To meet 2010 emission targets, optimal SCR system performance is required. In addition, attention has to be paid to in-use compliance requirements. Closed-loop control seems an attractive option to meet the formulated goals. This study deals with the potential and limitations of closed-loop SCR control. High NOx conversion in combination with acceptable NH3 slip can be realized with an open-loop control strategy. However, closed-loop control is needed to make the SCR system robust for urea dosage inaccuracy, catalyst ageing and NOx engine-out variations. Then, the system meets conformity of production and in-use compliance norms. To demonstrate the potential of closed-loop SCR control, a NOx sensor based control strategy with cross-sensitivity compensation is compared with an adaptive surface coverage/NH3 slip control strategy and an open-loop strategy. The adaptive surface coverage/NH3 slip control strategy shows best performance over simulated ESC and ETC cycles. SCR catalyst dynamics, time delay in the urea injection and maximum NH3 slip targets limit the performance of closed-loop SCR control. If new reagent dosage systems and future catalyst technology are able to relieve these limitations, closed-loop control has the potential to reduce the calibration effort and to improve the transient control performance.
14 April 2008 in SAE International Journal of Passenger Cars - Electronic and Electrical Systems
Selective Catalytic Reduction (SCR) is the dominant solution for meeting future NOx reduction regulations for heavy-duty diesel powertrains. SCR systems benefit from closed-loop control if an appropriate exhaust gas sensor were available. An ammonia sensor has recently been developed for use as a feedback element in closed-loop control of urea dosing in a diesel SCR aftertreatment system. Closed-loop control of SCR dosing enables the SCR system to be robust against disturbances and to meet conformity of production (COP) and in-use compliance norms. The ammonia sensor is based on a non-equilibrium electrochemical principle and outputs emf signals. The sensor performs well when tested in a diesel engine exhaust environment and has minimum cross interference with CO, HC, NO, NO2, SO2, H2O and O2. Previous work, done in a simulation environment, demonstrated that an ammonia sensor provides the optimal feedback for urea dosing control algorithms in closed-loop SCR systems. A model-based SCR control strategy deploying an ammonia feedback sensor demonstrated high NOx conversion, low NH3 slip and good robustness against disturbances. In this paper, FTP, ETC and ESC test data will be presented confirming these results. NOx conversions as high as 91% are measured in combination with 30% urea injection error and a 25 ppm NH3 slip constraint. Test results using the Delphi ammonia sensor for control are compared with test results utilizing a commercially available NOx sensor for control.
1 April 2014 in SAE International Journal of Advances and Current Practices in Mobility
Premixed combustion concepts like PCCI and RCCI have attracted much attention, since these concepts offer possibilities to reduce engine out emissions to a low level, while still achieving good efficiency. Most RCCI studies use a combination of a high-cetane fuel like diesel, and gasoline as low-cetane fuel. Limited results have been published using natural gas as low-cetane fuel; especially full scale engine results. This study presents results from an experimental study of diesel-CNG RCCI operation on a 6 cylinder, 8 l heavy duty engine with cooled EGR. This standard Tier4f diesel engine was equipped with a gas injection system, which used single point injection and mixed the gaseous fuel with air upstream of the intake manifold. For this engine configuration, RCCI operating limits have been explored. In the 1200-1800 rpm range, RCCI operation with Euro-VI engine out NOx and soot emissions was achieved between 2 and 9 bar BMEP without EGR. Corresponding hydrocarbon levels were high, but exhaust temperature levels hold promise for a suitable reduction through catalytic aftertreatment. Thermal efficiency was comparable to or better than diesel operation. In the load ranges tested, gas Methane Number (MN) variations between 70 and 100 have only a small effect on RCCI performance.
8 March 2004 in SAE International Journal of Advances and Current Practices in Mobility
In the past decade, SCR deNOx technology with urea injection has grown to maturity. European OEMs will apply SCR deNOx to meet future heavy-duty emissions legislation starting with EURO-4 (2005/2006). Numerous research programs in Europe and the US have shown a variety of system layouts and control strategies. The main differences are formed by: the engine-out NOx calibration the application of an NO to NO2 catalyst open-loop or closed-loop urea dosage control. This paper gives an overview of possible SCR system configurations that are required for different stages of future emission legislation. Engine-out NOx emission is strongly influenced by ambient conditions. Projections in this study show that a combination of cold climate and a wintergrade fuel is the most severe: it may lead to 30% lower engine-out NOx emission with respect to laboratory conditions. The varying engine-out NOx emission requires a safety margin in the case of an open-loop controlled system in order to avoid excessive NH3 slip. Calculations in this paper show that Euro 4 limits can be met with open-loop controlled urea dosage; an NO to NO2 catalyst is even not required. For other future emission legislation (Euro 5, US 2007 and US 2010), it becomes difficult to safely achieve the limits with open-loop control. US 2007 and 2010 legislation require an NO to NO2 catalyst because of the low average load and consequently low exhaust gas temperatures. Engines that are developed to meet US 2010 legislation need special measures to increase the exhaust gas temperature and to reduce engine-out NOx below 2 g/kWh. In all cases, optimal hydrolysis and mixing conditions are of major importance. High speed photography and droplet size measurements are presented as methods for characterizing and modeling aqueous urea spray patterns. The information from these measurements is used as input parameters for simulation tools. These consist of a 2D/3D CFD program for urea mixing analysis and a 1D SCR system model for development of dosage control and optimization of catalyst dimension. Finally, simulations with the SCR system model are compared with measurements on the engine test bench.
12 April 2010 in SAE International Journal of Advances and Current Practices in Mobility
This paper presents a cylinder pressure-based control (CPBC) system for conventional diesel combustion with high EGR levels. Besides the commonly applied heat release estimation, the CPBC system is extended with a new virtual NOx and PM sensor. Using available cylinder pressure information, these emissions are estimated using a physically based combustion model. This opens the route to advanced On-Board Diagnostics and to optimized fuel consumption and emissions during all operating conditions.The potential of closed-loop CA50 and IMEP control is demonstrated on a multi-cylinder heavy-duty EGR engine. For uncalibrated injectors and fuel variations, the combustion control system makes the engine performance robust for the applied variations and reduces the need for a time-consuming calibration process. Cylinder balancing is shown to enable auto-calibration of fuel injectors and to enhance fuel flexibility. For both Biodiesel and US diesel, the effects on NOx and PM emissions are partly compensated for by combined CA50 and IMEP control. This can be further improved by application of (virtual) emission sensors. Furthermore, it is shown that this combustion controller shows good transient performance during load changes.The virtual emission sensor is successfully implemented for real-time control. For operating conditions with high EGR rates and varying injection timing, the predictions of the virtual NOx and PM sensor are compared with measurements. NOx emission prediction inaccuracy is typically on the order of 12%, which is comparable to commercially available sensors. The predicted PM emissions show good qualitative agreement, but need further improvement for application in DPF regeneration and PM emission control strategies. Robust emission control is essential to meet future requirements for On-Board Diagnostics and In-Use Compliance.