Xiuju Li

Mr. Xiuju Li


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2026 in Remote Sensing
Verified
Journal Article
Open access
PDF file
XJXiaowei Jia
Xiaowei Jia
XLXiuju Li
Xiuju Li
TWTao Wen
Tao Wen
CHchangpei han
changpei han
Striping noise is a common problem in multi-detector scanning radiometers on remote sensing satellites, typically caused by response inconsistency among detector elements. For payloads with a multi-column redundant architecture, this paper proposes a detector-selection framework that jointly considers sensitivity and uniformity from the perspective of detector-element selection to mitigate striping noise. First, the degree of detector consistency is quantified using the Inter-Row Brightness Temperature Difference (IRBTD). Then, a dynamic programming approach based on the Viterbi algorithm is employed to select detector elements row by row with linear time complexity, optimizing the process through a weighted cost function that integrates sensitivity and consistency. Experiments on raw data from the FY-4B Geostationary High-speed Imager (GHI) show that the method reduces inconsistency by 10–40% while increasing the noise-equivalent temperature difference (NEdT) by only 1–4% (≤4 mK). The average IRBTD decreases by approximately 20–100 mK, and high-frequency striping energy is significantly suppressed (reduction of 50–90%). The algorithm exhibits linear time complexity and low computational overhead, making it suitable for real-time on-board processing. Its weighting parameter enables flexible trade-offs between sensitivity and uniformity. By suppressing striping noise directly during the detector-selection stage without introducing data distortion or requiring calibration adjustments, the proposed method can be widely applied to scanning radiometers that employ multi-column long-linear-arrays.

25 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
XSXiaolong Si
Xiaolong Si
XLXiuju Li
Xiuju Li
HCHongyao Chen
Hongyao Chen
SBShiwei Bao
Shiwei Bao
HXHeyu Xu
Heyu Xu
WHWenxin Huang
Wenxin Huang
A partial aperture onboard calibration method can solve the onboard calibration problems of some large aperture remote sensors, which is of great significance for the development trend of increasingly large apertures in optical remote sensors. In this paper, the solar diffuser reflectance degradation monitor (SDRDM) in the onboard calibration assembly (CA) of the FengYun-4 (FY-4) advanced geostationary radiance imager (AGRI) was used as the reference radiometer. It was designed for measuring the partial aperture factor (PAF) for the AGRI onboard calibration. First, the linear response count variation relationship between the two was established under the same radiance source input. Then, according to the known bidirectional reflection distribution function (BRDF) of the solar diffuser (SD) in the CA, the relative reflectance ratio coefficient between the AGRI observation direction and the SDRDM observation direction was calculated. On this basis, the response count value of the AGRI and the SDRDM was used to realize the high-precision measurement of the PAF of the AGRI B1~B3 bands by simulating the AGRI onboard calibration measurement under the illumination of a solar simulator in the laboratory. According to the determination process of the relevant parameters of the PAF, the measurement uncertainty of the PAF was analyzed; this uncertainty was greater than 2.04% and provided an important reference for the evaluation of the onboard absolute radiometric calibration uncertainty after launch.

7 March 2026 in Remote Sensing
Verified
Journal Article
Open access
PDF file
YZYining Zhu
Yining Zhu
JQJing Qian
Jing Qian
XLXiuju Li
Xiuju Li
CHchangpei han
changpei han
This study proposes a self-calibration method based on zoned reference transfer for real-time temperature monitoring of the Fengyun-4 (FY-4) Microwave Satellite payload. It aims to correct the effects of calibration coefficient degradation and instrumental background drift in uncooled infrared temperature measurement systems during on-orbit operation. The method dynamically updates the calibration reference through alternate observations of a Fixed External Blackbody and an Insertable Internal Blackbody within the field of view. Concurrently, it utilizes Masked Zone pixels to sense and compensate in real-time for the common-mode background drift caused by camera temperature variations. This approach jointly ensures long-term measurement stability and instantaneous accuracy without the need for complex scanning mechanisms. Ground validation experiments demonstrate that the proposed method suppresses background radiation drift by over 72%. Under dual-camera cross-validation, the equivalent blackbody temperature retrieval errors for low-temperature targets (230–250 K) were significantly reduced from approximately 3 K to roughly 0.4 K. Furthermore, based on a comprehensive uncertainty budget, the absolute expanded uncertainty is evaluated to be better than 0.87 K (k = 2) at 300 K. The proposed method provides a reliable and compact technical solution for high-precision infrared thermometry of moving components on-orbit.

9 January 2026 in Remote Sensing
Verified
Journal Article
Open access
PDF file
XJXiaowei Jia
Xiaowei Jia
XLXiuju Li
Xiuju Li
CHchangpei han
changpei han
New-generation geostationary meteorological satellite radiometric imagers widely employ multi-column redundant long-linear-array detectors, for which the Best Detector Selection (BDS) strategy is crucial for enhancing the quality of remote sensing data. Addressing the limitation of current BDS methods that often rely on a single metric and thus fail to fully exploit the detector’s comprehensive performance, this paper proposes a detector evaluation method based on a modified Z-score. This method systematically categorizes detector metrics into three types: positive, negative, and uniformity. It introduces, for the first time, spectral response deviation (SRD) as an effective quantitative measure for the Spectral Response Function (SRF) and employs a robust normalization strategy using the Interquartile Range (IQR) instead of standard deviation, enabling multi-dimensional detector evaluation and selection. Validation using laboratory data from the FY-4C/AGRI long-wave infrared band demonstrates that, compared to traditional single-metric optimization strategies, the best detectors selected by our method show significant improvement across multiple performance indicators, markedly enhancing both data quality and overall system performance. The proposed method features low computational complexity and strong adaptability, supporting on-orbit real-time detector optimization and dynamic updates, thereby providing reliable technical support for high-quality processing of remote sensing data from geostationary meteorological satellites.