Aimee Sakes
DDDimitra Dodou
Dimitra Dodou
PBPaul Breedveld
Paul Breedveld
A typical mechanical failure mode observed in slender percutaneous instruments, such as needles and guidewires, is buckling. Buckling is observed when the axial compressive force that is required to penetrate certain tissue types exceeds the critical load of the instrument and manifests itself by sudden lateral deflection of the instrument. In nature, several organisms are able to penetrate substrates without buckling while using apparatuses with diameters smaller than those of off-the-shelf available percutaneous needles and guidewires. In this study we reviewed the apparatuses and buckling prevention strategies employed by biological organisms to penetrate substrates such as wood and skin. A subdivision is made between buckling prevention strategies that focus on increasing the critical load of the penetration tool and strategies that focus on decreasing the penetration load of the substrate. In total, 28 buckling prevention strategies were identified and categorized. Most organisms appear to be using a combination of buckling prevention strategies simultaneously. Integration and combination of these biological buckling prevention strategies in percutaneous instruments may contribute to increasing the success rate of percutaneous interventions.

29 September 2024 in Advanced Intelligent Systems
Verified
Journal Article
Open access
VKVera Gesina Kortman
Vera Gesina Kortman
BMBarbara Mazzolai
Barbara Mazzolai
ASAimee Sakes
Aimee Sakes
JJJovana Jovanova
Jovana Jovanova
Engineers frequently aim to streamline environmental factors to facilitate the effective operation of robots. However, in nature, environmental considerations play a crucial role in shaping the embodiment of organisms. To comply robots with the complexity of real‐world environments, embedding similar intelligence is key. In the field of soft robotics, various approaches offer insight into how intelligence can be integrated into artificial agents. A discussed topic is the intricate relationship between the brain and the body at the core of intelligence in robots. The goal of this article is, therefore, to unravel the strategies to implement different types of intelligence currently adopted in soft robots. A classification is made by making a distinction between agents that adapt to their environment by 1) their adaptive shape, 2) their adaptive functionality, and 3) their adaptive mechanics. Additionally, the perspectives on intelligence based on their computational approach are distinguished: centralized computation, decentralized computation, or embedded computation. It is concluded that a tailored robotic design approach attuned to specific environmental demands is needed. To unlock the full potential of soft robots, a fresh perspective on embodied intelligence is described, so‐called mechanical intelligence, emphasizing the robot's responsiveness to changing external conditions of a real‐world environment.

20 December 2021 in Materials
Verified
Journal Article
Open access
PDF file
CCCostanza Culmone
Costanza Culmone
KLKirsten Lussenburg
Kirsten Lussenburg
JAJoost Alkemade
Joost Alkemade
GSGerwin Smit
Gerwin Smit
ASAimee Sakes
Aimee Sakes
PBPaul Breedveld
Paul Breedveld
In the field of medical instruments, additive manufacturing allows for a drastic reduction in the number of components while improving the functionalities of the final design. In addition, modifications for users’ needs or specific procedures become possible by enabling the production of single customized items. In this work, we present the design of a new fully 3D-printed handheld steerable instrument for laparoscopic surgery, which was mechanically actuated using cables. The pistol-grip handle is based on ergonomic principles and allows for single-hand control of both grasping and omnidirectional steering, while compliant joints and snap-fit connectors enable fast assembly and minimal part count. Additive manufacturing allows for personalization of the handle to each surgeon’s needs by adjusting specific dimensions in the CAD model, which increases the user’s comfort during surgery. Testing showed that the forces on the instrument handle required for steering and grasping were below 15 N, while the grasping force efficiency was calculated to be 10–30%. The instrument combines the advantages of additive manufacturing with regard to personalization and simplified assembly, illustrating a new approach to the design of advanced surgical instruments where the customization for a single procedure or user’s need is a central aspect.

5 April 2022 in European Spine Journal
Verified
Journal Article
Open access
PDF file
EKEsther P. de Kater
Esther P. de Kater
ASAimee Sakes
Aimee Sakes
EEErik Edström
Erik Edström
AEAdrian Elmi-Terander
Adrian Elmi-Terander
GKGerald Kraan
Gerald Kraan
PBPaul Breedveld
Paul Breedveld
Purpose: This review provides an overview of the patent literature on posteriorly placed intrapedicular bone anchors. Conventional pedicle screws are the gold standard to create a fixation in the vertebra for spinal fusion surgery but may lack fixation strength, especially in osteoporotic bone. The ageing population demands new bone anchors that have an increased fixation strength, that can be placed safely, and, if necessary, can be removed without damaging the surrounding tissue.Methods: The patent search was conducted using a classification search in the Espacenet patent database. Only patents with a Cooperative Patent Classification of A61B17/70 or A61B17/7001 concerning spinal positioners and stabilizers were eligible for inclusion. The search query resulted in the identification of 731 patents. Based on preset inclusion criteria, a total of 56 unique patents on different anchoring methods were included, reviewed and categorized in this study.Results: Five unique fixation methods were identified; (1) anchors that use threading, (2) anchors that utilize a curved path through the vertebra, (3) anchors that (partly) expand, (4) anchors that use cement and (5) anchors that are designed to initiate bone ingrowth. Of the anchor designs included in this study, eight had a corresponding commercial product, six of which were evaluated in clinical trials.Conclusion: This review provides insights into worldwide patented intrapedicular bone anchors that aim to increase the fixation strength compared to the conventional pedicle screw. The identified anchoring methods and their working principles can be used for clinical decision-making and as a source of inspiration when designing novel bone anchors.

10 May 2023 in Bioinspiration & Biomimetics
Verified
Journal Article
Open access
VKVera G Kortman
Vera G Kortman
ASAimee Sakes
Aimee Sakes
GEGen Endo
Gen Endo
PBPaul Breedveld
Paul Breedveld
Gripping slippery and flexible tissues during minimal invasive surgery (MIS) is often challenging using a conventional tissue gripper. A force grip has to compensate for the low friction coefficient between the gripper’s jaws and the tissue surface. This study focuses on the development of a suction gripper. This device applies a pressure difference to grip the target tissue without the need to enclose it. Inspiration is taken from biological suction discs, as these are able to attach to a wide variety of substrates, varying from soft and slimy surfaces to rigid and rough rocks. Our bio-inspired suction gripper is divided into two main parts: (1) the suction chamber inside the handle where vacuum pressure is generated, and (2) the suction tip that attaches to the target tissue. The suction gripper fits through a ∅ 10 mm trocar and unfolds in a larger suction surface when being extracted. The suction tip is structured in a layered manner. The tip integrates five functions in separate layers to allow for safe and effective tissue handling: (1) foldability, (2) air-tightness, (3) slideability, (4) friction magnification and (5) seal generation. The contact surface of the tip creates an air-tight seal with the tissue and enhances frictional support. The suction tip’s shape grip allows for the gripping of small tissue pieces and enhances its resistance against shear forces. The experiments illustrated that our suction gripper outperforms man-made suction discs, as well as currently described suction grippers in literature in terms of attachment force ( 5.95 ± 0.52 N on muscle tissue) and substrate versatility. Our bio-inspired suction gripper offers the opportunity for a safer alternative to the conventional tissue gripper in MIS.