Henrik Frisk

Mr. Henrik Frisk

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
HFHenrik Frisk
Henrik Frisk
ELEliza Lindqvist
Eliza Lindqvist
OPOscar Persson
Oscar Persson
JWJuliane Weinzierl
Juliane Weinzierl
LBLinda K. Bruetzel
Linda K. Bruetzel
AEAdrian Elmi-Terander
Adrian Elmi-Terander
Background: To investigate the accuracy of augmented reality (AR) navigation using the Magic Leap head mounted device (HMD), pedicle screws were minimally invasively placed in four spine phantoms. Methods: AR navigation provided by a combination of a conventional navigation system integrated with the Magic Leap head mounted device (AR-HMD) was used. Forty-eight screws were planned and inserted into Th11-L4 of the phantoms using the AR-HMD and navigated instruments. Postprocedural CT scans were used to grade the technical (deviation from the plan) and clinical (Gertzbein grade) accuracy of the screws. The time for each screw placement was recorded. Results: The mean deviation between navigation plan and screw position was 1.9 ± 0.7 mm (1.9 [0.3–4.1] mm) at the entry point and 1.4 ± 0.8 mm (1.2 [0.1–3.9] mm) at the screw tip. The angular deviation was 3.0 ± 1.4° (2.7 [0.4–6.2]°) and the mean time for screw placement was 130 ± 55 s (108 [58–437] s). The clinical accuracy was 94% according to the Gertzbein grading scale. Conclusion: The combination of an AR-HMD with a conventional navigation system for accurate minimally invasive screw placement is feasible and can exploit the benefits of AR in the perspective of the surgeon with the reliability of a conventional navigation system.

20 February 2024 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Open access
PDF file
HFHenrik Frisk
Henrik Frisk
GBGustav Burström
Gustav Burström
OPOscar Persson
Oscar Persson
VEVictor Gabriel El-Hajj
Victor Gabriel El-Hajj
LCLuisa Coronado
Luisa Coronado
AEAdrian Elmi-Terander
Adrian Elmi-Terander
Introduction: Spinal navigation solutions have been slower to develop compared to cranial ones. To facilitate greater adoption and use of spinal navigation, the relatively cumbersome registration processes need to be improved upon. This study aims to validate a new solution for automatic image registration and compare it to a traditional Surface Matching method. Method: Adult patients undergoing spinal surgery requiring navigation were enrolled after providing consent. A registration matrix—Universal AIR (= Automatic Image Registration)—was placed in the surgical field and used for automatic registration based on intraoperative 3D imaging. A standard Surface Matching method was used for comparison. Accuracy measurements were obtained by comparing planned and acquired coordinates on the vertebrae. Results: Thirty-nine patients with 42 datasets were included. The mean accuracy of Universal AIR registration was 1.20 ± 0.42 mm, while the mean accuracy of Surface Matching registration was 1.94 ± 0.64 mm. Universal AIR registration was non-inferior to Surface Matching registration. Post hoc analysis showed a significantly greater accuracy for Universal AIR registration. In Surface Matching, but not automatic registration, user-related errors such as incorrect identification of the vertebral level were seen. Conclusion: Automatic image registration for spinal navigation using Universal AIR and intraoperative 3D imaging provided improved accuracy compared to Surface Matching registration. In addition, it minimizes user errors and offers a standardized workflow, making it a reliable registration method for navigated spinal procedures.

18 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
HFHenrik Frisk
Henrik Frisk
MJMargret Jensdottir
Margret Jensdottir
LCLuisa Rojas Coronado
Luisa Rojas Coronado
MCMarkus Conrad
Markus Conrad
Susanne HagerSusanne Hager
Susanne Hager
OPOscar Persson
Oscar Persson
Objective: The precision of neuronavigation systems relies on the correct registration of the patient’s position in space and aligning it with radiological 3D imaging data. Registration is usually performed by the acquisition of anatomical landmarks or surface matching based on facial features. Another possibility is automatic image registration using intraoperative imaging. This could provide better accuracy, especially in rotated or prone positions where the other methods may be difficult to perform. The aim of this study was to validate automatic image registration (AIR) using intraoperative cone-beam computed tomography (CBCT) for cranial neurosurgical procedures and compare the registration accuracy to the traditional surface matching (SM) registration method based on preoperative MRI. The preservation of navigation accuracy throughout the surgery was also investigated. Methods: Adult patients undergoing intracranial tumor surgery were enrolled after consent. A standard SM registration was performed, and reference points were acquired. An AIR was then performed, and the same reference points were acquired again. Accuracy was calculated based on the referenced and acquired coordinates of the points for each registration method. The reference points were acquired before and after draping and at the end of the procedure to assess the persistency of accuracy. Results: In total, 22 patients were included. The mean accuracy was 6.6 ± 3.1 mm for SM registration and 1.0 ± 0.3 mm for AIR. The AIR was superior to the SM registration (p < 0.0001), with a mean improvement in accuracy of 5.58 mm (3.71–7.44 mm 99% CI). The mean accuracy for the AIR registration pre-drape was 1.0 ± 0.3 mm. The corresponding accuracies post-drape and post-resection were 2.9 ± 4.6 mm and 4.1 ± 4.9 mm, respectively. Although a loss of accuracy was identified between the preoperative and end-of-procedure measurements, there was no statistically significant decline during surgery. Conclusions: AIR for cranial neuronavigation consistently delivered greater accuracy than SM and should be considered the new gold standard for patient registration in cranial neuronavigation. If intraoperative imaging is a limited resource, AIR should be prioritized in rotated or prone position procedures, where the benefits are the greatest.

13 February 2024 in Acta Neurochirurgica
Verified
Journal Article
Open access
PDF file
MKMagnus Kaijser
Magnus Kaijser
HFHenrik Frisk
Henrik Frisk
OPOscar Persson
Oscar Persson
GBGustav Burström
Gustav Burström
ASAnnika Suneson
Annika Suneson
AEAdrian Elmi-Terander
Adrian Elmi-Terander
Background: The current shortage of radiology staff in healthcare provides a challenge for departments all over the world. This leads to more evaluation of how the radiology resources are used and a demand to use them in the most efficient way. Intraoperative MRI is one of many recent advancements in radiological practice. If radiology staff is performing intraoperative MRI at the operation ward, they may be impeded from performing other examinations at the radiology department, creating costs in terms of exams not being performed. Since this is a kind of cost whose importance is likely to increase, we have studied the practice of intraoperative MRI in Sweden. Methods: The study includes data from the first four hospitals in Sweden that installed MRI scanners adjacent to the operating theaters. In addition, we included data from Karolinska University Hospital in Solna where intraoperative MRI is carried out at the radiology department. Results: Scanners that were moved into the operation theater and doing no or few other scans were used 11–12% of the days. Stationary scanners adjacent to the operation room were used 35–41% of the days. For scanners situated at the radiology department doing intraoperative scans interspersed among all other scans, the proportion was 92%. Conclusion: Our study suggests that performing exams at the radiology department rather than at several locations throughout the hospital may be an efficient approach to tackle the simultaneous trends of increasing demands for imaging and increasing staff shortages at radiology departments.

24 October 2025 in Acta Neurochirurgica
Verified
Journal Article
Open access
PDF file
HFHenrik Frisk
Henrik Frisk
GMGayane Margaryan
Gayane Margaryan
ABAli Buwaider
Ali Buwaider
DSDavit Sargsyan
Davit Sargsyan
VEVictor Gabriel El-Hajj
Victor Gabriel El-Hajj
AEAdrian Elmi-Terander
Adrian Elmi-Terander
Objective: Gross total resection is strived for in intramedullary spinal cord lesion surgery. Intraoperative neurophysiological monitoring (IONM) is the gold standard, but there is no consensus on the optimal IONM workflow. This study details our institutional workflow. Methods: We retrospectively reviewed all adults who underwent intramedullary resection at Karolinska University Hospital, 2007–2021 ( n = 70). Continuous multimodal IONM (somatosensory-evoked potentials (SSEP), motor-evoked potentials (MEP) and epidural D-waves) was conducted by an in-room neurophysiologist. Alarm thresholds were preset (≥ 50% SSEP amplitude drop/10% latency rise; ≥ 80% MEP reduction; ≥ 50% D-wave loss) and triggered a standardized four-step rescue protocol (halt manipulation, raise MAP to 80–90 mm Hg, topical papaverine, observation). Motor/sensory function, modified McCormick (mMC) grade, pain, and sphincter control were documented pre-operatively, at 3 months, and ≥ 12 months. Results: Seventy patients were included. Most harboured ependymoma (51%), hemangioblastoma (18%) and cavernoma (8.5%). A neurophysiologist was present during every procedure. A ≥ 50% intra-operative SSEP-amplitude decrease was not followed by a sensory deficit (OR:3.0, 95% CI 0.86–10.6; p = 0.085) or mMC deterioration (OR:1.6, 0.33–7.5; p = 0.57) at either short- or long-term follow-up. In contrast, complete SSEP loss markedly increased the risk of postoperative sensory deficit (3-months-OR:25.2, 4.7–135; p < 0.001; long-term-OR 11.0, 2.8–43.8; p < 0.001) and poorer mMC grade (3-months-OR:7.8, 2.0–31; p = 0.004; long-term-OR:11.0, 2.8–43.8; p < 0.001). Loss of MEPs predicted a decline in mMC at long-term follow-up (OR:4.0, 1.06–15.1; p = 0.041). Conclusions: Live data from continuous intraoperative neurophysiological monitoring, expertly interpreted in the OR, could potentially be used to make surgical and anesthesiologic adjustments with the goal of minimizing the risk of negative neurological outcomes. Significant associations were found between decreased or lost IONM signals and poorer sensorimotor function and mMC score at short- and long-term follow-up. Implementation of the IONM workflow is suggested in all intramedullary surgery.

19 July 2021
Verified
Conference Paper
Open access
PDF file
DHDerek Holzer
Derek Holzer
HFHenrik Frisk
Henrik Frisk
AHAndre Holzapfel
Andre Holzapfel
This paper provides a study of a workshop which invited composers, musicians, and sound designers to explore instruments from the history of electronic sound in Sweden. The workshop participants applied media archaeology methods towards analyzing one particular instrument from the past, the Dataton System 3000. They then applied design fiction methods towards imagining several speculative instruments of the future. Each stage of the workshop revealed very specific utopian ideas surrounding the design of sound instruments. After introducing the background and methods of the workshop, the authors present an overview and thematic analysis of the workshop's outcomes. The paper concludes with some reflections on the use of this method-in-progress for investigating the ethics and affordances of historical electronic sound instruments. It also suggests the significance of ethics and affordances for the design of contemporary instruments.