Monitoring of the interface temperature at skin level in lower-limb prosthesis is notoriously complicated. This is due to the flexible nature of the interface liners used impeding the required consistent positioning of the temperature sensors during donning and doffing. Predicting the in-socket residual limb temperature by monitoring the temperature between socket and liner rather than skin and liner could be an important step in alleviating complaints on increased temperature and perspiration in prosthetic sockets. In this work, we propose to implement an adaptive neuro fuzzy inference strategy (ANFIS) to predict the in-socket residual limb temperature. ANFIS belongs to the family of fused neuro fuzzy system in which the fuzzy system is incorporated in a framework which is adaptive in nature. The proposed method is compared to our earlier work using Gaussian processes for machine learning. By comparing the predicted and actual data, results indicate that both the modeling techniques have comparable performance metrics and can be efficiently used for non-invasive temperature monitoring.
1 December 1997 in Prosthetics and Orthotics International
Force sensing resistors (FSR) have been used to measure dynamic pressures at the interface between appliance and patient. Inaccuracies using FSRs have been reported. This paper summarises both the calibration problems encountered and the techniques adopted to minimise inaccuracies. It is considered that, by calibrating the transducers attached to the socket, and by adopting a strict test protocol, FSRs may provide a guide to the dynamic pressure distribution applied to the trans-tibial stump during gait.
1 October 2013 in Prosthetics and Orthotics International
Disability is inextricably linked to poverty. A total of 80% of the disabled population lives in low-income countries. The demand for prosthetic and orthotic services in these countries is increasing, and a variety of methods to provide services are currently used. To assess current models of provision to facilitate sustainable, evidence-based prosthetic and orthotic services. Literature review. A literature search was performed through Medline (Ovid), PubMed, ISI Web of Knowledge, EMBASE and RECAL Legacy using combinations of subject heading and text word searching strategies. Full-text publications were critically appraised and ranked according to the Scottish Intercollegiate Guidelines Network guidelines. Three areas were deemed pertinent to the research question. Studies were grouped into one or more of these categories based on the issues addressed: instigators, types of service provision, demographics and region-specific issues. It was found that many complex factors influence prosthetic and orthotic services in low-income countries. Demographic and regional idiosyncrasies require prosthetic and orthotic services to be tailored to address the specific needs of individual countries. The lack of and quality of available research made efficacy of methods used to provide services in low-income countries difficult to determine. This review aims to highlight areas of best practice in prosthetic and orthotic services in low-income countries and to show where further research is required in order to develop evidence-based prosthetic and orthotic services.
1 August 1999 in Prosthetics and Orthotics International
Force sensing resistors (FSR) have been used to measure dynamic stump/socket interface pressures during the gait of a trans-tibial amputee. A total of 350 pressure sensors were attached to the inner wall of a hydrocast socket. Data were sampled at 150Hz during approximately 0.8 seconds of prosthetic stance of gait. The dynamic pressure distributions within a hand cast socket reported by Convery and Buis (1998) are compared with those monitored within a hydrocast socket for the same amputee. The pressure gradients within the hydrocast socket are less than that of the hand cast Patellar-Tendon-Bearing (PTB) socket. The proximal “ring” of high pressure in the hand cast PTB socket is replaced with a more distal pressure in the hydrocast socket.
Prosthetic alignment, positioning of a prosthetic foot relative to a socket, is an iterative process in which an amputee’s gait is optimized through repetitive optical gait observation and induction of alignment adjustments when deviations are detected in spatiotemporal and kinematic gait parameters. An important limitation of the current prosthetic alignment approach is the subjectivity and the lack of standardized quantifiable baseline values. The purpose of this systematic review is to investigate if an optimal alignment criterion can be derived from published articles. Moreover, we investigated the effect of alignment changes on spatiotemporal, kinematic and kinetic gait parameters. A total of 11 studies were included, two controlled before-and-after studies and nine-interrupted time series studies. The results demonstrate that alignment changes have a predictable influence on the included kinetic parameters. However, the effect of alignment changes on spatio-temporal and kinematic gait parameters are generally unpredictable. These findings suggest that it is imperative to include kinetics in the process of dynamic prosthetic alignment. Partially this can be established by communication with the prosthetic user in terms of perceived socket comfort, but the use of measurement tools should also be considered. While current literature is not conclusive about an optimal alignment, future alignment research should focus on alignment optimisation based on kinetic outcomes.
7 November 2014 in IEEE Journal of Biomedical and Health Informatics
Increased temperature and perspiration within a prosthetic socket is a common complaint of many amputees. The heat dissipation in prosthetic sockets is greatly influenced by the thermal conductive properties of the socket and interface liner materials. These materials influence the body's temperature regulation mechanism and might be the reason for thermal discomfort in prosthetic sockets. Monitoring interface temperature at skin level is notoriously complicated. The problem might be considered notorious because embedding wires and sensors in an elastomer eventually results in elastomer failures because of the high strain induced when donning a liner (amputees roll the liners onto their limbs). Another reason is because placing sensors and wires directly against the skin could cause irritation and chaffing over just a short period of time. We describe a route wherein if the thermal properties of the socket and liner materials are known, the in-socket residual limb temperature could be accurately predicted by monitoring the temperature between socket and liner rather than skin and liner using the Gaussian process technique.