Jianan Cui

Dr. Jianan Cui


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 August 2019 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
Jianan CuiJianan Cui
Jianan Cui
KGKuang Gong
Kuang Gong
NGNing Guo
Ning Guo
CWChenxi Wu
Chenxi Wu
XMXiaxia Meng
Xiaxia Meng
Quanzheng LiQuanzheng Li
Quanzheng Li

19 July 2021 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
Jianan CuiJianan Cui
Jianan Cui
KGKuang Gong
Kuang Gong
NGNing Guo
Ning Guo
CWChenxi Wu
Chenxi Wu
KKKyungsang Kim
Kyungsang Kim
QLQuanzheng Li
Quanzheng Li
Our study aims to improve the signal-to-noise ratio of positron emission tomography (PET) imaging using conditional unsupervised learning. The proposed method does not require low- and high-quality pairs for network training which can be easily applied to existing PET/computed tomography (CT) and PET/magnetic resonance (MR) datasets. This method consists of two steps: populational training and individual fine-tuning. As for populational training, a network was first pre-trained by a group of patients’ noisy PET images and the corresponding anatomical prior images from CT or MR. As for individual fine-tuning, a new network with initial parameters inherited from the pre-trained network was fine-tuned by the test patient's noisy PET image and the corresponding anatomical prior image. Only the last few layers were fine-tuned to take advantage of the populational information and the pre-training efforts. Both networks shared the same structure and took the CT or MR images as the network input so that the network output was conditioned on the patient’s anatomic prior information. The noisy PET images were used as the training and fine-tuning labels. The proposed method was evaluated on a 68 Ga-PPRGD2 PET/CT dataset and a 18 F-FDG PET/MR dataset. For the PET/CT dataset, with the original noisy PET image as the baseline, the proposed method has a significantly higher contrast-to noise ratio (CNR) improvement (71.85% ± 27.05%) than Gaussian (12.66% ± 6.19%, P = 0.002), nonlocal mean method (22.60% ± 13.11%, P = 0.002) and conditional deep image prior method (52.94% ± 21.79%, P = 0.0039). For the PET/MR dataset, compared to Gaussian (18.73% ± 9.98%, P < 0.0001), NLM (26.01% ± 19.40%, P < 0.0001) and CDIP (47.48% ± 25.36%, P < 0.0001), the CNR improvement ratio of the proposed method (58.07% ± 28.45%) is the highest. In addition, the denoised images using both datasets also showed that the proposed method can accurately restore tumor structures while also smoothing out the noise.